We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture · Needle ⅜ Circle Cylindrical Body Conical Point Taperpoint DR20 (20 mm) · USP Gauge 2/0 (Metric 3) · Violet Grooved Thread 75 cm · Ref. P412DR2020 · Box 12 units

Original price was: 51,86 €.Current price is: 44,90 €.

Prime absorbable monofilament Polydioxanone (PDO/PDS) suture with an atraumatic ⅜ circle needle, cylindrical body and 20 mm (DR20) Taperpoint conical point, USP gauge 2/0 (metric 3) and 75 cm violet grooved thread. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for soft tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Manufacturer’s ref. P412DR2020 · SKU AMP412DR2020 · Price per box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412DR2020

Description

1. Product Presentation

The Prime range monofilament absorbable polydioxanone (PDO/PDS) suture is the technical reference choice when the tissue requires prolonged support during healing and completely predictable absorption. This presentation combines a 75 cm violet grooved thread in USP 2/0 gauge with a ⅜ circle, cylindrical body, 20 mm Taperpoint conical point needle (DR20), an atraumatic geometry designed for soft and delicate tissues.

Available in a box of 12 sterile units, it is the B2B supply solution for operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology departments and hospital purchasing centres seeking quality homogeneity with CE marking and batch traceability.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polyester —poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity, ensuring highly reproducible absorption kinetics between individuals. As a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory response compared to braided multifilament threads. Its firm feel and excellent knotting ability make it suitable for ligatures and sutures of layers under sustained tension during the critical healing phase.

The ⅜ circle needle (approx. 135° curvature) with cylindrical body and Taperpoint conical point penetrates the tissue by separating the fibres without cutting them, minimising tissue damage and making it especially suitable for well-perfused soft tissues, vessels, peritoneum and parenchyma. The USP 2/0 (metric 3) gauge is versatile: suitable for general soft tissue, superficial muscle layers, tissue approximation and ligatures. The violet grooved colour improves visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

Characteristic Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Fluted monofilament (not braided)
Quality / range Prime (premium range)
Gauge / size USP 2/0 (metric 3)
Approximate diameter 0.30 – 0.349 mm (indicative according to Pharmacopoeia)
Thread colour High-visibility violet, fluted
Thread length 75 cm
Swaged 1 needle per pack (single strand)
Needle shape 3/8 circle (approx. 135°)
Needle body and point Cylindrical body, Taperpoint conical tip, atraumatic
Needle size DR20 – 20 mm
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units
Factory reference P412DR2020
SKU Cahnos AMP412DR2020

Tensile strength retention profile

Period after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis, with minimal tissue reaction

This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, therefore its use is recommended in closures of fascia, aponeurosis and structures under sustained tension.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (⅜ circle cylindrical body, 20 mm Taperpoint conical point needle, USP 2/0 gauge, 75 cm violet thread), commercial references from other manufacturers verified in primary sources are cited; all match in material (PDO monofilament) and gauge, but differ in curvature, needle measurement or thread length, therefore they are classified as comparable by category and not interchangeable 1:1:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® (polydioxanone) violet monofilament Z317H (USP 2/0, 70 cm, violet, SH needle 26 mm ½ circle taper point) Comparable by category (not interchangeable 1:1) Same PDO monofilament material, same USP 2/0 gauge, same violet colour and same Taperpoint conical point family. Differences: curvature (½ circle SH 26 mm vs ⅜ circle DR20 20 mm) and thread length (70 cm vs 75 cm). Confirmed in official catalogues and authorised distributors.
B. Braun / Aesculap MonoPlus® (polydioxanone) uncoated monofilament, violet C0024086 (USP 2/0 / EP 3, 70 cm, violet, HR26S ½ circle taper point needle) Comparable by category (not interchangeable 1:1) Same PDO monofilament material, same USP 2/0 gauge (EP 3), same violet colour and same conical point family. Differences: curvature (½ circle HR26S 26 mm vs ⅜ circle DR20 20 mm) and thread length (70 cm vs 75 cm). Confirmed in the official catalogue of B. Braun.

There is no equivalence table validated by the manufacturer that officially cross-references this product with commercial ranges from other brands; consult with the technical department of Cahnos before use in tenders. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® line from Ethicon (Johnson \u0026 Johnson MedTech), the MonoPlus® line from B. Braun/Aesculap, the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien (polyglyconate, a different polymer, therefore its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle measurement, as well as the attachment. The cited brands belong to their respective manufacturers and are mentioned only for comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture always verify the USP gauge according to the tissue layer: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and layers under tension. Needle geometry is also decisive: the Taperpoint conical point (DR/HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma, peritoneum), while the reverse cutting triangular point (DS/HS) is used for fibrous and inelastic tissues (skin, aponeurosis, fascia).

Within the Cahnos catalogue, the PDO/PDS Prime family of ⅜ circle with taper point includes variants of interest:

Reference Variant of interest
AMP412DR2010 PDO Prime, same DR20 taper point needle, USP 0, violet, 75 cm (larger gauge for layers with more tension)
AMP412DS2220 PDO Prime, ⅜ circle reverse cutting triangular DS22 needle, USP 2/0, violet, 75 cm (for fibrous tissues with the same gauge)
AMP412HR3020 PDO Prime, ½ circle HR30 conical point needle, USP 2/0, violet, 75 cm (greater penetration arc, same point configuration)

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team of Cahnos.

Additional information

Brand

PREMISUT

Manufacturer reference

P412DR2020

Material

Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer

Thread structure

Fluted monofilament (not braided)

Gauge

USP 2/0 (metric 3)

Thread diameter

0.30 – 0.349 mm (indicative according to Pharmacopoeia)

Thread colour

Violet grooved

Needle shape

3/8 circle (approx. 135°)

Needle body

Cylindrical

Needle tip

Taperpoint conical

Needle size

DR20 – 20 mm, 1 needle per suture

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Regulatory standard

USP / European Pharmacopoeia (EP)

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 sterile units

Medida de aguja

DR 20

Usp

2/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture · Needle ⅜ Circle Cylindrical Body Conical Point Taperpoint DR20 (20 mm) · USP Gauge 2/0 (Metric 3) · Violet Grooved Thread 75 cm · Ref. P412DR2020 · Box 12 units”

Your email address will not be published. Required fields are marked *