We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture – 3/8 Circle Reverse Cutting Triangular Needle DS12 (12 mm) – USP 6/0 – Violet Thread 45 cm – Box of 12 units · Ref. AMP411DS1260

Original price was: 76,09 €.Current price is: 50,80 €.

Absorbable monofilament polydioxanone (PDO/PDS) suture in Prime quality, with a ⅜ circle body needle and reverse cutting triangular point (reverse cutting) of 12 mm (DS12), USP 6/0 gauge (metric 0.7) and violet non-ribbed thread, 45 cm, with high visibility in the field. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 and 45% at 8, providing prolonged support ideal for slow-healing tissues. Sterilised by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in a box of 12 units. Ref. AMP411DS1260.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP411DS1260

Description

1. Product Presentation

The Prime range polydioxanone (PDO/PDS) monofilament absorbable suture is the choice of the professional who needs a prolonged absorption thread with predictable mechanical behaviour and minimal tissue reaction. This reference combines a non-grooved violet thread of 45 cm in USP 6/0 gauge with a ⅜ circle needle, with triangular reverse cutting body and point of 12 mm (DS12 Prime profile): a precision geometry designed for fine, low-elasticity tissues and reduced surgical fields. Available in a box of 12 units, it is the B2B supply solution for operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology and hospital purchasing centres seeking consistent quality with CE marking and gauges conforming to USP/European Pharmacopoeia.

2. Technical explanation

Polydioxanone is an absorbable synthetic polyester —a polymer of poly(p-dioxanone)— that degrades by hydrolysis: a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics (180–210 days). Being a non-grooved monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical phase of healing.

The ⅜ circle needle (approximate curvature of 135°) with triangular reverse cutting point (reverse cutting), body and point, concentrates the cutting edge on the outer face of the curve: it prevents tearing of superficial tissues and achieves controlled penetration in firm, non-distensible tissues. The USP 6/0 gauge (metric 0.7) and the short 12 mm needle make it an excellent configuration for reduced surgical fields and delicate tissues. The violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and non-resterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference AMP411DS1260

Parameter Specification
Thread material Polydioxanone (PDO/PDS), synthetic polymer of poly(p-dioxanone)
Thread structure Non-grooved monofilament, uncoated (Prime finish)
Suture type Long-term synthetic absorbable
Gauge / size USP 6/0 (metric EP 0.7)
Approximate diameter 0.070 – 0.099 mm (indicative according to USP/Pharmacopoeia)
Thread length 45 cm (1 strand per unit)
Thread colour High-visibility violet, non-grooved
Needle shape 3/8 circle (approx. 135°)
Needle body and point Triangular, reverse cutting (reverse cutting), body and point
Needle size DS12 Prime – 12 mm
Swaged 1 needle per pack (single strand)
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (EO) — sterile, single-use, non-resterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units (individual pouches)
Reference / SKU AMP411DS1260
Regulatory standard Conforms to USP / European Pharmacopoeia (EP) gauges

3.2. Tensile strength retention profile

Time after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeurosis, paediatric cardiovascular structures and planes subjected to sustained traction.

3.3. Size equivalence

USP size Metric size Approximate diameter
6/0 0.7 0.070 – 0.099 mm (indicative according to USP/Pharmacopoeia)

4. Equivalences and Cross-References

Polydioxanone monofilament is the material basis of the market reference lines for long-term absorbable sutures (PDS-type family). For the verified configuration of this data sheet (⅜ circle triangular reverse cutting needle of 12 mm, USP 6/0 gauge, violet thread of 45 cm), no reference from another manufacturer has been found in public sources that matches field by field (material, gauge, ⅜ curvature, reverse cutting point family, DS12 size and 45 cm length), so no exact reference equivalence is declared. The homologous reference verified in official sources is as follows:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® violet – polydioxanone monofilament, P-1 Precision Point needle of ⅜ circle with reverse cutting, USP 6/0, 45 cm Z487G (verified in Ethicon catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match in material (polydioxanone), monofilament structure, gauge 6/0, length 45 cm, violet colour and ⅜ radius with precision reverse cutting. The needle size differs (11 mm P-1 vs 12 mm DS12, within ±1 mm tolerance) and the precision point profile; verify IFU before substituting.

No equivalence table validated by the manufacturer exists for this specific configuration (DS12 needle, 12 mm, with reverse cutting triangular point in PDO, USP 6/0 gauge, violet thread, 45 cm); consult the technical department of Cahnos before using in tenders or direct substitution. Other homologous polydioxanone families available on the market —PDS II® / PDS Plus® from Ethicon, MonoPlus® from B. Braun/Aesculap or the Surgicryl PDO line from SMI— must be reviewed property by property (exact material, USP/EP gauge, needle size and geometry, curvature, thread length, colour, attachment and CE/MDR classification) before any substitution. The brands cited belong to their respective manufacturers and are mentioned only as a comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (5/0 to 6/0), like this reference, for skin, subcutaneous tissue and paediatric cardiovascular structures; 3/0 and 2/0 for general soft tissue; and USP 0 and above for fascia and tension-bearing planes. Needle geometry is also decisive: the reverse cutting triangular point (DS series) is indicated for fibrous and low-elasticity tissues with controlled penetration, while the tapered point (DR/HR) is reserved for delicate, well-perfused tissues. Within the Cahnos catalogue, the PDO/PDS family includes variants of interest:

Reference (SKU) Variant of interest
AMP411DS1260 PDO Prime, DS12 mm needle, USP 6/0, violet, 45 cm (current product)
AMP411DS1250 PDO Prime, DS12 mm needle, USP 5/0, violet, 45 cm (same needle, thicker gauge)
AMP412DS1250 PDO Prime, DS12 mm needle, USP 5/0, violet, 75 cm (longer thread length)
AMP411DS1950 PDO Prime, DS19 mm needle, USP 5/0, violet, 45 cm (same family, longer needle)
AMP411XDS1350 PDO Prime, XDS 13 mm extra-long precision needle with square body, USP 5/0, violet, 45 cm (cosmetic profile)
AMP411XDS1150 PDO Prime, XDS 11 mm precision needle, USP 5/0, violet, 45 cm (precision for very small surfaces)

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic polymer of poly(p-dioxanone)

Thread structure

Non-grooved monofilament, uncoated (Prime finish)

Suture type

Long-term synthetic absorbable

USP size

6/0 (metric EP 0.7)

Thread diameter

0.070 – 0.099 mm (indicative according to USP/Pharmacopoeia)

Thread length

45 cm (1 strand per unit)

Thread colour

High-visibility violet

Needle shape

3/8 circle (approx. 135°)

Needle tip

Triangular reverse cutting (reverse cutting), body and point

Needle size

DS12 Prime – 12 mm

Swaged

1 needle per pack (single strand)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 sterile units (individual pouches)

Quality

Prime (range PREMISUT)

Regulatory standard

Conforms to USP / European Pharmacopoeia (EP) gauges

Medida de aguja

DS 12

Usp

6/0

Color

Violet

Medida de hilo

45 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture – 3/8 Circle Reverse Cutting Triangular Needle DS12 (12 mm) – USP 6/0 – Violet Thread 45 cm – Box of 12 units · Ref. AMP411DS1260”

Your email address will not be published. Required fields are marked *