We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture – ½ Circle Cylindrical Body Conical Point Taperpoint Ultra Plus 17 mm (HRP17) – USP 0 – Violet 70 cm – Box 12 units

89,92 €

Absorbable monofilament Polydioxanone (PDO/PDS) suture Prime quality, with a ½ circle needle with cylindrical body and Taperpoint Ultra Plus conical point of 17 mm (HRP17). USP 0 gauge, violet thread of 70 cm, predictable absorption by hydrolysis in 180–210 days and tensile strength retention of 75 % at 2 weeks. Sterile by ethylene oxide, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Factory reference P418HRP1710, presentation in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HRP1710

Description

1. Introduction

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range is the reference choice for the surgical professional who needs a thread with prolonged absorption, maximum knot security and excellent tension retention during the critical healing phase. It incorporates a ½ circle needle with cylindrical body and Taperpoint Ultra Plus conical point of 17 mm (HRP17), violet thread of 70 cm and USP 0 gauge.

It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B supply to operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology services and purchasing centres. Commercial presentation in a box of 12 units.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer (poly(p-dioxanone)) presented in a monofilament structure, which gives it a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence. Its degradation occurs by hydrolysis, i.e., by scission of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days. This prolonged absorption profile maintains the necessary tensile strength during the critical phases of healing, being especially useful in tissues that require prolonged support.

The ½ circle needle with cylindrical body and Taperpoint Ultra Plus conical point passes through tissue atraumatically, with clean penetration and minimal tissue damage; the Ultra Plus variant provides precision sharpening that facilitates passage through delicate and well-perfused tissues. The code HRP17 corresponds to a 17 mm long needle mounted in a single-needle configuration. The product is sterilised by ethylene oxide, is single-use and does not allow re-sterilisation.

3. Technical Specifications

Parameter Specification
Material Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)
Thread structure Synthetic monofilament
Quality Prime (Premium range)
Gauge USP 0
Thread colour Violet
Needle shape 1/2 circle
Needle body Cylindrical
Tip type Conical Taperpoint Ultra Plus
Needle size HRP 17 (17 mm), one needle
Thread length 70 cm
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (EO), single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units
Factory reference P418HRP1710
SKU Cahnos AMP418HRP1710

Tensile strength retention profile

Period Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %

Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most well-established synthetic absorbable suture raw material with prolonged absorption on the market. The USP 0 configuration, 70 cm violet thread and ½ circle needle with conical point of 17 mm finds correspondence in international reference lines; however, the commercial needles of those lines usually mount different gauges and lengths to the HRP17 of 17 mm:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS Plus (polydioxanone with triclosan) – RB-1 needle, ½ circle, conical point, 17 mm, USP 2/0, 90 cm PDP9108H / PDP9109H Comparable by category (not interchangeable 1:1) Same base polymer, needle shape and size (½ circle, conical point, 17 mm); they differ in gauge (USP 2/0 vs 0), thread length (90 cm vs 70 cm) and the antibacterial triclosan coating of PDS Plus. Presentation 36 units.
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone) – RB-1 needle, ½ circle, conical point, 17 mm, USP 3/0, 70 cm Z305H Comparable by category (not interchangeable 1:1) They match in polymer, colour, needle shape and size (½ circle, conical point, 17 mm) and thread length (70 cm); the gauge differs (USP 3/0 vs 0). Presentation 36 units.

There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference of the USP 0 / HRP17 needle / 70 cm configuration; consult the technical department before use in tenders. As category equivalents (same indication and same polymer, without a code verified in a primary source), the violet monofilament PDO/PDS suture families from other laboratories are cited, such as the MonoPlus line from B. Braun; in all cases, the USP gauge, needle size and single-needle configuration must be verified in the manufacturer’s technical data sheet before substituting.

5. Selection tips and variants of interest

USP 0 gauge is used in tissues with moderate-high tension and in ligatures of medium-calibre vessels; the 17 mm conical point needle is recommended in soft, well-perfused tissues where an atraumatic passage is sought, such as subcutaneous tissue, fascia, peritoneum and paediatric cardiovascular approximations. If a controlled cutting point is preferred for denser tissues, consider the trocar point versions of the same family (HRT).

Reference Description
AMP418HRP1720 PDO Prime, HRP17 needle of 17 mm Ultra Plus conical point, USP 2/0, violet, 70 cm (higher gauge)
AMP418HRP1730 PDO Prime, HRP17 needle of 17 mm Ultra Plus conical point, USP 3/0, violet, 70 cm (general surgery)
AMP418HRP1740 PDO Prime, HRP17 needle of 17 mm Ultra Plus conical point, USP 4/0, violet, 70 cm (greater precision)
AMP418HRP1750 PDO Prime, HRP17 needle of 17 mm Ultra Plus conical point, USP 5/0, violet, 70 cm (fine gauge, ophthalmology)
AMP418HRT1730 PDO Prime, HRT17 needle of 17 mm trocar point (tapercut), USP 3/0, violet, 70 cm (cutting point)

All references are supplied in a box of 12 units. Keep the original packaging in a dry, cool place, respect the expiry date and handle the strand with gloves to avoid altering its mechanical properties. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)

Structure

Synthetic monofilament

Quality

Prime (Premium range)

Needle body

Cylindrical

Needle tip

Conical Taperpoint Ultra Plus

Needle size

HRP 17 (17 mm), one needle

Sterilisation

Ethylene oxide (EO), single-use

Indications

General surgery, paediatric cardiovascular tissues, ophthalmology, ligatures

Presentation

Box of 12 units

Manufacturer reference

P418HRP1710

Medida de aguja

HRP 17

Usp

0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical, Cylindrical flat tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture – ½ Circle Cylindrical Body Conical Point Taperpoint Ultra Plus 17 mm (HRP17) – USP 0 – Violet 70 cm – Box 12 units”

Your email address will not be published. Required fields are marked *