Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | Needle ½ Circle Cylindrical Body Taperpoint Conical Point 17 mm (HR17) | USP 3/0 | Violet 75 cm | Box 12 units | Ref. AMP418HR1730

46,34 €

Absorbable monofilament polydioxanone (PDO/PDS) suture in Prime quality with a ½ circle needle, cylindrical body and Taperpoint conical point of 17 mm (HR17). USP gauge 3/0, violet fluted thread of 75 cm and predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Ref. AMP418HR1730, presentation in a box of 12 units, with B2B conditions for hospitals and purchasing centres.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HR1730

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range, reference AMP418HR1730, is the professional solution for the surgeon who needs a thread with prolonged absorption, excellent handling and maximum knot security during the critical phase of healing. It incorporates a ½ circle needle with cylindrical body and conical Taperpoint tip of 17 mm (HR17), grooved violet thread of 75 cm and USP gauge 3/0.

It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B supply to operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology services and purchasing centres. Commercial presentation in a box of 12 units.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer (poly(p-dioxanone)) presented in a monofilament structure, which gives it a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adhesion as there are no interstitial spaces. Its degradation occurs by hydrolysis, i.e., by scission of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days, independent of the patient’s enzymatic activity.

This prolonged absorption profile maintains the necessary tensile strength during the critical phases of healing, being especially useful in tissues that require prolonged support. The ½ circle needle with cylindrical body and conical Taperpoint tip (HR17) of 17 mm passes through tissue atraumatically, separating fibres without cutting effect: it is the reference configuration for delicate and friable tissues, with controlled passage and minimal damage along the penetration path. The grooved violet thread ensures optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference AMP418HR1730

Parameter Specification
Reference (SKU) AMP418HR1730
Factory reference P418HR1730
Quality / Brand Prime
Suture type Synthetic absorbable monofilament
Material 100 % polydioxanone (PDO/PDS), poly(p-dioxanone) polymer
Thread structure Smooth, grooved monofilament
USP / metric gauge 3/0 (metric 2)
Thread diameter 0.20 – 0.249 mm (USP/EP standard)
Thread colour Violet grooved
Thread length 75 cm (one needle)
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical Taperpoint, atraumatic
Needle size 17 mm (HR17), one needle
Absorption mechanism Hydrolysis
Total absorption 180–210 days
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units
Regulatory standard USP/EP

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial strength
4 weeks 60–70% of the initial strength
8 weeks 45% of initial strength
Total absorption 180–210 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Polydioxanone monofilament is the most well-established synthetic absorbable suture material with prolonged absorption on the market (PDS-type family). The USP 3/0 configuration, violet thread of 75 cm and ½ circle needle with conical tip of 17 mm corresponds to international reference lines; however, the presentation in a box of 12 units and the finish of the strand are specific to this reference. Below is indicated only the reference verified as comparable at category level, not interchangeable point by point:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone monofilament, USP 3/0, violet, RB-1 ½ circle taper point needle of 17 mm) Z305H Comparable by category (not interchangeable 1:1) Confirmed in official Ethicon data sheet (EPC) and authorised distributors: polymer, gauge, colour, shape and needle size (17 mm) match; they differ in strand length (70 cm vs 75 cm), tip finish (conventional taper point vs Taperpoint) and presentation (36 units vs 12 units).

There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference of the USP 3/0 / HR17 conical tip needle / 75 cm configuration; consult the technical department before use in tenders. As category equivalents (same indication and same polymer, without code verified in primary source), the violet monofilament PDO/PDS suture families from other laboratories are cited, such as the MonoPlus line from B. Braun; in all cases, the USP gauge, needle size and single-needle configuration must be verified in the manufacturer’s technical data sheet before substituting.

5. Selection tips and variants of interest

The USP 3/0 gauge is suitable for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia, muscle and ligation of medium-fine calibre vessels. The 17 mm conical tip needle is recommended for soft, well-perfused tissues where a fully atraumatic passage is sought, such as subcutaneous tissue, peritoneum, paediatric cardiovascular approximations and ophthalmology; if a controlled cutting tip is preferred for denser or fibrous tissues, consider the trocar tip (HRT) versions of the same family.

Reference Description
AM418HR1730 PDO Normal quality, HR17 needle of 17 mm, USP 3/0, violet, 70 cm (economical alternative, same configuration)
AMP418HR1730-2 PDO Prime, double needle 2xHR17 of 17 mm, USP 3/0, violet, 2×70 cm (continuous suture with anchoring at both ends)
AMP418HR1330 PDO Prime, HR13 needle of 13 mm, USP 3/0, violet, 70 cm (shorter needle, superficial planes)
AMP418HR1740 PDO Prime, HR17 needle of 17 mm, USP 4/0, violet, 70 cm (finer gauge, greater precision)
AMP418HRT1730 PDO Prime, HRT17 needle of 17 mm trocar tip (tapercut), USP 3/0, violet, 70 cm (controlled cutting tip)
AMP418HRP1730 PDO Prime, HRP17 needle of 17 mm conical Taperpoint Ultra Plus tip, USP 3/0, violet, 70 cm (premium tip finish)

All references are supplied in a box of 12 units. Keep the original packaging in a cool, dry place, respect the expiry date and handle the strand with gloves to avoid altering its mechanical properties. For special B2B conditions by volume or equivalents from other commercial houses, contact our technical-commercial team.

Additional information

Manufacturer reference

P418HR1730

Suture type

Synthetic absorbable monofilament

Material

100 % polydioxanone (PDO/PDS)

Thread structure

Smooth, grooved monofilament

Metric gauge (EP)

2

Thread diameter

0.20 – 0.249 mm (USP/EP standard)

Thread colour

Violet grooved

Needle body

Cylindrical

Needle tip

Conical Taperpoint, atraumatic

Needle size

17 mm (HR17), one needle

Swaged

Single needle (1xHR17)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 units

Regulatory standard

USP/EP

Medida de aguja

HR 17

Usp

3/0

Color

Violet

Medida de hilo

70 cm, 75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | Needle ½ Circle Cylindrical Body Taperpoint Conical Point 17 mm (HR17) | USP 3/0 | Violet 75 cm | Box 12 units | Ref. AMP418HR1730”

Your email address will not be published. Required fields are marked *