Description
1. Product Presentation
The Prime range monofilament absorbable polydioxanone (PDO/PDS) suture is the technical reference choice when the tissue requires prolonged support during healing and completely predictable absorption. This presentation combines a 75 cm violet grooved thread in USP 2/0 gauge with a ⅜ circle, cylindrical body, 20 mm Taperpoint conical point needle (DR20), an atraumatic geometry designed for soft and delicate tissues.
Available in a box of 12 sterile units, it is the B2B supply solution for operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology departments and hospital purchasing centres seeking quality homogeneity with CE marking and batch traceability.
2. Technical Explanation
Polydioxanone is an absorbable synthetic polyester —poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity, ensuring highly reproducible absorption kinetics between individuals. As a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory response compared to braided multifilament threads. Its firm feel and excellent knotting ability make it suitable for ligatures and sutures of layers under sustained tension during the critical healing phase.
The ⅜ circle needle (approx. 135° curvature) with cylindrical body and Taperpoint conical point penetrates the tissue by separating the fibres without cutting them, minimising tissue damage and making it especially suitable for well-perfused soft tissues, vessels, peritoneum and parenchyma. The USP 2/0 (metric 3) gauge is versatile: suitable for general soft tissue, superficial muscle layers, tissue approximation and ligatures. The violet grooved colour improves visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Fluted monofilament (not braided) |
| Quality / range | Prime (premium range) |
| Gauge / size | USP 2/0 (metric 3) |
| Approximate diameter | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
| Thread colour | High-visibility violet, fluted |
| Thread length | 75 cm |
| Swaged | 1 needle per pack (single strand) |
| Needle shape | 3/8 circle (approx. 135°) |
| Needle body and point | Cylindrical body, Taperpoint conical tip, atraumatic |
| Needle size | DR20 – 20 mm |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Factory reference | P412DR2020 |
| SKU Cahnos | AMP412DR2020 |
Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis, with minimal tissue reaction |
This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, therefore its use is recommended in closures of fascia, aponeurosis and structures under sustained tension.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (⅜ circle cylindrical body, 20 mm Taperpoint conical point needle, USP 2/0 gauge, 75 cm violet thread), commercial references from other manufacturers verified in primary sources are cited; all match in material (PDO monofilament) and gauge, but differ in curvature, needle measurement or thread length, therefore they are classified as comparable by category and not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone) violet monofilament | Z317H (USP 2/0, 70 cm, violet, SH needle 26 mm ½ circle taper point) | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 2/0 gauge, same violet colour and same Taperpoint conical point family. Differences: curvature (½ circle SH 26 mm vs ⅜ circle DR20 20 mm) and thread length (70 cm vs 75 cm). Confirmed in official catalogues and authorised distributors. |
| B. Braun / Aesculap | MonoPlus® (polydioxanone) uncoated monofilament, violet | C0024086 (USP 2/0 / EP 3, 70 cm, violet, HR26S ½ circle taper point needle) | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 2/0 gauge (EP 3), same violet colour and same conical point family. Differences: curvature (½ circle HR26S 26 mm vs ⅜ circle DR20 20 mm) and thread length (70 cm vs 75 cm). Confirmed in the official catalogue of B. Braun. |
There is no equivalence table validated by the manufacturer that officially cross-references this product with commercial ranges from other brands; consult with the technical department of Cahnos before use in tenders. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® line from Ethicon (Johnson \u0026 Johnson MedTech), the MonoPlus® line from B. Braun/Aesculap, the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien (polyglyconate, a different polymer, therefore its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle measurement, as well as the attachment. The cited brands belong to their respective manufacturers and are mentioned only for comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture always verify the USP gauge according to the tissue layer: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and layers under tension. Needle geometry is also decisive: the Taperpoint conical point (DR/HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma, peritoneum), while the reverse cutting triangular point (DS/HS) is used for fibrous and inelastic tissues (skin, aponeurosis, fascia).
Within the Cahnos catalogue, the PDO/PDS Prime family of ⅜ circle with taper point includes variants of interest:
| Reference | Variant of interest |
|---|---|
| AMP412DR2010 | PDO Prime, same DR20 taper point needle, USP 0, violet, 75 cm (larger gauge for layers with more tension) |
| AMP412DS2220 | PDO Prime, ⅜ circle reverse cutting triangular DS22 needle, USP 2/0, violet, 75 cm (for fibrous tissues with the same gauge) |
| AMP412HR3020 | PDO Prime, ½ circle HR30 conical point needle, USP 2/0, violet, 75 cm (greater penetration arc, same point configuration) |
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team of Cahnos.





Reviews