Description
1. Product Presentation
The Prime line absorbable polydioxanone (PDO/PDS) monofilament suture is the reference technical choice when tissue requires prolonged support during healing with fully predictable resorption and minimal tissue reaction. This presentation combines a 90 cm violet thread in USP 5/0 gauge with double needle of ⅜ circle, cylindrical body and conical point (taperpoint) of 17 mm (2xDR17), an atraumatic configuration designed for soft, delicate and well-perfused tissues. Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with full traceability in each pack.
2. Technical Explanation
Polydioxanone is an absorbable synthetic polyester —a polymer of poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures a highly reproducible absorption kinetics between individuals. With complete absorption in 180–210 days, it offers one of the longest support windows among absorbable sutures. Being a non-fluted monofilament, the thread has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared to braided threads. Its firm feel and excellent knotting capacity make it suitable for ligatures and planes under sustained tension.
The ⅜ circle needle with cylindrical body and conical point (taperpoint) passes through tissue by separating the fibres rather than cutting them, which minimises bleeding and tissue damage. The double needle configuration (2xDR17) allows continuous suture techniques and approximation from both ends without re-threading, optimising performance in the operating theatre. The USP 5/0 gauge (metric 1) offers the optimal balance between strength and delicacy for skin, subcutaneous tissue, mucosa and fine structures. It is supplied sterile by ethylene oxide, single-use and non-resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference AMP413DR1750-2
| Parameter | Specification |
|---|---|
| SKU Cahnos | AMP413DR1750-2 |
| Factory reference | P413DR1750-2 |
| Material | Polydioxanone (PDO/PDS), poly(p-dioxanone), synthetic non-fluted monofilament |
| Thread structure | Absorbable monofilament, non-braided |
| Quality | Prime (premium range) |
| USP / metric gauge | USP 5/0 (metric EP 1.0) |
| Thread length | 90 cm |
| Thread colour | Violet (high visibility) |
| Needle shape | ⅜ circle |
| Needle body | Cylindrical |
| Tip type | Conical / Taperpoint |
| Needle size | DR 17 (17 mm), double needle (2x) |
| Swaged | Double needle, one needle at each end of the thread |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units; minimum order 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial strength |
| 4 weeks | 60–70% of the initial strength |
| 8 weeks | 45% of initial strength |
| Complete absorption | 180–210 days by hydrolysis |
This prolonged force retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, which is why it is recommended for closures of planes under sustained traction and in paediatric cardiovascular surgery where tissue growth is expected.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (PDO material, USP 5/0 gauge, 90 cm violet thread, 17 mm conical point needle, double needle), the following homologous references have been compared in the official catalogue of manufacturers and authorised distributors, comparable at category level and not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone monofilament) violet, double needle RB-1 of 17 mm conical point, USP 5/0, 90 cm | Z9108H | Comparable by category (not interchangeable 1:1) | Matches material, USP 5/0 gauge, violet colour, 90 cm length, 17 mm conical point and double needle configuration. The curvature differs: RB-1 needle of ½ circle versus ⅜ circle of this reference. Code confirmed in official Ethicon catalogue and authorised distributors. |
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone monofilament) violet, BB needle of 17 mm in ⅜ circle, conical point, USP 5/0, 70 cm | W9073H | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, ⅜ circle curvature and 17 mm taperpoint needle. Differences: single needle configuration (1xBB) versus double needle and thread length of 70 cm versus 90 cm. Code verified in authorised Ethicon distributors. |
| B. Braun / Aesculap | MonoPlus® (violet polydioxanone monofilament), HR17 needle of 17 mm conical point, USP 5/0, 70 cm | C0024013 | Comparable by category (not interchangeable 1:1) | Matches material, USP 5/0 gauge, violet colour and 17 mm conical point. Differences: ½ circle needle (HR17) versus ⅜, single needle configuration and length of 70 cm versus 90 cm. Code confirmed in official B. Braun catalogue. |
There is no equivalence table validated by the manufacturer that declares this reference as interchangeable 1:1 with other brands; consult the technical department before using in tenders. As homologous families in the sector, the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), MonoPlus® from B. Braun/Aesculap, Surgicryl PDO from SMI and Maxon from Medtronic/Covidien are cited. In all cases, the USP gauge, curvature, body, point, needle size, configuration and thread length must be verified code by code in the official technical data sheet and IFU before any substitution. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue, mucosa and delicate planes —as in this reference—, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and tension-bearing planes. Needle geometry is also decisive: the conical point (DR/HR) is indicated for delicate, well-perfused tissues (vessels, parenchyma), while the trocar point (DRT/HRT) is reserved for firmer tissues and the reverse cutting triangular point (DS) for fibrous tissues.
Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with conical point and double needle includes variants of interest: AMP418DR1350-2 (DR13 needle, 13 mm, USP 5/0, 70 cm) for microsurgery and very restricted operative fields, AMP418DR1730-2 (DR17 needle, 17 mm, USP 3/0, 70 cm) for firmer tissue planes, AMP418DR1740-2 (DR17 needle, USP 4/0, 70 cm) as an intermediate gauge step, and AMP413HRP1750-2 (double ½ circle needle, Ultra Plus trocar point, 17 mm, USP 5/0, 90 cm) when greater penetration firmness is required. If you prefer a ½ circle needle with a conical point, the reference AMP412HR1710 (HR17, USP 0, 75 cm) is available. Always verify the USP gauge, size and geometry of the needle against your surgical protocol before substituting one reference for another.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference AMP413DR1750-2 and the batch number for traceability in the operating theatre. Store in a cool, dry place, below 30 °C and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.