We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture | ½ Circle Cylindrical Body Needle, Ultra Plus Conical Point HRP 22 mm | USP 0 Gauge (Metric 3.5) | Violet Thread 70 cm | Box of 12 Units

89,92 €

Absorbable monofilament polydioxanone (PDO/PDS) suture in Prime quality, with a ½ circle needle with cylindrical body and fluted Ultra Plus conical point of 22 mm (HRP 22), USP 0 gauge (metric 3.5) and 70 cm violet thread. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 and 45% at 8. Sterile by ethylene oxide, with minimal tissue reaction and excellent knot security; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Factory reference P418HRP2210 · presentation in a box of 12 units (SKU AMP418HRP2210).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HRP2210

Description

1. Product Presentation

At Cahnos we offer the absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range, reference P418HRP2210 (SKU AMP418HRP2210), designed for the professional who needs a thread with prolonged absorption, excellent handling and maximum knot security. This presentation combines a ½ circle needle with cylindrical body and fluted Ultra Plus conical point of 22 mm (HRP 22 Prime), a USP 0 gauge (metric 3.5) and a 70 cm violet thread.

It is the reference solution for B2B supply to operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology services and purchasing centres. Synthetic absorbable medical device, sterile and single-use, with a very competitive quality-to-performance ratio. Commercial presentation in a box of 12 units.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer with a monofilament structure that degrades by hydrolysis, i.e. by cleavage of the polymer chains on contact with organic fluids, over a predictable period of 180 to 210 days. Being a monofilament, the thread has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, while maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.

The ½ circle needle with cylindrical body and fluted Ultra Plus conical point passes through tissue by separating the fibres without a cutting effect, making it especially atraumatic in delicate structures (vessels, parenchyma, paediatric cardiovascular tissue) and in precision procedures such as ophthalmology. The product is sterilised by ethylene oxide, is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference AMP418HRP2210

Parameter Specification
Material Polydioxanone (PDO/PDS), poly(p-dioxanone) synthetic monofilament
Quality Prime (premium range)
Gauge USP 0 (metric 3.5)
Thread colour Violet
Thread length 70 cm
Needle shape ½ circle (half circumference)
Needle body Cylindrical
Tip type Conical Ultra Plus grooved (Taperpoint)
Needle size RHRP 22 – 22 mm
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Factory reference P418HRP2210
SKU Cahnos AMP418HRP2210
Presentation Box of 12 units

3.2. Tensile strength retention profile

Period after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %

Complete absorption by hydrolysis within 180 to 210 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most well-established synthetic absorbable suture material with prolonged absorption on the market. For the USP 0 configuration, ½ circle conical point needle and 70 cm violet thread, the following catalogue correspondence has been verified, with the caveat that commercial market assemblies present differences in point finish or needle size, and therefore it is not interchangeable 1:1:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone), USP 0, violet, 70 cm, CT-2 needle of 26 mm, ½ circle, conical point (taper point) Z334H Comparable by category (not interchangeable 1:1) They match in material, USP 0 gauge, colour and thread length (70 cm). They differ in needle size (26 mm vs 22 mm) and point finish (standard taper point vs fluted Ultra Plus conical point of this reference). Different commercial presentation (36 units vs 12 units). Reference verified against official catalogues and authorised distributors.

There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference with fluted Ultra Plus conical point in USP 0 gauge; consult the technical department before use in tenders. As homologous market families to verify in their official datasheet before substitution, the MonoPlus line from B. Braun (monofilament polydioxanone) and the PDS II / PDS Plus ranges from Ethicon are cited, checking reference by reference the USP 0 gauge, the 22 mm ½ circle needle size, the conical point type, the 70 cm length and the violet colour.

5. Selection tips and variants of interest

USP 0 gauge (metric 3.5) is indicated for tissues with moderate-to-high tension: fascia, aponeurosis, abdominal wall, subcutaneous tissue and ligation of medium-calibre vessels. The ½ circle needle with fluted Ultra Plus conical point is the most atraumatic option for delicate tissues; if you need the same absorption profile with reinforced penetration point in firm or slightly fibrous tissues, consider the trocar point (Tapercut) versions of the same family.

Variants of interest in the Cahnos catalogue (all in boxes of 12 units):

Reference Description
AMP418HRP2210 PDO Prime, HRP 22 mm needle, Ultra Plus conical point, USP 0, violet, 70 cm (current product)
AMP418HRP2220 PDO Prime, HRP 22 mm needle, Ultra Plus conical point, USP 2/0, violet, 70 cm (finer gauge)
AMP418HRP2230 PDO Prime, HRP 22 mm needle, Ultra Plus conical point, USP 3/0, violet, 70 cm
AMP418HRP2240 PDO Prime, HRP 22 mm needle, Ultra Plus conical point, USP 4/0, violet, 70 cm (greater precision)
AMP418HR2210 PDO Prime, HR 22 mm needle, Taperpoint conical point (without Ultra Plus), USP 0, violet, 70 cm
AMP418HRP2230-2 PDO Prime, HRP 22 mm needle, Ultra Plus conical point, double needle, USP 3/0, violet, 70 cm

Keep the original packaging in a dry, cool place, respect the expiry date and handle the thread with gloves to avoid altering its mechanical properties. For special B2B conditions, volume orders and hospital traceability, contact our technical-commercial team.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament

Gauge

USP 0 (metric 3.5)

Needle body

Cylindrical

Needle tip

Conical Ultra Plus grooved (Taperpoint)

Needle size

HRP 22 – 22 mm

Sterilisation

Ethylene oxide, single-use

Manufacturer reference

P418HRP2210

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular and ophthalmology

Medida de aguja

HRP 22, RHRP 22 prime

Usp

0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical, Cylindrical flat tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture | ½ Circle Cylindrical Body Needle, Ultra Plus Conical Point HRP 22 mm | USP 0 Gauge (Metric 3.5) | Violet Thread 70 cm | Box of 12 Units”

Your email address will not be published. Required fields are marked *