Description
1. Commercial Introduction
The absorbable monofilament polydioxanone PDO Prime VisiBlack suture is the reference solution for professionals and purchasing centres that need a long-term absorbable thread with predictable behaviour and excellent handling in delicate tissues. Its VisiBlack needle facilitates visibility of the puncture point and the suture path even in surgical fields with poor lighting or high vascularisation, while the 70 cm violet thread offers optimal contrast on the tissue.
It is presented sterile and ready for individual use in a box of 12 units with batch traceability, in a B2B format aimed at hospital replenishment, operating theatres and public tenders. Article reference P418DR9,370VB (SKU Cahnos AMP418DR9,370VB).
2. Technical Explanation
Polydioxanone (PDO, poly(p-dioxanone)) is a synthetic absorbable polyester that is presented in a monofilament structure: lacking interstices and wicking effect, it offers a very smooth passage through the tissue, lower bacterial adherence and minimal tissue reaction. Its absorption occurs by hydrolysis, independent of the patient’s enzymatic activity, over a predictable period of 180 to 210 days, which provides prolonged wound support far superior to that of medium-term absorbables (PGA or PGLA).
The tensile strength retention curve is 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks, maintaining sufficient resistance during the critical healing phase. The DR 9.3 VisiBlack Prime needle, ⅜ circle, cylindrical body and taperpoint conical tip, penetrates by separating the fibres without cutting them (atraumatic passage), reducing trauma and bleeding at the passage point; it is especially valued in vascular, ocular and friable tissues. The USP 7/0 (metric EP 0.5) gauge offers an optimal balance between fineness and strength. The product is sterile by ethylene oxide (EO) and single-use: do not re-sterilise.
3. Technical Specifications
3.1. Technical data sheet of the reference
| Parameter | Specification |
| Brand / Range | Prime VisiBlack (Cahnos) |
| Article reference | P418DR9,370VB |
| SKU Cahnos | AMP418DR9,370VB |
| Material | Synthetic polydioxanone (PDO), poly(p-dioxanone), monofilament |
| Thread structure | Monofilament, smooth non-grooved surface |
| Suture type | Synthetic absorbable (long-term) |
| USP gauge / size | USP 7/0 (metric EP 0.5); indicative diameter 0.050 – 0.069 mm |
| Thread length | 70 cm (1 thread per unit) |
| Thread colour | Violet |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Cylindrical body, conical tip (taperpoint) |
| Needle size | 9.3 mm (DR 9.3 VisiBlack Prime profile), single needle |
| Swaged | 1 needle per suture |
| Absorption | By hydrolysis, 180 – 210 days; minimal tissue reaction |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular surgery and ophthalmology |
| Commercial presentation | Box of 12 units (individual sterile sachets); batch traceability; minimum order 10 boxes |
| Regulatory standard | Conforms to USP Pharmacopoeia / European Pharmacopoeia (EP) for sterile absorbable sutures |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | Approximately 75 % of initial strength |
| 4 weeks | 60 – 70 % of initial strength |
| 8 weeks | Approximately 45 % of initial strength |
| Complete absorption | 180 – 210 days (hydrolysis) |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (indicative)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 8/0 | 0.4 | 0.040 – 0.049 mm |
| 7/0 (this product) | 0.5 | 0.050 – 0.069 mm |
| 6/0 | 0.7 | 0.070 – 0.099 mm |
4. Equivalences and Cross-References
The reference P418DR9,370VB corresponds to the nomenclature of the PDO Prime VisiBlack range (DR 9.3 profile, single taperpoint conical tip needle of 9.3 mm, USP 7/0 gauge, 70 cm violet thread, needle in VisiBlack finish). Cahnos markets the product with its own SKU while keeping the article reference unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | PDS® II – violet polydioxanone monofilament, USP 7/0, 70 cm, double-armed with CC needles (taper-cut micropoint) | Z1711E (consistently verified in Ethicon EPC catalogue and authorised distribution; not currently registered in GUDID) | Comparable by category (not interchangeable 1:1) | They match in material (poly(p-dioxanone)), gauge 7/0, violet colour, length 70 cm and conical point family; they differ in arming (double vs single needle) and needle type (CC taper-cut micropoint vs taperpoint DR 9.3 VisiBlack) |
| Ethicon (Johnson & Johnson MedTech) | PDS® II – violet polydioxanone monofilament, USP 7/0, 70 cm, double needle 2×BV-1 with conical point ⅜ circle | Z1701E (verified in authorised distribution and Ethicon catalogues) | Comparable by category (not interchangeable 1:1) | Same material, gauge 7/0, violet colour and length of 70 cm; double arming 2×BV-1 (conical point of approx. 9 mm) vs single VisiBlack DR 9.3 needle; the dark finish of the needle also differs |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As a homologous family on the market with the same polymer (long-term polydioxanone monofilament), the PDS® II / PDS® Plus range from Ethicon and the Monoplus® range from B. Braun (PDO monofilament) can be cited, although for Monoplus® it has not been possible to verify in active public sources a specific 7/0 reference with this exact needle geometry (DR 9.3 taperpoint, single needle, 70 cm). This configuration is only fully safely interchangeable within the PDO Prime VisiBlack range itself. Consult the technical department of Cahnos to validate any equivalence before use in tenders.
5. Selection tips and variants of interest
Tissue to suture: USP 7/0 (EP 0.5) gauge is a fine thread with high manageability, indicated for approximation of soft and delicate tissues, ligatures, general surgery, paediatric cardiovascular surgery and ophthalmology. The conical point needle (taperpoint) separates fibres without cutting them: it is the natural choice for lax, well-irrigated tissues and vascular structures; for planes requiring greater penetration (skin, fascia), consider triangular point or trocar profiles from the same family.
Needle size: the DR 9.3 mm profile offers a medium-high length within the conical family, ideal for medium working surgical fields. The VisiBlack needle improves contrast of the puncture point on dark or highly vascularised tissues.
Variants of interest in the Cahnos catalogue:
| Reference | Variant of interest |
| AMP418DR9,370-2 (P418DR9,370-2) | PDO Prime USP 7/0, double needle DR 9.3, violet, 70 cm (continuous suture or double anchoring) |
| AMP418DR9,360-2 (P418DR9,360-2) | PDO Prime USP 6/0, double needle DR 9.3, violet, 70 cm (larger gauge) |
| AMP111DR9,360 (P111DR9,360) | PGA Prime USP 6/0, DR 9.3 taperpoint needle, violet, 45 cm (medium absorption 60-90 days) |
| AMP114DR6,580 (P114DR6,580) | PGA Prime USP 8/0, DR 6.5 taperpoint needle, violet, 30 cm (finer) |
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P418DR9,370VB and the batch number for traceability in the operating theatre and in case of complaint. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews