We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone PDO/PDS Suture Prime – Straight Conventional Cutting Needle GS13 (13 mm) · USP Gauge 4/0 · Violet Thread 45 cm · Box of 12 units · Ref. AMP411GS1340

Original price was: 51,86 €.Current price is: 43,50 €.

Absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line, with a straight conventional cutting needle with triangular point, 13 mm (GS13), USP gauge 4/0 and violet non-grooved thread of 45 cm. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use, minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in a box of 12 sterile units. Ref. AMP411GS1340.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP411GS1340

Description

1. Commercial Introduction

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line is the reference choice when the operating theatre needs a suture with prolonged support, predictable behaviour and maximum knot security. This presentation combines a 45 cm violet suture in USP 4/0 gauge with a straight 13 mm needle with a conventional cutting triangular point (GS13), a precision configuration designed for ophthalmic surgery, paediatric tissues and superficial planes with direct access.

Available in a box of 12 sterile units, it is the B2B supply solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity and complete traceability in each package.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity. This guarantees a highly reproducible absorption kinetics between individuals and minimal tissue response, with complete absorption within 180 to 210 days, one of the longest support windows among absorbable sutures.

Being a non-grooved monofilament, the suture has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory reaction compared with braided sutures. The straight needle with a conventional cutting triangular point has three cutting edges that penetrate firm and fibrous tissue in a straight path, without the need to rotate the wrist; at 13 mm it is particularly practical in small, high-precision fields. The violet colour improves suture visibility on the surgical field. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference AMP411GS1340

Parameter Specification
SKU AMP411GS1340
Material Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone), non-grooved
Thread structure Monofilament, non-braided
USP / metric gauge USP 4/0 (metric 2)
Thread length 45 cm
Thread colour Violet (high visibility)
Needle shape Straight
Needle tip Triangular, conventional cutting
Needle size GS13 – 13 mm, one needle per suture
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial strength
4 weeks 60-70% of initial strength
8 weeks 45% of initial strength
Complete absorption 180-210 days by hydrolysis

This prolonged strength retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, which is why it is recommended for closures of planes subjected to sustained tension and in paediatric cardiovascular surgery where tissue growth is expected.

4. Equivalences and Cross-References

Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (straight needle with conventional cutting triangular point of 13 mm, USP 4/0 gauge, 45 cm violet suture), homologous market references have been compared in primary sources, comparable at category level and not interchangeable 1:1:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson) PDS II® (polydioxanone, monofilament), P-3 needle of 13 mm in 3/8 circle, USP 4/0, 45 cm Z494E / Z494G Comparable by category (not interchangeable 1:1) Same polymer, USP 4/0 gauge, 45 cm suture and 13 mm needle, but with a curved 3/8 circle reverse cutting needle and undyed (clear) colour, compared with the violet conventional cutting straight needle of this reference; different commercial presentation. Confirmed in Ethicon catalogue and authorised distributors.
Ethicon (Johnson & Johnson) PDS Plus® Antibacterial (polydioxanone), RB-2 needle with conical point of 13 mm, USP 4/0, 45 cm PDP9102H Comparable by category (not interchangeable 1:1) Same polymer, USP 4/0 gauge and 45 cm length, but with a Taper Point conical tip (atraumatic) compared with the conventional GS cutting of this reference, antibacterial triclosan coating and presentation in a box of 36 units.

There is no manufacturer-validated equivalence table that officially cross-references this configuration (straight GS13 conventional cutting needle, violet, 4/0) with the commercial series of other brands; consult the technical department before use in tenders. As homologous market families to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon, the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl® PDO line from SMI and the Maxon range from Medtronic (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field: USP gauge, suture length, colour, curvature, body, point and needle size. The cited brands belong to their respective manufacturers and are mentioned only for comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue, mucosa and delicate planes —as with this reference—, 3/0 and 2/0 for general soft tissue and USP 1 and above for fascia and planes under tension. Needle geometry is also decisive: the straight conventional cutting needle (GS) is indicated for precision manual suturing in accessible planes and fibrous tissues, while the straight conical-point needle (GR) is reserved for soft and delicate tissues and the trocar point (GRT) for firm tissues of greater resistance.

Within the Cahnos catalogue you will find variants of interest from the PDO/PDS family:

  • AMP418GS6040 – PDO Prime, straight GS60 needle (60 mm), USP 4/0, violet, 70 cm (long needle for accessible planes).
  • AMP418GS6030 / AMP418GS6020 – PDO Prime, straight GS60 needle, USP 3/0 and 2/0, violet, 70 cm.
  • AM418GS6040 – PDO standard quality, same GS60 configuration in 4/0.
  • AMP414GR1950-2 – PDO Prime, double straight taper-point needle 19 mm (2xGR19), USP 4/0, violet, 30 cm.
  • P1L11GS1340-2 – PGLA (polyglactin 910) multifilament, double straight GS13 needle, USP 4/0, violet, 45 cm (average absorption of 56-72 days).

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference and batch number for traceability in the operating theatre. Store in a cool, dry place, below 30 °C and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone)

Structure

Non-grooved monofilament

Gauge

USP 4/0 (metric 2)

Colour

Violet (high visibility)

Needle tip

Triangular, conventional cutting

Needle size

GS13 – 13 mm, one needle per suture

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular, ophthalmology

Presentation

Box of 12 sterile units

Medida de aguja

GS 13

Usp

4/0

Color

Violet

Medida de hilo

45 cm

Tipo de aguja

Conventional triangular

Forma de aguja

Straight, Straight Cut

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Suture Prime – Straight Conventional Cutting Needle GS13 (13 mm) · USP Gauge 4/0 · Violet Thread 45 cm · Box of 12 units · Ref. AMP411GS1340”

Your email address will not be published. Required fields are marked *