We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone PDO/PDS Suture Prime – 3/8 Circle Reverse Cutting Triangular Point Needle 36 mm (DS36) – USP 3/0 Gauge – Violet Thread 75 cm – Box of 12 units · Ref. AMP412DS3630

Original price was: 64,90 €.Current price is: 43,50 €.

Absorbable monofilament polydioxanone (PDO/PDS) suture Prime with a ⅜ circle reverse cutting triangular point needle of 36 mm (DS36), USP 3/0 gauge and 75 cm violet fluted thread. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75 % at 2 weeks, 60–70 % at 4 weeks and 45 % at 8 weeks. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and Ophthalmology. Presentation in box of 12 units for operating theatre stock. Ref. AMP412DS3630.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412DS3630

Description

1. Product Presentation

The Prime absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical option when the tissue requires prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm violet fluted thread in USP 3/0 gauge with a ⅜ circle needle, triangular body and 36 mm reverse cutting point (DS36), a geometry designed to pass through fibrous, low-elasticity tissue with a clean, controlled passage. Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillarity, which reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it ideal for ligatures and sutures of layers subjected to sustained tension during the critical healing phase.

The ⅜ circle needle with reverse cutting triangular point has the cutting edge on the outer face of the curve, which prevents tearing of superficial tissue and makes it particularly suitable for skin, subcutaneous tissue, aponeuroses and other fibrous layers. With a 36 mm length (DS36) and USP 3/0 gauge (metric 2), this configuration offers an optimal balance of strength, penetration and handling for general soft tissue. The fluted violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Grooved monofilament
Gauge USP 3/0 (metric equivalent 2)
Thread length 75 cm
Thread colour Violet (high visibility)
Needle shape ⅜ circle
Needle body and point Triangular, reverse cutting point
Needle size DS36 – 36 mm
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units
Factory reference / SKU P412DS3630 / AMP412DS3630

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended for closures of fascia, aponeuroses and structures under sustained tension. Individual sterile packaging, ready for use.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market’s reference lines for long-lasting absorbable sutures (PDS type). Based on the verified configuration of this technical data sheet (⅜ circle reverse cutting triangular needle of 36 mm, USP 3/0 gauge, 75 cm violet thread), the following commercial references from another manufacturer have been compared:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Johnson & Johnson MedTech (Ethicon) PDS II (polydioxanone) monofilament, FS-1 reverse cutting needle Z442H Comparable by category (not interchangeable 1:1) Same PDO monofilament material, same USP 3/0 gauge and same reverse cutting point family; the FS-1 needle is ⅜ circle but 19 mm compared with 36 mm (DS36) for this reference, and the thread is 70 cm compared with 75 cm. Confirmed in an authorised distributor’s catalogue listing.
Johnson & Johnson MedTech (Ethicon) PDS II (polydioxanone) violet monofilament, CP-2 reverse cutting needle Z761D Comparable by category (not interchangeable 1:1) Same material, USP 3/0 gauge, violet colour and reverse cutting point; significant difference: CP-2 needle of 24 mm versus DS36 of 36 mm and thread of 45 cm versus 75 cm for this reference. Confirmed in an authorised distributor’s catalogue listing.

There is no equivalence table validated by the manufacturer that officially cross-references this product with the commercial ranges of other brands; consult the technical department before use in tenders. As homologous market families to be verified code by code before substitution: the PDS II and PDS Plus lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked against their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue layer: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and layers under tension. Needle geometry is also decisive: the reverse cutting triangular point (DS) is indicated for fibrous, low-elasticity tissues (skin, aponeuroses), while the conical point (HR) is reserved for delicate, well-perfused tissues (vessels, parenchyma) and the trocar point (DRT) for firm tissues of greater resistance.

Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes variants of interest: AMP412DS1930 (DS19 needle of 19 mm, USP 3/0, 75 cm) for more restricted access with the same gauge; AMP412DS2420 (DS24 needle of 24 mm, USP 2/0, 75 cm) for a slightly thicker profile; AM411DS1950 (DS19 needle, USP 5/0, 45 cm) for very fine tissues. If the protocol requires a conical point, reference AM412HR2630 (½ circle, HR26, USP 3/0, 75 cm) covers well-perfused tissues with the same absorption kinetics. Always verify the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS) absorbable monofilament

USP size

3/0 (metric 2)

Thread colour

Violet grooved

Needle type

Reverse cutting triangular

Needle size

DS36 – 36 mm

Sterilisation

Ethylene oxide, single-use

Presentation

Box of 12 sterile units

Manufacturer reference

P412DS3630

Use

Tissue approximation, ligatures, general surgery, paediatric cardiovascular, ophthalmology

Medida de aguja

DS 36

Usp

3/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Suture Prime – 3/8 Circle Reverse Cutting Triangular Point Needle 36 mm (DS36) – USP 3/0 Gauge – Violet Thread 75 cm – Box of 12 units · Ref. AMP412DS3630”

Your email address will not be published. Required fields are marked *