Description
1. Product Presentation
The Prime range absorbable monofilament polydioxanone (PDO/PDS) suture is the technical reference when tissue requires prolonged support during healing and fully predictable reabsorption. This presentation combines USP 2/0 gauge with a ⅜ circle needle, body and reverse cutting triangular point of 24 mm (DS24) and a double violet fluted thread format of 2×75 cm, designed for continuous sutures, ligatures of tension-bearing planes and high-consumption surgical programmes.
Available in a box of 12 sterile units, it is a reliable and cost-effective B2B supply solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity with CE marking. Factory ref. P412DS2420.2 · SKU AMP412DS2420.2.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures a highly reproducible absorption kinetics between individuals, completing between 180 and 210 days. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes under sustained tension during the critical healing phase.
The ⅜ circle needle (approximate curvature of 135°) with reverse cutting triangular point presents the cutting edge on the outer face of the curve, which prevents tearing of superficial tissue and makes it especially suitable for skin, subcutaneous tissue, aponeurosis, fascia and other fibrous planes. With a length of 24 mm (DS24) and USP 2/0 gauge (metric 3), this configuration offers an excellent balance between strength and delicacy. The double thread format (2×75 cm) allows prolonged continuous sutures or multiple stitches without re-threading the needle, optimising performance in the operating theatre. The fluted violet colour improves visibility over the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Quality / range | Prime (PREMISUT) |
| Gauge / size | USP 2/0 (metric 3) |
| Approximate diameter | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
| Thread colour | High-visibility violet, fluted |
| Thread length | 2 threads of 75 cm (2×75 cm) |
| Swaged | 1 needle per suture (2 needles and 2 sutures per pack) |
| Needle shape | ⅜ circle |
| Needle body and point | Triangular, reverse cutting point, grooved |
| Needle size | DS24 Prime – 24 mm |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, fascia closure, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Factory reference / SKU | P412DS2420.2 / AMP412DS2420.2 |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis, with minimal tissue reaction |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis and structures under sustained traction.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (⅜ circle reverse cutting triangular needle of 24 mm, USP 2/0 gauge, violet thread and double armed 2×75 cm), the following commercial reference from another manufacturer in the official catalogue has been compared:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun / Aesculap | MonoPlus® (polydioxanone) uncoated monofilament, violet | G0024990 (USP 2/0 / EP 3, 70 cm, violet, DS24 needle ⅜ circle reverse cutting body 24 mm) | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 2/0 gauge (EP 3), same violet colour and same DS24 ⅜ circle reverse cutting needle family (24 mm). They differ: thread length (70 cm vs 75 cm) and arming (single thread vs double thread 2×75 cm). Confirmed in the official catalogue of B. Braun. |
As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved; the homologous needle geometry of ⅜ circle reverse cutting triangular corresponds to its PC needle series), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, as well as the double arming (2×75 cm) of this presentation.
There is no equivalence table validated by the manufacturer that officially cross-references this reference with the commercial series of other brands; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and tension-bearing planes. Needle geometry is also decisive: the reverse cutting triangular point (DS/HS) is indicated for fibrous and non-elastic tissues (skin, aponeurosis, fascia), while the conical point (HR/SH) is reserved for delicate and well-perfused tissues (vessels, parenchyma). The double thread format 2×75 cm maximises performance in long continuous sutures and reduces the number of opened packages per procedure.
Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes variants of interest: the single-thread version of this same configuration (DS24, USP 2/0, violet, 75 cm), the AMP412DS2620.2 (DS26 needle of 26 mm, USP 2/0, double thread 2×75 cm) for prolonged continuous sutures, the AMP412DS2410.2 (DS24 needle of 24 mm, USP 0, double thread 2×75 cm) for higher-tension planes and the AMP412DS2430 (DS24 needle of 24 mm, USP 3/0, 75 cm) for more delicate tissues. Always verify the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.