Description
1. Introduction
The Prime range absorbable monofilament polydioxanone (PDO/PDS) suture is the reference choice for the surgical professional who demands a prolonged absorption thread, predictable handling and maximum knot security during the critical phase of healing. This presentation incorporates double ½ circle needle with cylindrical body and Taperpoint Ultra Plus conical point, 17 mm (2xHRP17), violet thread of 70 cm and USP 4/0 (metric 1.5) gauge.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B procurement for operating theatres, general surgery services, paediatric cardiovascular surgery units, ophthalmology services and purchasing centres. Commercial presentation in a box of 12 units.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— presented in a monofilament structure. This configuration gives the thread a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence as there are no interstitial spaces. Its degradation occurs by hydrolysis, i.e., by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days and independent of the patient’s enzymatic activity, with minimal tissue reaction.
The ½ circle needle with cylindrical body and Taperpoint Ultra Plus conical point passes through tissue atraumatically, separating the fibres without a cutting effect; the Ultra Plus variant provides precision sharpening that facilitates passage through delicate and well-perfused tissues. The double armed configuration (2xHRP17) allows continuous suturing with anchoring at both ends, very common in laparoscopy and in continuous layer suturing techniques. The violet colour guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference P418HRP1740-2
| Parameter | Specification |
| Factory reference | P418HRP1740-2 |
| Reference Cahnos (SKU) | AMP418HRP1740-2 |
| Quality / range | Prime (premium range) |
| Material | Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone) |
| Thread structure | Synthetic monofilament |
| USP / metric gauge | 4/0 (metric 1.5) |
| Thread colour | Violet (high visibility) |
| Thread length | 70 cm (double needle) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint Ultra Plus, atraumatic |
| Needle size | 17 mm (2 x HRP17) |
| Configuration | Double needle (2 x HRP17) |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 units |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 4 weeks | 60-70 % of the initial tensile strength |
| 8 weeks | 45 % of the initial tensile strength |
| Total absorption | 180-210 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Monofilament polydioxanone is the most well-established synthetic absorbable suture material with prolonged absorption on the market (PDS-type family). For the verified configuration of this data sheet (double ½ circle cylindrical needle with conical point of 17 mm, USP 4/0 gauge, violet thread of 70 cm), the following commercial references from other manufacturers have been cross-checked against primary sources (official manufacturer catalogue and official product data sheet):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun | MonoPlus® — monofilament polydioxanone, violet, USP 4/0 (1.5), 70 cm, double ½ circle needle of 17 mm, conical point (taper point) | C0024614 | Comparable by category (not interchangeable 1:1) | Verified in the official B. Braun catalogue: polymer, gauge, colour, length, ½ circle curvature, conical point type, needle size (17 mm) and double armed configuration match; the point finish differs (Taperpoint Ultra Plus versus conventional conical) and the commercial presentation. |
| Ethicon (Johnson & Johnson MedTech) | PDS® II — monofilament polydioxanone, USP 4/0, violet, 70 cm, RB-1 ½ circle needle, conical taper point, 17 mm | Z304H | Comparable by category (not interchangeable 1:1) | Confirmed in the official Ethicon data sheet (EPC) and authorised distributors: polymer, USP 4/0 gauge, colour, length, curvature, conical point and needle size (17 mm) match; the armed configuration differs (single RB-1 needle versus double needle) and the presentation (36 units versus 12 units). |
| Ethicon (Johnson & Johnson MedTech) | PDS® II D-special — monofilament polydioxanone, double RB-1 needle of 17 mm in ½ circle, conical point, USP 4/0, violet, 90 cm | D6261 | Comparable by category (not interchangeable 1:1) | Code confirmed in the official Ethicon catalogue: material, gauge, colour, 17 mm conical point and double armed configuration match; the thread length differs (90 cm versus 70 cm) and the point finish. |
| Ethicon (Johnson & Johnson MedTech) | PDS® Plus Antibacterial — polydioxanone with antibacterial coating (triclosan), USP 4/0, violet, 70 cm, RB-1 needle of 17 mm, ½ circle, conical point | PDP304H | Comparable by category (not interchangeable 1:1) | Same configuration of gauge, colour, length and 17 mm needle; fundamental difference: antibacterial triclosan coating and single armed versus double needle. Verify IFU. |
There is no equivalence table validated by the manufacturer that declares this reference as interchangeable 1:1 with other brands; consult the technical department before use in tenders. As homologous families in the sector, the PDS® II and PDS® Plus lines from Ethicon are cited, as well as the MonoPlus® line from B. Braun; in all cases, the USP gauge, curvature, body, point, needle size, armed configuration and thread length must be verified code by code in the official technical data sheet and IFU before any substitution. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
The USP 4/0 (metric 1.5) gauge is suitable for fine tissues and low-to-medium tension: skin, subcutaneous tissue, mucosa, microsurgery, fine vascular ligatures and precision approximations, with special application in ophthalmology and paediatric cardiovascular surgery. The double armed 2×70 cm facilitates continuous suturing with anchoring at both ends, very useful in laparoscopy and deep planes; if the protocol requires interrupted sutures, consider single strand versions of the same family. The 17 mm conical point needle is the most atraumatic option for soft and well-perfused tissues; if denser or fibrous tissues need to be penetrated, consider the trocar point versions (Tapercut, HRT) of the same family.
| Reference (SKU) | Description |
| AMP418HRP1740-2 | PDO Prime, double needle 2xHRP17 conical Ultra Plus point, USP 4/0, violet, 70 cm (this product) |
| AMP418HRP1740 | PDO Prime, HRP17 needle conical Ultra Plus point, USP 4/0, violet, 70 cm (single armed) |
| AMP418HR1740-2 | PDO Prime, double needle 2xHR17 conical point, USP 4/0, violet, 2×70 cm (conventional conical point) |
| AM418HR1740-2 | PDO Normal quality, double needle 2xHR17 conical point, USP 4/0, violet, 2×70 cm (economical alternative) |
| AMP413HRP1730-2 | PDO Prime, double needle 2xHRP17 conical Ultra Plus point, USP 3/0, violet, 90 cm (larger gauge) |
| AMP418HRT1740 | PDO Prime, HRT17 17 mm trocar point (tapercut) needle, USP 4/0, violet, 70 cm (cutting point) |
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference P418HRP1740-2 and the batch number for traceability in the operating theatre. Store in a cool, dry place, below 30 °C and protected from sunlight. For special B2B volume conditions, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.