Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture, reference AM413HR4801, is the reference choice for hospitals, private clinics, operating theatres and purchasing groups that need a long-lasting absorbable synthetic thread with a highly competitive quality-price ratio. This reference combines a 1/2 circle needle with cylindrical body and Taperpoint conical point, 48 mm (HR48), USP 1 gauge (metric 4) and a 90 cm violet thread. It is supplied sterile and ready to use, in a box of 12 units, with predictable absorption between 180 and 210 days and tensile strength retention designed for tissues requiring prolonged wound support.
2. Technical explanation of the product and procedure
Polydioxanone is an absorbable synthetic polymer (poly(p-dioxanone)) that degrades by hydrolysis on contact with organic fluids, with minimal inflammatory response and without depending on the patient’s enzymatic activity. Its monofilament structure with grooved finish offers a smooth and regular passage through tissue, without sawing effect or capillarity, which reduces microorganism drag and tissue reaction compared with braided threads.
The 1/2 circle needle with cylindrical body and Taperpoint conical point (HR 48 mm profile) passes through soft tissues by separating the fibres without cutting them, minimising tissue trauma in deep planes, fascia and confined surgical fields. USP 1 gauge (metric 4) provides high initial strength, suitable for fascia, aponeurosis, muscle planes and closures under high tension. The violet colouring ensures optimal visibility of the thread throughout the procedure. Sterile single-use product, not suitable for resterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AM413HR4801
| Characteristic | Specification |
| Reference (SKU) | AM413HR4801 (ref. 413HR4801) |
| Material | Polydioxanone (PDO/PDS), synthetic monofilament |
| Thread structure | Monofilament with grooved finish |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet (high visibility) |
| Needle shape | 1/2 circle |
| Needle body and point | Cylindrical body, conical Taperpoint tip |
| Needle size | 48 mm (HR 48) |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 180-210 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues, fascia and ophthalmology |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology.
4. Equivalences and Cross-References
Monofilament polydioxanone is the most widely used family of long-lasting absorbable sutures on the market. This reference is clinically positioned in the same category as the international PDO lines verified in authorised distribution catalogues, in the closest configuration (USP 1, 1/2 circle 48 mm needle, violet thread):
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone) monofilament | W9299T | Comparable by category (not interchangeable 1:1) | Same polymer (PDO), USP 1 gauge, 1/2 circle 48 mm needle and violet thread; the point differs (reverse cutting triangular vs. Taperpoint conical) and the manufacturer-declared absorption (182-238 days). |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone) monofilament | Z569T | Comparable by category (not interchangeable 1:1) | Same CPX 48 mm 1/2 circle needle, USP 1 and violet colour; the thread length differs (70 cm vs. 90 cm) and the point profile (reverse cutting vs. Taperpoint conical). |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. For any formal substitution, the material, gauge (USP 1), needle geometry and size (1/2 circle, cylindrical body, conical point, 48 mm radius), thread length (90 cm), colour and regulatory classification of each reference must be verified one by one, since small variations in needle radius or point prevent a 1:1 equivalence. As counterparts in the prolonged absorption category, the PDS II and PDS Plus lines from Ethicon and MonoPlus from B. Braun are also cited, whose specific codes in the exact configuration of Taperpoint conical needle HR 48 mm with 90 cm thread are pending confirmation against the manufacturer’s official source.
5. Selection tips and variants of interest
Choose this suture when the tissue requires prolonged wound support (absorption of 6-7 months): abdominal wall, fascia, intestinal anastomoses, ligament and tendon repair, and paediatric cardiovascular surgery. The Taperpoint conical point offers an ideal atraumatic entry for soft tissues and delicate structures; if the procedure requires greater penetration into firm tissues, consider a reverse cutting triangular point needle from the same family. For tissues with shorter healing (2-4 weeks), consider the PGA or PGCL families from the same catalogue. Within the PDO family from Cahnos, the following variants of interest are available:
| Reference | Recommended variant |
| AMP413HR4801 | PDO Prime USP 1, HR 48 mm conical needle, violet, 90 cm (same configuration in Prime quality) |
| AMP413HR4801.2 | PDO Prime USP 1, conical needle HR 48 mm, violet, 2 x 90 cm (double thread format with high cost-effectiveness) |
| AMP413HR4001 | PDO Prime USP 1, conical needle HR 40 mm, violet, 90 cm (shorter needle) |
| AMP413HRP4801 | PDO Prime USP 1, Ultra Plus HRP 48 mm conical needle, violet, 90 cm (reinforced point) |
| AMP413HRN4501 | PDO Prime USP 1, HRN45 blunt point needle, 45 mm, violet, 90 cm (even more atraumatic entry) |
| AMP313HR4801 | PGCL monofilament USP 1, HR 48 mm needle, violet, 90 cm (average absorption 90-120 days) |
All references are supplied in a box of 12 units. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight.