Description
1. Product Presentation
At Cahnos, we offer operating theatres, general and digestive surgery departments, paediatric cardiovascular surgery units, ophthalmology departments and hospital purchasing centres the PDO/PDS absorbable monofilament polydioxanone suture from the Prime range, reference P418HR2630-2 (SKU AMP418HR2630-2). This is a prolonged-absorption thread with a very competitive quality-to-performance ratio for institutional B2B procurement.
This presentation combines a double ½-circle needle with cylindrical body and 26 mm Taperpoint conical tip (2×HR 26 Prime profile), a 70 cm violet monofilament thread and USP 3/0 gauge: a highly versatile profile for soft tissue approximation, ligatures and precision procedures on delicate structures. Each unit is supplied sterile, ready to use and single-use, in a box of 12 units.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polymer — poly(p-dioxanone) — with a monofilament structure that degrades by hydrolysis, i.e., by cleavage of the polymer chains on contact with organic fluids, over a predictable period of 180 to 210 days, independent of the patient’s enzymatic activity. It is the longest absorption profile among conventional synthetic absorbable sutures, making it ideal for slow-healing tissues or those under sustained tension.
Being a monofilament, the thread has a smooth, grooved surface that reduces friction as it passes through tissue, minimises the sawing effect and hinders bacterial adhesion, while maintaining high tensile strength and reliable knot tying during the critical phases of healing. The ½-circle needle with cylindrical body and Taperpoint conical tip separates fibres without a cutting effect, being especially atraumatic on delicate structures such as vessels, parenchyma, paediatric cardiovascular tissue and ocular tissue. The double-needle format allows suturing in both directions and continuous suturing without rethreading. The violet colour provides optimal visibility over the surgical field. The product is sterilised with ethylene oxide, is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| SKU Cahnos | AMP418HR2630-2 |
| Factory reference | P418HR2630-2 |
| Material | Polydioxanone (PDO/PDS), poly(p-dioxanone) synthetic monofilament |
| Thread structure | Monofilament (not braided), grooved finish |
| Quality | Prime (range PREMISUT) |
| Gauge | USP 3/0 (metric EP 2) |
| Thread colour | Violet, high surgical visibility |
| Thread length | 70 cm (1 thread · 2 needles per unit) |
| Swaged | Double needle (2×HR 26), one needle at each end of the thread |
| Needle shape | ½ circle (half circumference) |
| Needle body | Cylindrical |
| Tip type | Conical Taperpoint (atraumatic), grooved |
| Needle size | HR 26 Prime – 26 mm |
| Absorption mechanism | Hydrolysis; complete absorption between 180 and 210 days |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | Between 180 and 210 days by hydrolysis, with minimal tissue reaction |
Excellent tensile strength, optimal knot tying and a fully predictable absorption rate, with prolonged tissue support during the critical healing phase.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Monofilament polydioxanone is the most well-established prolonged-absorption synthetic absorbable suture raw material on the market (PDS-type lines). There is no equivalence table officially validated by the manufacturer declaring a 1:1 correspondence with other brands; the verified references listed below are comparable at category level, not interchangeable point by point, and must be checked field by field (material, gauge, length, colour, curvature, needle size and tip) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II® – violet monofilament polydioxanone, USP 3/0, 70 cm, 26 mm SH needle, ½ circle, conical tip (taper point) | Z316H | Comparable by category (not interchangeable 1:1) | Material (polydioxanone), USP 3/0 gauge, ½-circle curvature, conical tip, 26 mm needle size, violet colour and thread length (70 cm) coincide; the configuration (single SH needle versus double 2×HR 26 needle) and the presentation (box of 36 versus 12 units) differ. Verified in the official Ethicon catalogue and authorised distributors. Confirm the IFU and CE/MDR classification before substituting. |
| B. Braun (Aesculap) | MonoPlus® – uncoated violet monofilament polydioxanone, USP 3/0 (EP 2), 70 cm, 26 mm HR26 Easyslide needle, ½ circle, round body, conical tip | C2024025 / G2024025 | Comparable by category (not interchangeable 1:1) | Material (polydioxanone), USP 3/0 (EP 2) gauge, 26 mm HR26 needle, ½-circle curvature, conical tip, violet colour and thread length (70 cm) coincide; the configuration (single versus double needle) and the needle finish (Easyslide versus Taperpoint) differ. Verified in the official B. Braun catalogue. Confirm the IFU and CE/MDR classification before substituting. |
There is no manufacturer-validated equivalence table for an exact 1:1 match with the double Taperpoint conical needle in USP 3/0 gauge; consult the technical department before use in tenders. As homologous market families, to be verified reference by reference in their official datasheet before substitution, the following are cited: the PDS II® / PDS Plus® lines from Ethicon, the MonoPlus® line from B. Braun, the Surgicryl PDO line from SMI and the PDO lines from DemeTECH, checking in each case the USP 3/0 gauge, ½-circle curvature, 26 mm needle size (tolerance ±1 mm), conical tip, 70 cm length, violet colour and double configuration. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) offers an excellent balance between tensile strength and reduced tissue trauma, being highly versatile for skin, subcutaneous tissue, mucosa, superficial fascia, soft tissue approximation, ligation of small-calibre vessels and precision procedures in ophthalmology and paediatric cardiovascular surgery. The 26 mm ½-circle needle with Taperpoint conical tip ensures atraumatic entry into delicate, well-vascularised tissues; if greater penetration is required in firm or slightly fibrous tissues, consider the trocar-tip versions (Tapercut, HRT series) of the same family. The double configuration facilitates continuous sutures and bidirectional approximation; if the protocol prefers interrupted sutures, the family offers single-needle versions.
| Reference (SKU) | Description |
|---|---|
| AMP418HR2630-2 | PDO Prime, double HR 26 mm needle, Taperpoint conical tip, USP 3/0, violet, 70 cm (current product) |
| AMP412HR2630 | PDO Prime, single HR 26 mm needle, conical tip, USP 3/0, violet, 75 cm |
| AMP412HR2630.2 | PDO Prime, HR 26 mm taperpoint needle, USP 3/0, violet, 2×75 cm (double thread) |
| AMP418HR2630VB | PDO Prime VisiBlack, double needle HR 26 mm conical tip, USP 3/0, violet, 70 cm |
| AMP418HRP2630-2 | PDO Prime, double needle HRP 26 mm taper point Ultra Plus, USP 3/0, violet, 70 cm |
| AMP418FR2630-2 | PDO Prime, double needle 5/8 FR 26 mm taper point Taperpoint, USP 3/0, violet, 70 cm |
| AMP418RR2610.2 | PDO Prime, double needle HR 26 mm taper point, USP 0, violet, 2×70 cm (larger gauge) |
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre, and store in a cool, dry place, protected from direct sunlight. For special B2B conditions by volume, hospital traceability or validation of equivalents from other commercial houses, contact our technical-commercial team at Cahnos.