Description
1. Introduction
The Absorbable Monofilament Suture PREMISUT PDO/PDS Polydioxanone in its Prime version is the reference choice for professionals who need a long-lasting, fine thread with predictable handling in delicate tissues. This presentation mounts a ½ circle needle with reverse cutting triangular body and point of 16 mm (HS16 profile), USP 5/0 gauge and violet grooved thread of 75 cm: a balanced configuration for general, paediatric and ophthalmological surgery that combines penetration power in firm tissues with minimal tissue trauma.
It is supplied sterile, ready for single use, in a box of 12 units, in a B2B format aimed at hospital replenishment, purchasing centres and public tenders.
2. Technical Explanation
Polydioxanone (PDO) is a synthetic absorbable polyester, a polymer composed of poly(p-dioxanone), which is presented in a monofilament structure: this configuration reduces the sawing effect when passing through tissue, minimises bacterial adherence and offers excellent tensile strength and knot security. Its absorption occurs by hydrolysis over a range of 180 to 210 days, without depending on tissue enzymes, which guarantees predictable mass loss and minimal tissue reaction.
The ½ circle needle with reverse cutting triangular point combines the penetration of a cutting point with a triangular body that avoids tearing of adjacent tissue: it is the indicated choice for skin, fascia and tissues of a certain consistency. The violet grooved colour of the thread improves its visibility over the surgical field.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Thread material | Polydioxanone (PDO/PDS), synthetic polymer of poly(p-dioxanone) |
| Structure | Grooved monofilament |
| Suture type | Long-term synthetic absorbable |
| Gauge / size | USP 5/0 |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Fluted violet |
| Needle shape | ½ circle (half circumference) |
| Tip type | Triangular reverse cutting (reverse cutting), body and point |
| Needle size | 16 mm (HS 16 Prime profile) |
| Swaged | 1 needle per suture |
| Range / quality | Prime (premium range) |
| Absorption | By hydrolysis in 180-210 days |
| Tissue reaction | Minimal |
| Sterilisation | Ethylene oxide (EO), single-use, not re-sterilisable |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Article reference | P412HS1650 |
| SKU Cahnos | AMP412HS1650 |
Tensile strength retention profile:
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
| Complete absorption | 180-210 days by hydrolysis |
The strength retention profile is maintained during the critical phase of healing of slow-healing tissues, which recommends its use in closures of fascia, aponeurosis and structures subjected to sustained tension.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures. Against the verified configuration of this datasheet (½ circle needle with reverse cutting triangular body and point of 16 mm, USP 5/0 gauge, violet thread of 75 cm) the homologous families of PDS® II and PDS Plus® (polydioxanone monofilament, violet, uncoated and with triclosan respectively) and MonoPlus® from B. Braun/Aesculap, as well as the Surgicryl PDO line from SMI have been compared.
In the PDS II range from Ethicon the available ½ circle triangular needles are 22 mm (OS-4) and 40/48 mm (CP/CPX), so there is no exact match of size (16 mm) and point for gauge 5/0; in B. Braun/Aesculap the same configuration requires code-by-code verification in their official catalogue. There is no equivalence table validated by the manufacturer; consult with the technical department before use in tenders. The guaranteed 1:1 interchangeability remains within the Prime range itself.
5. Selection tips and variants of interest
Tissue to suture: USP 5/0 gauge is a fine thread with high relative strength, indicated for approximation of soft tissues, subcutaneous planes, paediatric, cardiovascular and ophthalmological surgery. The HS16 reverse cutting needle is optimised to penetrate skin and firm tissues with controlled cutting; for lax or vascular tissues, consider the conical point profiles from the same PDO range.
Variants of the same family available at Cahnos:
| Reference | Description |
|---|---|
| AM412HS1650 | PDO ½ circle triangular HS16 mm, USP 5/0, violet, 75 cm (standard range) |
| AMP411HS1650 | PDO Prime ½ circle triangular HS16 mm, USP 5/0, violet, 45 cm |
| AM411HS1650 | PDO ½ circle triangular HS16 mm, USP 5/0, violet, 45 cm (standard range) |
| AMP411XDS1650 | PDO Prime ⅜ circle precision reverse cutting triangular XDS 16 mm, USP 5/0, violet, 45 cm |
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference and batch number for traceability in the operating theatre. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews