We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Suture Absorbable Monofilament Polydioxanone (PDO/PDS) Prime · Needle ½ Circle Cylindrical Body Conical Point Taperpoint HR17 17 mm · USP 4/0 (Metric 1.5) · Violet Thread 70 cm · Box of 12 units (Ref. P412HR1740 · SKU AMP412HR1740)

46,34 €

Suture synthetic absorbable polydioxanone (PDO/PDS) monofilament in Prime quality, with a ½ circle needle with cylindrical body and conical point (taperpoint) of 17 mm (HR17), USP 4/0 gauge (metric 1.5) and violet thread of 70 cm. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 and 45% at 8. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Factory ref. P412HR1740, in a box of 12 units (SKU AMP412HR1740).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412HR1740

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Premisut range in Prime quality, reference P412HR1740, is the benchmark choice for surgery departments, ophthalmology, paediatric cardiovascular surgery units and procurement centres seeking an absorbable thread with prolonged support, predictable behaviour and high knot-tying security. It incorporates a ½ circle cylindrical body needle with taperpoint conical tip of 17 mm, USP 4/0 gauge and violet thread 70 cm long. Supplied sterile, in individual envelopes, with professional presentation as a box of 12 units and batch traceability, under B2B conditions ideal for operating theatres, ophthalmology clinics and tenders. Cahnos markets this reference keeping the factory code P412HR1740 unchanged (SKU AMP412HR1740).

2. Technical Explanation

Polydioxanone is a synthetic absorbable polyester, a poly(p-dioxanone) polymer, presented in a monofilament structure. This configuration gives the thread a smooth surface that reduces friction when passing through tissue, minimises the sawing effect, hinders bacterial adherence and provides excellent handling and knot security. Its degradation occurs by hydrolysis, i.e. by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days and independent of the patient’s enzymatic activity, with minimal tissue reaction.

This prolonged absorption profile maintains the necessary tensile strength during the critical phases of healing: 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. The ½ circle needle with cylindrical body and taperpoint conical tip of 17 mm (HR17) penetrates the tissue atraumatically, separating the fibres without cutting – the standard configuration in ophthalmic surgery, delicate tissue approximation and fine vascular ligatures. The violet colour ensures optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and must not be resterilised.

3. Technical Specifications

3.1. Technical data sheet for reference P412HR1740

Parameter Specification
Factory reference P412HR1740
Reference Cahnos (SKU) AMP412HR1740
Brand / Quality Premisut – Prime
Material Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)
Thread structure Synthetic monofilament
USP / metric gauge 4/0 (metric 1.5)
Thread colour Violet
Thread length 70 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (taperpoint), atraumatic
Needle size 17 mm (HR 17)
Configuration Single needle (1 × HR17)
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units

3.2. Tensile strength retention and absorption profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
4 weeks 60-70 % of the initial tensile strength
8 weeks 45 % of the initial tensile strength
Total absorption 180-210 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimum knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most widely proven synthetic absorbable suture material for prolonged absorption on the market (type ‘PDS’). The USP 4/0, violet thread 70 cm and ½ circle needle with conical tip 17 mm configuration matches international reference lines; however, the Prime finish of the needle and the box of 12 presentation are specific to this reference, so the cross-references indicated are comparable at category level and not interchangeable point by point.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) PDS® II – monofilament polydioxanone, USP 4/0, violet, 70 cm, RB-1 needle of ½ circle, taper point, 17 mm Z304H Comparable by category (not interchangeable 1:1) Verified in the official Ethicon catalogue and authorised distributors: polymer, gauge, colour, length, shape and needle size (17 mm) match; needle finish differs (RB-1 vs. HR17 Prime) and presentation (box of 36 units vs. 12 units)
Ethicon (J&J MedTech) PDS® Plus Antibacterial – polydioxanone with antibacterial coating (triclosan), USP 4/0, violet, 70 cm, RB-1 needle 17 mm, ½ circle, conical tip PDP304H Comparable by category (not interchangeable 1:1) Same gauge, colour, length and 17 mm needle configuration; fundamental difference: triclosan antibacterial coating and different needle finish. Check IFU
B. Braun MonoPlus® – monofilament polydioxanone, violet, USP 4/0, 70 cm, ½ circle needle 17 mm (trocar tip variant HRT17) C0024284 Comparable by category (not interchangeable 1:1) Verified in the official B. Braun catalogue: polymer, gauge, colour, length and needle length (17 mm) match; tip differs (trocar tapercut vs. conical taperpoint), with a different penetration profile. For a pure conical tip, the MonoPlus line requires checking the specific HR17 code

There is no equivalence chart validated by the manufacturer for this reference versus third-party brands; consult the technical department before using in a tender. Before substituting, check on the candidate’s data sheet: USP gauge, thread length, needle configuration (1 needle / double needle), tip type (conical, trocar/tapercut or reverse cutting), curvature (½ or ⅜), needle size, coating and regulatory classification (CE/MDR) of the actual product.

5. Selection tips and variants of interest

USP 4/0 gauge (metric 1.5) is ideal for thin and low-to-medium tension tissues: skin, subcutaneous tissue, mucosa, microsurgery, fine vascular ligatures and precision approximations, with special application in ophthalmology and paediatric cardiovascular surgery, where prolonged support and the least possible trauma are sought. The ½ circle conical tip needle of 17 mm is the most atraumatic option for these tissues.

Reference (SKU) Description
AMP412HR1740 PDO Prime, HR17 needle conical point, USP 4/0, violet, 70 cm (this product)
AMP412HR1750 PDO Prime, HR17 needle conical point, USP 5/0, violet, 75 cm (fine gauge, ophthalmology and microsurgery)
AMP418HR1740-2 PDO Prime, double needle 2×HR17 taper point, USP 4/0, violet, 70 cm (double-armed for laparoscopy)
AMP418HRT1740 PDO Prime, HRT17 needle trocar point (tapercut), USP 4/0, violet, 70 cm (cutting point for denser tissues)
AMP418HRP1740 PDO Prime, HRP17 needle conical point Ultra Plus, USP 4/0, violet, 70 cm (precision point finish)

If a shorter absorption profile is required, consider the multifilament families in the catalogue (PGLA polyglactin 910 ref. P1L12HR1740 or PGA ref. AMP112HR1740), always with the same HR17 needle. As this is a sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference P412HR1740 and the batch number for traceability in the operating theatre. Store in a cool, dry place below 30 °C and protected from sunlight. For special B2B volume conditions, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Product line

Premisut Prime

Material

Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)

Structure

Synthetic monofilament

Metric gauge (EP)

1.5 (EP)

Needle body

Cylindrical

Tip type

Conical (taperpoint), atraumatic

Needle size

17 mm (HR17)

Configuration

Single needle (1 × HR17)

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Manufacturer reference

P412HR1740

Medida de aguja

HR 17

Usp

4/0

Color

Violet

Medida de hilo

70 cm, 75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Suture Absorbable Monofilament Polydioxanone (PDO/PDS) Prime · Needle ½ Circle Cylindrical Body Conical Point Taperpoint HR17 17 mm · USP 4/0 (Metric 1.5) · Violet Thread 70 cm · Box of 12 units (Ref. P412HR1740 · SKU AMP412HR1740)”