Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when prolonged tissue support is required with fully predictable resorption and minimal tissue reaction. This presentation combines a 70 cm fluted violet thread in USP 2/0 gauge with a ½ circle needle, cylindrical body and 17 mm trocar point (HRT17), designed to penetrate firm or moderately resistant tissues without delaminating delicate structures.
Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking. Factory reference 418HRT1720; SKU AM418HRT1720.
2. Technical explanation of the product and procedure
Polydioxanone is an absorbable synthetic polyester (poly(p-dioxanone) polymer) that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillary action, which reduces bacterial adherence and facilitates sliding through tissue; its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes under sustained tension.
The ½ circle needle (half-circumference curvature) with cylindrical body and trocar point combines the penetration of a cutting point with the atraumatic passage characteristic of a cylindrical needle: it is ideal for tissues of firm or moderately resistant consistency (aponeurosis, fascia, thick-walled vessels) and for paediatric cardiovascular surgery, where precision without tearing is required. The USP 2/0 gauge (metric 3) is versatile: suitable for subcutaneous tissue, superficial muscular planes and approximation of soft tissues. The fluted violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, is single-use and cannot be resterilised.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Gauge / size | USP 2/0 (metric 3) |
| Thread colour | Violet |
| Needle shape | ½ circle (half circumference) |
| Needle body | Cylindrical |
| Tip type | Trocar point (cylindrical body with cutting tip) |
| Needle size | HRT 17 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 units |
| Factory reference / SKU | 418HRT1720 / AM418HRT1720 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
| Complete absorption | 180-210 days by hydrolysis |
This strength retention profile is maintained during the critical healing phase of slow-healing tissues, which recommends its use in closures of fascia, aponeurosis and structures under sustained traction. It is supplied sterile, ready for use, in individual packaging.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). Against the verified configuration of this technical data sheet (½ circle needle with 17 mm trocar point, USP 2/0 gauge, 70 cm violet thread), the following commercial references from other manufacturers have been cross-checked in primary sources:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone), CT-2 needle | Z333H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 2/0 gauge, same 70 cm violet thread and same ½ circle curvature; difference: 26 mm conical point (taper point) versus the 17 mm trocar point of this reference. Confirmed at authorised distributors. |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone), CT needle | W9151T | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, USP 2/0 gauge and 70 cm violet thread; cutting needle geometry different from the 17 mm trocar point (HRT17) of this reference. Confirmed at authorised distributors. |
| B. Braun / Aesculap | MonoPlus (polydioxanone) uncoated, violet | C0024086 | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, USP 2/0 gauge (EP 3), 70 cm violet thread; HR26S conical point needle versus 17 mm trocar point. Confirmed in official B. Braun catalogue. |
As homologous market families to be verified code by code before substitution: Ethicon’s PDS Plus line (same PDO base with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus line from B. Braun in trocar point configurations available at authorised distributors, SMI’s Surgicryl PDO line and Medtronic/Covidien’s Maxon line. All must be checked in their official technical data sheet (gauge, length, colour and needle geometry). There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. Needle shape is also decisive: the trocar point (cylindrical body with cutting point) is designed for firm or moderately resistant tissues where penetration with minimal trauma is desired, while the pure conical point (HR/SH) is reserved for very delicate tissues such as friable vessels.
Within the Cahnos catalogue, the PDO/PDS family of ½ circle with trocar point (HRT) includes variants of interest: the same HRT17 needle in USP 4/0 gauge with 70 cm violet thread and Prime quality (AMP418HRT1740); the HR22 taperpoint conical point version in USP 2/0 (AMP418HR2220) for standard soft tissue; the HS26 reverse cutting triangular version in USP 2/0 (AMP418HS2620) for fibrous tissues; and HR26 conical point presentations in 3/0 gauge (AM412HR2630) for delicate tissues. For laparoscopic surgery or procedures requiring two active ends, double-needle configurations are available in the PDO range.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews