We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ½ Circle Cylindrical Body Conical Point Needle HR55 (55 mm) · USP Gauge 0 · Violet Thread 150 cm in Loop · Box 12 units · Ref. P415HR55L10

69,36 €

Absorbable monofilament polydioxanone (PDO/PDS) Prime suture in loop format, with a ½ circle needle with cylindrical body and conical Taperpoint point of 55 mm (HR55), USP gauge 0 and violet thread of 150 cm. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 and 45% at 8. Sterilised by ethylene oxide, single-use and minimal tissue reaction: indicated for approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissue and ophthalmology. Manufacturer reference P415HR55L10 · SKU AMP415HR55L10, in a box of 12 sterile units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP415HR55L10

Description

1. Product Presentation

The Prime absorbable monofilament polydioxanone (PDO/PDS) suture from Cahnos, factory reference P415HR55L10 (SKU AMP415HR55L10), is the long-lasting solution your operating theatre needs for soft tissue approximation, ligatures and continuous wall closures. It combines a ½ circle cylindrical body needle with a 55 mm Taperpoint conical tip (HR55), USP 0 gauge and a 150 cm violet thread mounted in a loop, all in a presentation of a box of 12 sterile units. Ideal for general surgery departments, paediatric cardiovascular surgery operating theatres and ophthalmology units seeking a synthetic absorbable suture with prolonged absorption and a very competitive quality-price ratio.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polyester (poly(p-dioxanone) polymer) that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees very reproducible absorption kinetics. Being a monofilament, the thread has no wicking effect or capillary edges: it reduces bacterial adherence, minimises tissue sawing and facilitates sliding through tissue, with a firm feel and excellent knot security. The ½ circle needle with cylindrical body and conical tip (Taperpoint) separates the fibres without cutting them, offering progressive and atraumatic entry into soft and well-vascularised tissues. The 150 cm loop format allows the first stitch to be placed and the continuous suture to be anchored without rethreading, a clinically relevant advantage in reduced surgical fields. The violet colouration ensures optimal visibility of the thread throughout the procedure.

3. Technical Specifications

3.1. General characteristics

Material Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone)
Quality / range Prime (range PREMISUT)
Gauge / size USP 0 (metric 3.5)
Thread colour Violet (high visibility)
Thread length 150 cm in loop format
Needle shape ½ circle (half circumference), cylindrical body
Tip type Conical point / Taperpoint
Needle size HR55 (55 mm)
Absorption mechanism Hydrolysis
Absorption period 180-210 days
Sterilisation Ethylene oxide (EO), single-use, not for re-sterilisation
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Soft tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units
Factory reference / SKU P415HR55L10 / AMP415HR55L10
Regulatory standard Complies with USP/EP Pharmacopoeia; CE marking as a medical device

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %
Complete absorption 180-210 days by hydrolysis

This prolonged force retention profile is maintained during the critical healing phase of slow-recovering tissues, and is therefore recommended for closure of fascia, aponeurosis and structures subject to sustained tension.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). For this specific configuration (½ circle cylindrical needle with conical tip HR55 of 55 mm, USP 0 gauge, 150 cm violet thread in loop), the existence of homologous lines has been verified against primary manufacturer sources and the GUDID/FDA regulatory database:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS Plus (polydioxanone with triclosan) — violet monofilament PDP9261G Comparable by category (not interchangeable 1:1) Material matches (violet PDO monofilament), USP 0 gauge and 150 cm loop format, with the exception of the antimicrobial triclosan coating (PDS Plus) and the needle size (48 mm conical versus HR55 of 55 mm). Code verified in GUDID.
B. Braun / Aesculap (US distribution, e.g. McKesson) MonoPlus (polydioxanone) — loop with needle B0024094 Comparable by category (not interchangeable 1:1) Material matches (PDO monofilament), USP 0 gauge, 150 cm and loop format; the needle is 65 mm in that reference versus HR55 of 55 mm. Verify your distributor’s presentation and packaging before substituting.

There is no manufacturer-validated equivalence table for cross-brand substitution in the exact configuration of HR55 conical-tip needle of 55 mm with 150 cm loop and USP 0 gauge; consult the technical department before use in tenders. For any formal substitution, the material, gauge (USP 0), needle size and geometry (½ circle, cylindrical body, conical tip, 55 mm radius), thread length and format (150 cm, loop), colour and CE/MDR regulatory classification of each reference must be verified one by one. The reference homologous prolonged-absorption polydioxanone lines in the sector include PDS II and PDS Plus from Ethicon, MonoPlus from B. Braun/Aesculap, Surgicryl PDO from SMI and Maxon from Medtronic/Covidien, all comparable at category level and not interchangeable 1:1, pending code-by-code verification against their official technical data sheet.

5. Selection tips and variants of interest

USP 0 gauge (metric 3.5) is highly versatile: suitable for subcutaneous tissue, superficial muscular planes, fascial closure and ligation of medium-calibre vessels. The ½ circle needle with 55 mm conical tip (HR55) offers an intermediate radius between HR50 and HR65, ideal for deep planes with limited access and the abdominal wall. The 150 cm loop format facilitates long continuous sutures and multiple ligatures without rethreading. Within the same PDO Prime loop family, the following variants are available:

Reference Variant of interest
AMP415HR65L10 (P415HR65L10) PDO Prime, HR65 needle of 65 mm, USP 0, 150 cm violet loop (larger needle radius)
AM415HR50L10 (415HR50L10) Standard PDO, HR50 conical needle of 50 mm, USP 0, 150 cm violet loop (smaller needle radius)
AMP415HR65L01 (P415HR65L01) PDO Prime, HR65 needle of 65 mm, USP 1, 150 cm violet loop (larger gauge for higher tension)
AMP415HR30L20 (P415HR30L20) PDO Prime, HR30 needle of 30 mm, USP 2/0, 150 cm violet loop (reduced access and delicate tissue)

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or validation of equivalences from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone)

Quality

Prime (range PREMISUT)

Gauge

USP 0 (metric 3.5)

Thread length

150 cm in loop format

Needle shape

½ circle, cylindrical body

Tip type

Conical / Taperpoint

Needle size

HR55 (55 mm)

Absorption mechanism

Hydrolysis, 180-210 days

Sterilisation

Ethylene oxide (EO), single-use

Indications

Soft tissue approximation, ligatures, general surgery, paediatric cardiovascular, ophthalmology

Presentation

Box of 12 units

Manufacturer reference

P415HR55L10

Regulatory standard

USP/EP Pharmacopoeia; CE marking

Medida de aguja

HR 55

Usp

0

Color

Violet

Medida de hilo

150 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ½ Circle Cylindrical Body Conical Point Needle HR55 (55 mm) · USP Gauge 0 · Violet Thread 150 cm in Loop · Box 12 units · Ref. P415HR55L10”

Your email address will not be published. Required fields are marked *