We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone Suture PDO/PDS | Needle ⅜ Circle Triangular Body Reverse Cutting Point DS30 (30 mm) | USP Size 0 (Metric 3.5) | Violet Fluted Thread 75 cm | Ref. 412DS3010 | Box of 12 units

Original price was: 44,90 €.Current price is: 32,35 €.

Absorbable monofilament polydioxanone suture (PDO/PDS) with a ⅜ circle needle, triangular body and reverse cutting point of 30 mm (DS30). USP size 0 (metric 3.5) and violet fluted thread of 75 cm, with predictable absorption by hydrolysis in 180-210 days and retention of 75% of tensile strength at 2 weeks. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures, fascia, general surgery, paediatric cardiovascular tissues and ophthalmology. Ref. 412DS3010 · SKU AM412DS3010, presentation in a box of 12 sterile units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM412DS3010

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm violet grooved thread in USP 0 gauge with a ⅜ circle needle, triangular body and 30 mm reverse cutting point (DS30), a geometry designed to pass through fibrous tissue with a clean and controlled passage. Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures a highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillarity, which reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared to multifilaments. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.

The ⅜ circle needle with reverse cutting triangular point presents the cutting edge on the outer face of the curve, which prevents tearing of superficial tissue and makes it especially suitable for skin, subcutaneous tissue, aponeuroses and other fibrous planes. With a length of 30 mm (DS30) and USP 0 gauge (metric 3.5), this configuration offers high tensile strength for planes under tension. The grooved violet colour improves thread visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Grooved monofilament
Quality Normal (standard)
Gauge / size USP 0 (metric 3.5)
Thread length 75 cm
Thread colour Violet (high visibility)
Needle shape ⅜ circle
Needle body and point Triangular, reverse cutting point, grooved
Needle size DS30 – 30 mm
Swaged 1 needle per pack (single strand)
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units (individual pack)
Factory reference / SKU 412DS3010 / AM412DS3010

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %
Complete absorption 180-210 days by hydrolysis

This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeuroses and structures subjected to sustained tension.

3.3. Size equivalence

USP size Metric size Approximate diameter
0 3.5 0.35 – 0.399 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this technical data sheet (⅜ circle reverse cutting triangular needle of 30 mm, USP 0 gauge, 75 cm violet thread), the following commercial reference from another manufacturer has been cross-checked in primary sources:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® (polydioxanone) violet monofilament, USP 0 gauge Z970H Comparable by category (not interchangeable 1:1) Same PDO monofilament material and same USP 0 gauge, confirmed in the GUDID/FDA regulatory database and authorised distributors. Differences: CP-2 needle of ½ circle with reverse cutting point of 26 mm versus the ⅜ circle DS30 needle of 30 mm of this reference, and thread length of 70 cm versus 75 cm (single thread).

There is no equivalence table validated by the manufacturer that officially cross-references this reference with the commercial series of other brands; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked in their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension, as in this reference. Needle geometry is also decisive: the reverse cutting triangular point (DS) is indicated for fibrous and non-elastic tissues (skin, aponeuroses), while the conical point (HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma).

Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes variants of interest: AMP412DS3010 (Prime quality, same DS30 configuration, USP 0, violet, 75 cm) as the higher range; AMP412DS3010.2 (double thread 2 × 75 cm, same needle) for prolonged continuous sutures; AMP412DS2620.2 (DS26 needle of 26 mm, USP 2/0, 2 × 75 cm) for a slightly lower gauge while maintaining the double thread; AMP412DS3630 (DS36 needle of 36 mm, USP 3/0, 75 cm) for longer reach accesses; and AMP418HS2620 (½ circle HS26 mm needle, USP 2/0, 70 cm) if the protocol prefers half-circle curvature. If loose thread is required for ligatures, reference AM41-2.7020 (USP 2/0, without needle, 2 × 70 cm) covers that format. Always verify the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer

Thread structure

Grooved monofilament

Quality

Normal (standard)

Gauge

USP 0 (metric 3.5)

Thread diameter

0.35 – 0.399 mm (indicative according to Pharmacopoeia)

Needle shape

3/8 circle (approx. 135°)

Tip type

Triangular reverse cutting (reverse cutting)

Needle size

DS 30 (30 mm)

Swaged

1 needle per pack (single strand)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 units

Manufacturer reference

412DS3010

Medida de aguja

DS 30

Usp

0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone Suture PDO/PDS | Needle ⅜ Circle Triangular Body Reverse Cutting Point DS30 (30 mm) | USP Size 0 (Metric 3.5) | Violet Fluted Thread 75 cm | Ref. 412DS3010 | Box of 12 units”

Your email address will not be published. Required fields are marked *