We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone Suture PDO/PDS · Needle ½ Circle Cylindrical Body Trocar Point Tapercut 40 mm (HRT 40) · USP Size 0 · Thread 150 cm with Loop · Violet Grooved · Ref. 415HRT40L10 – Box of 12 units

53,34 €

Absorbable monofilament suture of Polydioxanone (PDO/PDS) with a ½ circle needle, cylindrical body and trocar point (Tapercut), 40 mm (HRT 40), USP size 0 (metric 3.5) and violet grooved thread of 150 cm in loop format. Predictable absorption by hydrolysis between 180 and 210 days, with tension retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, with minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular surgery, ophthalmology and fascia closure. Presentation in box of 12 units. Ref. 415HRT40L10 (SKU AM415HRT40L10).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM415HRT40L10

Description

The absorbable monofilament Polydioxanone (PDO/PDS) suture presented by Cahnos, reference 415HRT40L10 (SKU AM415HRT40L10), is the reference choice for hospitals, private clinics, ophthalmologists and purchasing centres seeking a long-lasting synthetic absorbable thread with a very competitive quality-price ratio.

This presentation combines a ½ circle needle with a cylindrical body and trocar point (Tapercut) of 40 mm, USP gauge 0 and a violet grooved thread of 150 cm mounted in a loop. It is supplied sterile and ready to use, and is especially indicated for the approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissues, ophthalmology and fascia closure, where prolonged wound support is required (tissues that take more than 6 weeks to regain their strength).

Technical explanation

Polydioxanone is a synthetic absorbable polymer (poly(p-dioxanone)) that degrades by hydrolysis, i.e., by contact with organic fluids, with minimal inflammatory response. Its monofilament structure facilitates passage through tissue with less friction and eliminates interstitial spaces, reducing the risk of bacterial colonisation compared with braided threads.

The ½ circle needle, cylindrical body and trocar point (Tapercut) combines the progressive entry of a conical point with improved penetration capacity for firm tissues such as fascia, peritoneum or sclera, minimising tissue damage. The loop format allows the first stitch to be placed and the continuous suture to be anchored without rethreading, a clinically relevant advantage in reduced surgical fields and laparoscopic surgery. The grooved violet colouration ensures optimal visibility of the thread throughout the procedure.

Technical specifications

3.1. Technical data sheet for reference AM415HRT40L10

Characteristic Specification
Reference (SKU) 415HRT40L10 (SKU AM415HRT40L10)
Range / Quality Premisut, normal quality
Material Polydioxanone (PDO/PDS), synthetic monofilament
Gauge USP 0 (metric 3.5)
Colour Fluted violet
Thread length 150 cm with loop
Needle shape ½ circle
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size 40 mm (HRT 40)
Absorption mechanism Hydrolysis
Absorption period 180-210 days
Sterilisation Ethylene oxide (EO), single-use
Tissue reaction Minimal
Presentation Box of 12 units

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %

Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues, ophthalmology and fascia closure. Price per box of 12 units.

Equivalences and cross-references

Monofilament polydioxanone is a family of long-lasting absorbable sutures that is clinically compared with the main lines on the international market. Below are listed the references verified against the official catalogue of the cited manufacturer:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS Plus (polydioxanone with triclosan) – Needle V-37 Tapercut ½ circle 40 mm, violet, loop 150 cm PDP1932T / PDP1935T Comparable by category (not interchangeable 1:1) Same material (PDO), same Tapercut needle of 40 mm, same loop format of 150 cm and violet colour; incorporates antimicrobial coating of triclosan (PDS Plus). Verify USP gauge of each code before substituting.
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone) – Needle V-37 Tapercut ½ circle 40 mm, violet W9366T / W9370T Comparable by category (not interchangeable 1:1) Same needle (V-37, 40 mm, Tapercut) and same material; differs in thread length and format (90 cm without loop versus 150 cm with loop).
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone) – Needle V-40 Tapercut ½ circle 48 mm, violet, loop Z1930G Comparable by category (not interchangeable 1:1) Same material, same family and loop format; differ in needle size (48 mm versus 40 mm) and thread length (180 cm versus 150 cm).

There is no equivalence table validated by the manufacturer for cross-brand substitution in the exact configuration of HRT 40 mm trocar needle with 150 cm loop; consult the technical department before use in tenders. For any formal substitution, the material, gauge (USP 0), needle size and geometry (½ circle, trocar point, 40 mm radius), thread length and format (150 cm, loop), colour and regulatory classification of each reference must be verified one by one, since small variations in needle radius or thread length prevent a 1:1 equivalence. Within the same clinical category, the reference prolonged-absorption monofilament polydioxanone lines in the sector also include MonoPlus from B. Braun, comparable at category level and not interchangeable 1:1.

Selection tips and variants of interest

USP gauge 0 (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, fascia closure, abdominal wall and approximation of soft tissues with moderate tension. The trocar point (Tapercut) is especially recommended for fibrous and dense structures; if an even more atraumatic entry into soft tissue is preferred, consider the conical point variant of the same gauge.

The 150 cm loop format is ideal for continuous suturing or anchoring without rethreading. For a larger needle radius, the version with HRT 48 mm needle (ref. AM415HRT48L10) is available; Prime presentations with Ultra Plus conical point of 40 mm (AMP415HRP40L01), 48 mm (AMP415HRP48L10) and 65 mm (AMP415HRP65L10) are also available, as well as other gauges and lengths within the PDO family from Cahnos. As it is a sterile single-use product, always check the integrity of the packaging before each procedure and comply with the traceability required by the centre.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament

Gauge

USP 0 (metric 3.5)

Needle size

40 mm (HRT 40)

Needle shape

½ circle, cylindrical body

Thread length

150 cm, loop format

Colour

Fluted violet

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Reference

415HRT40L10 (SKU AM415HRT40L10)

Medida de aguja

HRT 40

Usp

0

Color

Violet

Medida de hilo

150 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone Suture PDO/PDS · Needle ½ Circle Cylindrical Body Trocar Point Tapercut 40 mm (HRT 40) · USP Size 0 · Thread 150 cm with Loop · Violet Grooved · Ref. 415HRT40L10 – Box of 12 units”

Your email address will not be published. Required fields are marked *