Description
1. Product Presentation
The polydioxanone (PDO/PDS) absorbable monofilament suture from the Prime range is the choice of the professional who needs a prolonged absorption suture with predictable mechanical behaviour. This reference combines a violet 75 cm suture in USP 5/0 gauge with a ⅜ circle needle with triangular reverse cutting body and point, 12 mm (DS12), a precision geometry designed for fine, low-elasticity tissues. It is the B2B supply solution for operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology departments and hospital purchasing centres seeking consistent quality with CE marking. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.
2. Technical explanation
Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics. As a monofilament, the suture has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilament sutures. Its firm feel and excellent knot-holding capacity make it ideal for ligatures and sutures of tissue planes subjected to sustained tension during the critical healing phase.
The ⅜ circle needle (approximate curvature of 135°) with reverse cutting triangular point concentrates the cutting edge on the outer aspect of the curve, preventing tearing of superficial tissues. The USP 5/0 gauge (metric 1) and the short 12 mm needle make it an excellent configuration for reduced surgical fields and delicate tissues. The fluted violet colour improves visibility over the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AMP412DS1250
| Parameter | Specification |
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Fluted monofilament (not braided) |
| Quality / range | Prime |
| Gauge / size | USP 5/0 (metric 1) |
| Thread colour | High-visibility violet |
| Thread length | 75 cm |
| Swaged | 1 needle per pack (single strand) |
| Needle shape | 3/8 circle (approx. 135°) |
| Needle body and point | Triangular, reverse cutting point |
| Needle size | DS12 Prime – 12 mm |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Reference (SKU) | AMP412DS1250 (412DS series from the PDO Prime range) |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
| Complete absorption | 180-210 days by hydrolysis, with minimal tissue reaction |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, and its use is therefore recommended in closures of fascia, aponeurosis, paediatric cardiovascular structures and planes subjected to sustained traction.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that officially cross-references this product (⅜ circle reverse cutting needle DS12, 12 mm, USP 5/0 gauge, violet 75 cm thread, monofilament) with the commercial ranges of other brands; consult the technical department before use in tenders.
As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating; the homologous needle geometry of ⅜ circle triangular reverse cutting corresponds to its PC needle series with fine gauges 5/0-6/0 for paediatric tissue), the MonoPlus® line from B. Braun/Aesculap and the Surgicryl® PDO line from SMI. All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, since small variations in needle radius or point profile prevent a 1:1 equivalence.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (5/0 to 6/0), as in this reference, for skin, subcutaneous tissue and paediatric cardiovascular structures; 3/0 and 2/0 for general soft tissue; and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the reverse cutting triangular point (DS) is indicated for fibrous, low-elasticity tissues, while the conical point (HR/DR) is reserved for delicate, well-perfused tissues.
Within the Cahnos catalogue, the PDO/PDS family includes variants of interest:
| Reference | Variant of interest |
| AMP418DS1940FN | PDO Prime Fine, DS19 needle, 19 mm, USP 4/0, violet, 70 cm (fine tissues, reduced needle body) |
| AMP412DS2430 | PDO Prime, DS24 needle, 24 mm, USP 3/0, violet, 75 cm (same point family, larger gauge and needle) |
| AMP418DR1350-2 | PDO Prime, double ⅜ circle needle, conical point, 13 mm, USP 5/0, violet, 70 cm (same gauge, atraumatic conical point) |
| AMP414GR1950 | PDO Prime, straight needle, conical point, 19 mm, USP 5/0, violet, 30 cm (straight needle for superficial approximations) |
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.