We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone Suture PDO/PDS · Needle 1/2 Circle Cylindrical Body Trocar Point HRT17 (17 mm) · USP Gauge 2/0 · Violet Thread 70 cm · Box of 12 units

38,56 €

Absorbable monofilament polydioxanone (PDO/PDS) suture with a 1/2 circle needle, cylindrical body and trocar point of 17 mm (HRT17), USP gauge 2/0 and 70 cm violet grooved thread. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Ref. 418HRT1720 · SKU AM418HRT1720, presentation in a box of 12 units with B2B conditions for hospitals and purchasing centres.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM418HRT1720

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when prolonged tissue support is required with fully predictable resorption and minimal tissue reaction. This presentation combines a 70 cm fluted violet thread in USP 2/0 gauge with a ½ circle needle, cylindrical body and 17 mm trocar point (HRT17), designed to penetrate firm or moderately resistant tissues without delaminating delicate structures.

Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking. Factory reference 418HRT1720; SKU AM418HRT1720.

2. Technical explanation of the product and procedure

Polydioxanone is an absorbable synthetic polyester (poly(p-dioxanone) polymer) that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillary action, which reduces bacterial adherence and facilitates sliding through tissue; its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes under sustained tension.

The ½ circle needle (half-circumference curvature) with cylindrical body and trocar point combines the penetration of a cutting point with the atraumatic passage characteristic of a cylindrical needle: it is ideal for tissues of firm or moderately resistant consistency (aponeurosis, fascia, thick-walled vessels) and for paediatric cardiovascular surgery, where precision without tearing is required. The USP 2/0 gauge (metric 3) is versatile: suitable for subcutaneous tissue, superficial muscular planes and approximation of soft tissues. The fluted violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, is single-use and cannot be resterilised.

3. Technical Specifications

3.1. General characteristics

Characteristic Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Grooved monofilament
Gauge / size USP 2/0 (metric 3)
Thread colour Violet
Needle shape ½ circle (half circumference)
Needle body Cylindrical
Tip type Trocar point (cylindrical body with cutting tip)
Needle size HRT 17 mm
Thread length 70 cm
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units
Factory reference / SKU 418HRT1720 / AM418HRT1720

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %
Complete absorption 180-210 days by hydrolysis

This strength retention profile is maintained during the critical healing phase of slow-healing tissues, which recommends its use in closures of fascia, aponeurosis and structures under sustained traction. It is supplied sterile, ready for use, in individual packaging.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). Against the verified configuration of this technical data sheet (½ circle needle with 17 mm trocar point, USP 2/0 gauge, 70 cm violet thread), the following commercial references from other manufacturers have been cross-checked in primary sources:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone), CT-2 needle Z333H Comparable by category (not interchangeable 1:1) Same PDO monofilament material, same USP 2/0 gauge, same 70 cm violet thread and same ½ circle curvature; difference: 26 mm conical point (taper point) versus the 17 mm trocar point of this reference. Confirmed at authorised distributors.
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone), CT needle W9151T Comparable by category (not interchangeable 1:1) Same PDO monofilament material, USP 2/0 gauge and 70 cm violet thread; cutting needle geometry different from the 17 mm trocar point (HRT17) of this reference. Confirmed at authorised distributors.
B. Braun / Aesculap MonoPlus (polydioxanone) uncoated, violet C0024086 Comparable by category (not interchangeable 1:1) Same PDO monofilament material, USP 2/0 gauge (EP 3), 70 cm violet thread; HR26S conical point needle versus 17 mm trocar point. Confirmed in official B. Braun catalogue.

As homologous market families to be verified code by code before substitution: Ethicon’s PDS Plus line (same PDO base with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus line from B. Braun in trocar point configurations available at authorised distributors, SMI’s Surgicryl PDO line and Medtronic/Covidien’s Maxon line. All must be checked in their official technical data sheet (gauge, length, colour and needle geometry). There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. Needle shape is also decisive: the trocar point (cylindrical body with cutting point) is designed for firm or moderately resistant tissues where penetration with minimal trauma is desired, while the pure conical point (HR/SH) is reserved for very delicate tissues such as friable vessels.

Within the Cahnos catalogue, the PDO/PDS family of ½ circle with trocar point (HRT) includes variants of interest: the same HRT17 needle in USP 4/0 gauge with 70 cm violet thread and Prime quality (AMP418HRT1740); the HR22 taperpoint conical point version in USP 2/0 (AMP418HR2220) for standard soft tissue; the HS26 reverse cutting triangular version in USP 2/0 (AMP418HS2620) for fibrous tissues; and HR26 conical point presentations in 3/0 gauge (AM412HR2630) for delicate tissues. For laparoscopic surgery or procedures requiring two active ends, double-needle configurations are available in the PDO range.

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic absorbable monofilament

Structure

Grooved monofilament

Gauge

USP 2/0 (metric 3)

Needle body

Cylindrical

Tip type

Trocar point (cylindrical body with cutting tip)

Sterilisation

Ethylene oxide, single-use

Presentation

Box of 12 units

Indications

General surgery, paediatric cardiovascular tissues, ophthalmology, ligatures

Manufacturer reference

418HRT1720

Medida de aguja

HRT 17

Usp

2/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone Suture PDO/PDS · Needle 1/2 Circle Cylindrical Body Trocar Point HRT17 (17 mm) · USP Gauge 2/0 · Violet Thread 70 cm · Box of 12 units”

Your email address will not be published. Required fields are marked *