Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture is the technical reference for prolonged absorption for the professional who needs sustained wound support, predictable handling and maximum knot security. This presentation combines a non-grooved violet thread of 70 cm in USP 4/0 gauge with a straight needle with triangular point and conventional cutting edge of 60 mm (GS60), the classic straight needle geometry for manual suturing of accessible planes, with a clean and controlled passage through tissue.
It is the B2B supply solution for operating theatres, general surgery departments, paediatric cardiovascular surgery units and hospital purchasing centres seeking quality consistency with CE marking. Synthetic absorbable medical device, sterile and single-use, supplied in a box of 12 units.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polyester —poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals, completing between 180 and 210 days. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.
The straight needle with triangular cross-section and conventional cutting edge has the cutting edge on the inner face of the curve —in this case, being straight, the triangular body traverses fibrous tissues such as skin, subcutaneous tissue, aponeurosis and fascia with a direct passage and without the need for a curved needle holder. With a length of 60 mm (GS60) and USP 4/0 gauge, this configuration is commonly used in manual approximation sutures and ligatures. The violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Non-grooved monofilament |
| Gauge / size | USP 4/0 |
| Thread colour | Violet (high visibility), non-barbed |
| Thread length | 70 cm |
| Needle shape | Straight |
| Needle body and point | Triangular, conventional cutting point |
| Needle size | GS60 – 60 mm, 1 needle per thread |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues |
| Presentation | Box of 12 sterile units |
| Factory reference / SKU | 418GS6040 / AM418GS6040 |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis, with minimal tissue reaction |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of planes subjected to sustained traction and in procedures requiring prolonged support.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (straight cutting needle of 60 mm, USP 4/0 gauge, 70 cm thread), the following commercial references from other manufacturers have been compared in official catalogues and authorised distributors:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone) monofilament, KS straight 60 mm cutting needle | Z662H | Comparable by category (not interchangeable 1:1) | Same general configuration: PDO monofilament material, straight cutting needle of 60 mm (KS), USP 4/0 gauge and 70 cm thread (27\”). Difference: colourless thread compared with the violet of this reference and commercial presentation (box of 36 units). Confirmed in Ethicon catalogue and authorised distributors. |
| Ethicon (Johnson & Johnson MedTech) | PDS Plus® Antibacterial (polydioxanone) monofilament, KS straight 60 mm cutting needle | PDP662H | Comparable by category (not interchangeable 1:1) | Same KS straight cutting needle configuration of 60 mm, USP 4/0 gauge and 70 cm thread. Difference: colourless thread, antibacterial triclosan coating (indicated only where its use is approved) and its own needle nomenclature. Confirmed in Ethicon catalogue and authorised distributors. |
There is no equivalence table validated by the manufacturer that officially cross-references this product with the commercial series of other brands; consult the technical department before use in tenders. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, body, point and needle size. The brands cited belong to their respective manufacturers and are mentioned only for comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue —as in this reference—, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the conventional cutting straight needle (GS) is indicated for manual sutures of accessible planes and fibrous tissues (skin, aponeurosis), while the conical point straight needle (GR) is reserved for soft and delicate tissues and the trocar point (GRT) for firm tissues of greater resistance.
Within the Cahnos catalogue, the PDO/PDS family with GS60 straight needle includes variants of interest:
| Reference | Variant of interest |
|---|---|
| P418GS6040 | Prime-quality PDO, same GS60 60 mm needle, USP 4/0, violet, 70 cm (premium range) |
| 418GS6030 | Standard PDO, same GS60 needle, USP 3/0, violet, 70 cm (finer gauge for subcutaneous tissue) |
| 418GS6020 | Standard PDO, same GS60 needle, USP 2/0, violet, 70 cm (larger gauge for soft tissue) |
| P418GS6030 | PDO Prime, GS60 needle, USP 3/0, violet, 70 cm (Prime range in fine gauge) |
All references are supplied in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.