We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | USP 3/0 | Needle Half Circle Cylindrical Body Trocar Point (Tapercut) HRT17 17 mm | Violet 70 cm | Box of 12 units | Ref. AMP418HRT1730

51,86 €

Absorbable monofilament polydioxanone (PDO/PDS) suture, Prime quality with a half-circle needle, cylindrical body and trocar point (tapercut) of 17 mm (HRT17), size USP 3/0 and a 70 cm violet thread. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75 % at 2 weeks, 60-70 % at 4 weeks and 45 % at 8 weeks. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Manufacturer’s reference P418HRT1730, presentation in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HRT1730

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range, reference AMP418HRT1730, is the professional solution for the surgeon who needs a thread with prolonged absorption, excellent handling and maximum knot security in the approximation of soft tissues and ligatures. It incorporates a ½ circle needle with cylindrical body and trocar point (tapercut) of 17 mm (HRT17), violet thread of 70 cm and USP 3/0 gauge.

It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for the B2B supply of operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology departments and purchasing centres. Commercial presentation in a box of 12 units.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer presented in a monofilament structure, which gives it a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence. Its degradation occurs by hydrolysis, i.e., by scission of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days. This prolonged absorption profile maintains the necessary tensile strength during the critical phases of healing, being especially useful in tissues that require prolonged support.

The ½ circle needle with cylindrical body and trocar point (tapercut geometry) combines a rounded body, which passes through tissue atraumatically, with a controlled cutting point that allows penetration of tissues of a certain density, such as fascia and moderately fibrous tissue, with moderate effort and without tearing. The code HRT17 corresponds to a 17 mm long needle, mounted in a single-needle configuration. It is the reference configuration in general surgery, tissue approximation and vascular ligatures. The product is sterilised by ethylene oxide, is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference AMP418HRT1730

Parameter Specification
Material Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)
Thread structure Synthetic monofilament
Quality Prime (Premium range)
Gauge USP 3/0
Thread colour Violet
Needle shape 1/2 circle
Needle body Cylindrical
Tip type Trocar / Tapercut
Needle size HRT 17 (17 mm), one needle
Thread length 70 cm
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (EO), single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units
Factory reference P418HRT1730
SKU Cahnos AMP418HRT1730

3.2. Tensile strength retention profile

Period Tensile strength retention
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %

Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most well-established synthetic absorbable suture material with prolonged absorption on the market. The USP 3/0 configuration, 70 cm violet thread and ½ circle needle has a counterpart in international reference lines; however, the commercial needles of those lines usually mount a conical point (taper point) and needle sizes different from the HRT17 of 17 mm:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson) PDS II – monofilament polydioxanone, USP 3/0, violet, 70 cm, SH needle (26 mm, ½ circle, conical point) Z316H Comparable by category (not interchangeable 1:1) Same material, gauge and thread length; the point geometry differs (conical taper point versus trocar tapercut) and the needle size (26 mm versus 17 mm). Presentation 36 units.
Ethicon (Johnson & Johnson) PDS II – monofilament polydioxanone, USP 3/0, violet, 70 cm, CT-2 needle (26 mm, ½ circle, conical point) Z332H Comparable by category (not interchangeable 1:1) Same material, gauge and thread length; CT-2 conical point needle of 26 mm instead of HRT17 trocar point of 17 mm. Presentation 36 units.

There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference with trocar point (HRT17) in USP 3/0 gauge; consult the technical department before use in tenders. As category equivalents (same indication and same polymer, without code verified in primary source), the violet monofilament PDO/PDS suture families from other laboratories are cited, such as the MonoPlus line from B. Braun; in all cases, the USP gauge, needle size and configuration (1 needle) must be verified in the manufacturer’s technical data sheet before substituting. Within the Cahnos catalogue, the same complete configuration (PDO, HRT17 needle, USP 3/0, violet, 70 cm) in Normal quality corresponds to reference AM418HRT1730.

5. Selection tips and variants of interest

USP 3/0 gauge is ideal for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia, muscle and ligatures of medium-fine calibre vessels. The 17 mm trocar point needle is recommended in tissues of medium density or slightly fibrous, where the passage must be clean and without tearing; if a fully atraumatic point is preferred, consider the conical point versions of the same family (HRP).

Reference Description
AM418HRT1730 PDO Normal quality, HRT17 needle of 17 mm, USP 3/0, violet, 70 cm (economical alternative)
AMP418HRT1720 PDO Prime, HRT17 needle of 17 mm, USP 2/0, violet, 70 cm (thicker gauge)
AMP418HRT1740 PDO Prime, HRT17 needle of 17 mm, USP 4/0, violet, 70 cm (greater precision)
AMP418HRT1750 PDO Prime, HRT17 needle of 17 mm, USP 5/0, violet, 70 cm (fine gauge, ophthalmology)
AMP418HRT2630 PDO Prime, HRT26 needle of 26 mm, USP 3/0, violet, 70 cm (longer needle, fascia and dense tissues)
AMP418HRP1720 PDO Prime, HRP17 needle of 17 mm Ultra Plus conical point, USP 2/0, violet, 70 cm (atraumatic point)

All references are supplied in a box of 12 units. Keep the original packaging in a dry, cool place, respect the expiry date and handle the strand with gloves to avoid altering its mechanical properties. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)

Thread structure

Synthetic monofilament

Quality

Prime (Premium range)

Gauge

USP 3/0

Needle body

Cylindrical

Needle size

HRT 17 (17 mm), one needle

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Manufacturer reference

P418HRT1730

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Medida de aguja

HRT 17

Usp

3/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | USP 3/0 | Needle Half Circle Cylindrical Body Trocar Point (Tapercut) HRT17 17 mm | Violet 70 cm | Box of 12 units | Ref. AMP418HRT1730”

Your email address will not be published. Required fields are marked *