Description
1. Commercial Introduction
The absorbable monofilament polydioxanone (PDO/PDS) Prime suture from the Premisut range is the reference choice for hospitals, clinics and purchasing centres looking for a long-lasting absorbable synthetic thread with a very competitive price-performance ratio. This presentation mounts a ⅜ circle needle with a 24 mm reverse cutting triangular point (DS 24 profile), USP 3/0 gauge and two 75 cm violet threads with double needle: a versatile configuration for general surgery and specialties that require prolonged wound support.
It is supplied sterile, ready for individual use, in a box of 12 sachets with batch traceability, in a B2B format oriented to hospital replenishment, tenders and supply agreements. SKU Cahnos: AMP412DS2430.2.
2. Technical Explanation
Polydioxanone (PDO, a poly(p-dioxanone) polymer) is a synthetic absorbable polyester that degrades by hydrolysis on contact with organic fluids, with minimal inflammatory response and a fully predictable absorption rate. Its monofilament structure facilitates passage through tissue with less friction, eliminates interstitial spaces and reduces the risk of bacterial colonisation compared with braided threads, while maintaining excellent tensile strength and optimal knot tying.
The DS 24 needle (⅜ circle, reverse cutting triangular point or reverse cutting) concentrates the cutting edge on the outer face of the curvature: it penetrates firm, non-distensible tissues such as skin, mucosa or aponeurosis with a clean cut without enlarging the puncture bed, reducing tissue tearing. The double needle format with two 75 cm threads allows continuous sutures or anchors to be performed without rethreading, a relevant operational advantage in large surgical fields. The violet colour guarantees immediate contrast on the surgical field.
3. Technical Specifications
3.1. Technical data sheet for reference AMP412DS2430.2
| Parameter | Specification |
| Thread material | Polydioxanone (PDO/PDS), poly(p-dioxanone) polymer, synthetic absorbable monofilament |
| Suture type | Long-term synthetic absorbable |
| Gauge / size | USP 3/0 (metric EP 2) |
| Thread length | 2 × 75 cm (two threads per unit) |
| Thread colour | Violet (high visibility) |
| Needle shape | ⅜ circle (3/8 circular) |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | 24 mm (DS 24 profile) |
| Swaged | Double needle (2 needles · 2 threads) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 180-210 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| SKU Cahnos | AMP412DS2430.2 |
3.2. Tensile strength retention profile
| Period | Tensile retention |
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Monofilament polydioxanone is the most widespread family of prolonged-absorption absorbable sutures on the international market, with homologous lines such as PDS II® / PDS Plus® from Ethicon (Johnson & Johnson MedTech) and MonoPlus® from B. Braun (Aesculap), both of violet monofilament polydioxanone. Reference AMP412DS2430.2 (412DS series of the PDO Prime range) corresponds to the manufacturer’s official nomenclature within its system: DS needle of ⅜ circle, 24 mm reverse cutting triangular point, USP 3/0, 75 cm violet thread, double needle.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | MonoPlus® – uncoated monofilament polydioxanone, violet, double needle | C0024103 (verified in official B. Braun catalogue: USP 3/0, double needle, DSMP24 needle of ⅜ circle reverse cutting with precision point, 24 mm, 45 cm thread) | Comparable by category (not interchangeable 1:1) | They match in material (polydioxanone), gauge 3/0, violet colour, ⅜ radius, 24 mm reverse cutting needle and double-armed configuration. They differ in thread length (45 cm vs 2×75 cm) and point geometry (DSMP with precision point vs standard DS); confirm IFU before substituting. |
There is no manufacturer-validated equivalence table that cross-references this exact configuration (DS 24 mm reverse cutting needle, USP 3/0, double needle, 2×75 cm) with other brands as interchangeable 1:1. The homologous lines PDS II® / PDS Plus® from Ethicon or Maxon from Medtronic require case-by-case verification of needle size and geometry, thread length, colour and regulatory classification before any substitution. Consult with the technical department of Cahnos before use in tenders. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
Tissue to suture: USP 3/0 gauge is very versatile: suitable for subcutaneous tissue, superficial muscle planes, skin approximation, aponeurosis and soft tissues with moderate tension. The reverse cutting point is especially recommended for fibrous and non-distensible structures; if an even more atraumatic entry is preferred in lax or vascular tissue, consider the conical point profiles of the same PDO range.
Variants within the Prime range:
| Variant / Reference | Description |
| AMP412DS1930 | PDO Prime DS 19 mm · USP 3/0 · violet · 75 cm (same family, shorter needle, single thread) |
| AMP412DR1730 | PDO Prime DR 17 mm · USP 3/0 · violet · 75 cm (cylindrical conical point, atraumatic entry) |
| AMP411XDS1350 | PDO Prime XDS 13 mm · USP 5/0 · violet · 45 cm (extra-long precision reverse cutting with square body, cosmetic profile) |
Material alternatives: if the protocol requires shorter wound support (60-90 days), the range offers multifilament polyglycolic acid (PGA) sutures; if a non-absorbable profile is required, polypropylene, nylon and Prime silk are available. Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure and keep the reference together with the batch number for traceability in the operating theatre. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.