Prime absorbable monofilament polydioxanone (PDO/PDS) suture in USP gauge 4/0, with a ⅜ circle needle with triangular body and reverse cutting point of 19 mm (DS19), violet fluted thread of 75 cm. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 and 45% at 8. Sterilised by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, subcutaneous tissue, paediatric cardiovascular planes and ophthalmology. Presentation in box of 12 units, minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412DS1940

Description

1. Product Presentation

The Prime absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when the tissue requires prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm violet grooved thread in USP 4/0 gauge with a ⅜ circle needle, triangular body and 19 mm reverse cutting point (DS19), designed to penetrate firm tissues with excellent penetration power and minimal trauma. Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery units, dermatology, ophthalmology and hospital purchasing centres seeking consistent quality with CE marking.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. As a monofilament, the thread has no wicking effect or capillarity, which reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting ability make it ideal for ligatures and closure of planes subjected to sustained tension during the critical healing phase.

The ⅜ circle needle with triangular body and reverse cutting point is designed for compact and fibrous tissues: the cutting edge is oriented away from the wound, preventing tearing of surrounding tissue and being particularly suitable for skin, subcutaneous tissue, aponeuroses and slow-healing structures. The USP 4/0 gauge (metric 1.5) offers an optimal balance between strength and delicacy. The violet grooved colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and non-reesterilisable.

3. Technical Specifications

3.1. General characteristics

Specification Detail
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Grooved monofilament
Gauge USP 4/0 (metric 1.5)
Thread length 75 cm
Thread colour Violet (high visibility)
Needle shape ⅜ circle
Needle body and point Triangular, reverse cutting point
Needle size DS19 – 19 mm
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, skin and subcutaneous tissue, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units · Minimum order 30 boxes
Factory reference / SKU 412DS1940 / AMP412DS1940

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended for skin closures, subcutaneous tissue, aponeuroses and structures subjected to sustained traction.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). Against the verified configuration of this data sheet (⅜ circle triangular reverse cutting needle of 19 mm, USP 4/0 gauge, 75 cm violet thread), the following commercial reference from another manufacturer has been compared:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Johnson & Johnson MedTech (Ethicon) PDS II® (polydioxanone) violet monofilament, PS-2 needle Z513G Comparable by category (not interchangeable 1:1) Same PDO monofilament material, same USP 4/0 gauge, same ⅜ circle PS-2 needle of 19 mm with reverse cutting point and violet colour. Difference: thread length of 45 cm (18″) versus 75 cm for this reference. Confirmed in the Ethicon catalogue and authorised distributors.

There is no equivalence table validated by the manufacturer that officially cross-references this product with commercial series from other brands; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl PDO line from SMI, the Maxon line from Medtronic/Covidien and the PDSYNTH range of Italian manufacture available in our catalogue on request. All must be checked against their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and superficial planes —as is the case with this reference—, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the reverse cutting triangular point (DS) is the ideal option for compact and fibrous tissues (skin, aponeuroses) due to its tear-free penetration, while the conical point (DR/HR) is reserved for delicate and well-perfused tissues and the trocar point (DRT) for more resistant tissues.

Within the Cahnos catalogue, the PDO/PDS family includes variants of interest: AM412HR2630 (½ circle cylindrical HR26 needle of 26 mm, USP 3/0, 75 cm) for soft tissues; AMP418HRP2240-2 (double ½ circle needle with Ultra Plus conical point, USP 4/0, 70 cm) for continuous sutures; AMP413DR1750-2 (double ⅜ circle needle with conical point of 17 mm, USP 5/0, 90 cm) for finer tissues; and AMP418DRT1350 (⅜ circle trocar point of 13 mm, USP 5/0, 70 cm) for firm tissues. Always verify the USP gauge, size and geometry of the needle against your surgical protocol before substituting one reference for another.

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS)

Thread structure

Grooved monofilament

USP size

4/0 (metric 1.5)

Needle type

Triangular, reverse cutting point

Needle size

DS19 – 19 mm

Strength retention

75% (2 weeks), 60-70% (4 weeks), 45% (8 weeks)

Sterilisation

Ethylene oxide

Presentation

Box of 12 units

Minimum order

30 boxes

Use

Tissue approximation, ligatures, general surgery, skin and subcutaneous tissue, paediatric cardiovascular, ophthalmology

Reference

412DS1940

Medida de aguja

DS 19

Usp

4/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)