Absorbable Multifilament PGA Prime Suture | 100% Polyglycolic Acid | Needle ½ Circle Triangular Point Reverse Cutting HS 40 mm | Gauge USP 2/0 (Metric 3) | Violet Thread 70 cm | Box of 12 units | Ref. AMP118HS4020

Original price was: 39,90 €.Current price is: 32,60 €.

Synthetic absorbable suture 100% polyglycolic acid (PGA) in Prime quality, presented as a violet-coloured grooved braided multifilament with a coating of polycaprolactone and calcium stearate. It mounts a ½ circle needle with triangular body and point of reverse cutting (Reverse Cutting) of 40 mm (HS 40), USP 2/0 (metric 3) gauge and 70 cm thread. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterile by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures and general surgery. Ref. AMP118HS4020. Price per box of 12 units, minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP118HS4020

Description

1. Commercial Introduction

The absorbable multifilament PGA Prime suture, reference AMP118HS4020, is the reference solution in the operating theatre for professionals seeking a synthetic absorbable thread with reliable, predictable, high-quality performance in the approximation of soft tissues, ligatures and general surgery. Its ½ circle needle with reverse cutting triangular point of 40 mm (HS 40) penetrates firm, dense tissues with controlled trauma, while the 70 cm violet fluted thread ensures optimal visibility of the surgical field and excellent handling in every stitch.

Manufactured under strict quality standards for the B2B channel, it combines minimal tissue reaction, excellent tensile strength and optimal knot security. Commercial presentation in a box of 12 units with a minimum order of 30 boxes, ideal for the continuous supply of hospitals, private clinics and purchasing centres.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish. Its coating of polycaprolactone and calcium stearate improves thread glide through tissue, reduces friction and facilitates firm, secure knot tying, even in fine-to-medium diameter gauges such as USP 2/0 (metric 3).

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. This profile makes it suitable for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.

The ½ circle needle with triangular body and reverse cutting point of 40 mm is designed to penetrate firm, consistent tissues without tearing —skin, fascia, aponeurosis, abdominal wall—, and its ½ curvature facilitates work in deep planes and closed surgical fields. The product is supplied sterile by ethylene oxide (EO), single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference AMP118HS4020

Parameter Specification
Reference (SKU Cahnos) AMP118HS4020
Range / quality Prime (premium multifilament range)
Composition 100% polyglycolic acid (PGA) absorbable by hydrolysis
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2/0 (metric 3)
Thread colour Violet (also available undyed in the range)
Thread length 70 cm
Needle shape ½ circle (approx. 180°)
Tip type Triangular with reverse cutting (Reverse Cutting), body and point
Needle size HS 40 (40 mm), 1 needle per thread
Absorption mechanism Hydrolysis, between 60 and 90 days
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile sachets)
Minimum order 30 boxes
Regulatory standard USP / European Pharmacopoeia

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75% of the initial strength
3 weeks 50% of the initial strength
4 weeks 40% of the initial strength
Complete absorption 60-90 days by hydrolysis

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.

4. Equivalences and Cross-References

Polyglycolic acid (PGA) braided multifilament coated with medium absorption (60-90 days) is one of the most widespread synthetic absorbables on the market. This reference shares the absorption profile, coated braided structure, USP 2/0 gauge, HS 40 mm ½ circle reverse cutting needle and 70 cm length with the main homologous families of absorbable braided suture. Comparison with polymers other than PGA homopolymer is made at category level and is not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson) Coated VICRYL® (braided polyglactin 910, violet, ½ circle reverse cutting needle CP-40 mm, USP 2/0, 70 cm) J478H Comparable by category (not interchangeable 1:1) Same needle configuration (CP 40 mm reverse cutting), USP 2/0 gauge, violet and 70 cm; copolymer composition 90/10 glycolide/L-lactide versus PGA homopolymer, with declared absorption of 56-70 days. Code verified in authorised distributor sources; consult the manufacturer’s data sheet before substituting in tenders.
Ethicon (Johnson & Johnson) Coated VICRYL® Plus Antibacterial (polyglactin 910, ½ circle reverse cutting needle CP-40 mm, USP 2/0, violet, 70 cm) VCP478H Comparable by category (not interchangeable 1:1) Same needle geometry and gauge as the current product; incorporates antibacterial coating (triclosan) and copolymer composition with shorter absorption. Verify IFU before formal substitution.

Other commercial houses with homologous families of medium-absorption absorbable braided suture —B. Braun with its Safil® line, Medtronic with the Polysorb® range and SMI with Surgicryl®— offer products of the same clinical category, but no reference code confirmed against an official source is available for this exact configuration (USP 2/0 / HS 40 mm / 70 cm). There is no manufacturer-validated equivalence table cross-referencing this specific reference with closed codes from other brands; consult the technical department of Cahnos before use in tenders.

Within the Cahnos catalogue, the closest alternative in composition is reference P1L18HS4020 (polyglactin 910 Prime, same HS 40 mm needle, USP 2/0, violet and 70 cm), with an absorption profile of 56-72 days.

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the gauge according to the anatomical area. USP 2/0 (metric 3) is very versatile: it is indicated for tissues with moderate tension —skin, subcutaneous tissue, mucosa, fascia and soft tissue in general—, as well as for ligatures and closures in general and digestive surgery. The reverse cutting triangular point (HS) is recommended for penetrating firm, dense tissues without tearing (skin, fascia); if the tissue is soft or friable, consider the conical point variant (HR).

Reference Variant of interest
AMP118HS4020 PGA Prime USP 2/0, triangular HS 40 mm needle, violet, 70 cm (current product)
AM118HS4020 PGA standard range USP 2/0, same HS 40 mm needle, violet, 70 cm (economical alternative)
AMP118HS4010 PGA Prime USP 0, same HS 40 mm needle, violet, 70 cm (slightly larger gauge)
AMP118HS4001 PGA Prime USP 1, same HS 40 mm needle, violet, 70 cm (higher initial strength)
AMP118HR4010 PGA Prime USP 0, cylindrical HR 40 mm needle with conical point, violet, 70 cm (more atraumatic)
P1L18HS4020 PGLA Prime USP 2/0, triangular HS 40 mm needle, violet, 70 cm (alternative polymer, absorption 56-72 days)

All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, hospital supply contracts or equivalents from other commercial houses, contact our technical-commercial team.

Additional information

Reference

AMP118HS4020

Material

100% polyglycolic acid (PGA)

Thread structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2/0 (metric 3)

Tip type

Triangular reverse cutting (Reverse Cutting)

Needle size

HS 40 (40 mm)

Absorption mechanism

Hydrolysis (60-90 days)

Sterilisation

Ethylene oxide (EO), single-use

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HS 40

Usp

2/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime