Description
1. Product Presentation
The Prime line’s absorbable monofilament polydioxanone (PDO) suture is the reference technical choice when tissue requires prolonged support during healing, with fully predictable resorption and minimal tissue reaction. This presentation combines a 75 cm violet grooved thread in USP 4/0 gauge with a ⅜ circle needle, triangular body and reverse cutting point of 16 mm (DS16), a geometry designed to penetrate fibrous tissue with a clean and controlled passage.
Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking.
2. Technical explanation of the product and procedure
Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillarity, which reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it ideal for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.
The ⅜ circle needle with reverse cutting triangular point has the cutting edge on the outer face of the curve, which prevents tearing of superficial tissue and makes it particularly suitable for skin, subcutaneous tissue and inelastic fibrous planes. With a length of 16 mm (DS16) and USP 4/0 gauge, this configuration offers an excellent balance between strength and delicacy. The grooved violet colour improves thread visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Range | Cahnos (Prime quality) |
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Gauge / size | USP 4/0 (metric 1.5) |
| Approximate diameter | 0.15 – 0.199 mm (indicative according to Pharmacopoeia) |
| Thread colour | Violet (high visibility) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Needle body and point | Triangular, reverse cutting point, grooved |
| Needle size | DS16 – 16 mm |
| Swaged | 1 needle per pack (single strand) |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, skin, subcutaneous tissue, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Factory reference / SKU | P412DS1640 / AMP412DS1640 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This extended force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of skin, subcutaneous tissue, aponeuroses and structures under sustained tension.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (⅜ circular reverse cutting triangular needle of 16 mm, USP 4/0 gauge, 75 cm violet thread), a commercial reference from another manufacturer, verified in authorised commercial sources, is cited below; it is offered as a functional category comparison, not as a 1:1 interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone) monofilament | Z441H (USP 4/0, 27″ ~70 cm, colourless, FS-1 ⅜ circle reverse cutting needle, approx. 19 mm) | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material and same USP 4/0 gauge with ⅜ circle reverse cutting needle geometry. Differences: needle length (FS-1 ~19 mm vs DS16 16 mm), colour (undyed vs violet), thread length (~70 cm vs 75 cm) and presentation (box of 12/36 units depending on market). |
There is no manufacturer-validated equivalence table that officially cross-references this product with other brands’ commercial series; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap, the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked against their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue —as is the case with this reference—, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the reverse cutting triangular point (DS) is indicated for fibrous and inelastic tissues (skin, aponeuroses), while the conical point (HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma).
Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes variants of interest: AMP412DS1940 (DS19 needle of 19 mm, USP 4/0, 75 cm, Prime quality) if the protocol requires a slightly larger needle; AMP412DR1940 (⅜ circle cylindrical needle with conical point of 19 mm, USP 4/0) for delicate tissues; and for higher or lower gauges, AMP412DS2620 (USP 2/0, DS26) or AMP412DS1250 (USP 5/0, DS12). Always verify the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews