Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture, reference AM412DS1930, is the technical reference choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines USP 3/0 (metric 2) gauge with a ⅜ circle needle, body and triangular reverse cutting point (reverse cutting) of 19 mm (DS19) and a 75 cm violet grooved thread.
It is the B2B supply solution for operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology services and hospital purchasing centres seeking quality consistency with CE marking. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals, completing between 180 and 210 days. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared to multifilament threads. Its firm feel and excellent knotting capacity make it ideal for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.
The ⅜ circle needle (approximate curvature of 135°) with a reverse cutting triangular point has the cutting edge on the outer face of the curve, which prevents tearing of superficial tissue and makes it especially suitable for skin, subcutaneous tissue, aponeurosis, fascia and other fibrous planes. With a length of 19 mm (DS19) and USP 3/0 gauge, this configuration offers an optimal balance between strength and delicacy for general soft tissue. The grooved violet colour improves thread visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Fluted monofilament (not braided) |
| Gauge / size | USP 3/0 (metric 2) |
| Approximate diameter | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
| Thread colour | High-visibility violet, fluted |
| Thread length | 75 cm |
| Swaged | 1 needle per pack (single strand) |
| Needle shape | 3/8 circle (approx. 135°) |
| Needle body and point | Triangular, reverse cutting point |
| Needle size | DS19 – 19 mm |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, fascia closure, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units · Minimum order 30 boxes |
| Factory reference / SKU | 412DS1930 / AM412DS1930 |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis, with minimal tissue reaction |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained traction.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (⅜ circular reverse cutting triangular needle of 19 mm, USP 3/0 gauge, 75 cm violet thread), commercial references from other manufacturers have been compared in official catalogues and authorised distributors; all coincide in material (PDO monofilament) and reverse cutting needle family, but differ in thread length or colour, so they are classified as comparable by category and not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun / Aesculap | MonoPlus® (polydioxanone) uncoated monofilament, violet | C0024519 | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same violet colour, same USP 3/0 gauge and same DS19 ⅜ circle reverse cutting needle (19 mm). Differences: thread length (70 cm vs 75 cm) and coating (uncoated). Confirmed in official B. Braun catalogue (search C0024519) and authorised distributors. |
| Johnson & Johnson MedTech (Ethicon) | PDS II® (polydioxanone) monofilament, precision reverse cutting point | Z497G | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 3/0 gauge and same PS-2 needle of 19 mm ⅜ circle reverse cutting. Differences: colourless thread (not violet) and length of 45 cm (18″) vs 75 cm. Confirmed in the product data sheet of authorised distributor Ethicon. |
| Johnson & Johnson MedTech (Ethicon) | PDS II® (polydioxanone) violet monofilament, reverse cutting | Z968H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same violet colour, same USP 3/0 gauge and same ⅜ circle reverse cutting needle family. Differences: needle size (CP-2 of 26 mm vs DS19 of 19 mm) and thread length (70 cm vs 75 cm). Confirmed in catalogues of authorised Ethicon distributors. |
There is no equivalence table validated by the manufacturer that officially cross-references this reference with the commercial series of other brands; consult the technical department of Cahnos before use in tenders. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap and the Surgicryl® PDO line from SMI. All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, as well as the attachment. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the reverse cutting triangular point (DS/HS) is indicated for fibrous and inelastic tissues (skin, aponeurosis, fascia), while the conical point (HR/SH) is reserved for delicate and well-perfused tissues (vessels, parenchyma).
Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes variants of interest: AMP412DS1930 (Prime quality, same DS19 configuration, USP 3/0, violet, 75 cm), AM412DS2430 (DS24 needle of 24 mm, USP 3/0, violet, 75 cm), AM412DS2410 (DS24 needle of 24 mm, USP 0, violet, 75 cm), AMP412DS2420 (Prime, DS24 needle, USP 2/0, violet, 75 cm) and AMP418DS2440 (Prime, DS24 needle, USP 4/0, violet, 70 cm). Always verify the USP gauge, the size and geometry of the needle against your surgical protocol before substituting one reference for another. All references are supplied in boxes of 12 units.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews