We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Suture PDO/PDS Prime 1/2 Circle Triangular Reverse Cutting Needle HS16 mm USP 5/0 Violet 75 cm – Box 12 units

Original price was: 55,30 €.Current price is: 43,50 €.

Absorbable monofilament suture of Polydioxanone (PDO/PDS) Prime with ½ circle needle with reverse cutting triangular body and point of 16 mm (HS16), USP 5/0 gauge and violet grooved thread of 75 cm. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75 % at 2 weeks and excellent knot security. Sterile by ethylene oxide, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in box of 12 units with B2B conditions for hospitals and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412HS1650

Description

1. Introduction

The Absorbable Monofilament Suture PREMISUT PDO/PDS Polydioxanone in its Prime version is the reference choice for professionals who need a long-lasting, fine thread with predictable handling in delicate tissues. This presentation mounts a ½ circle needle with reverse cutting triangular body and point of 16 mm (HS16 profile), USP 5/0 gauge and violet grooved thread of 75 cm: a balanced configuration for general, paediatric and ophthalmological surgery that combines penetration power in firm tissues with minimal tissue trauma.

It is supplied sterile, ready for single use, in a box of 12 units, in a B2B format aimed at hospital replenishment, purchasing centres and public tenders.

2. Technical Explanation

Polydioxanone (PDO) is a synthetic absorbable polyester, a polymer composed of poly(p-dioxanone), which is presented in a monofilament structure: this configuration reduces the sawing effect when passing through tissue, minimises bacterial adherence and offers excellent tensile strength and knot security. Its absorption occurs by hydrolysis over a range of 180 to 210 days, without depending on tissue enzymes, which guarantees predictable mass loss and minimal tissue reaction.

The ½ circle needle with reverse cutting triangular point combines the penetration of a cutting point with a triangular body that avoids tearing of adjacent tissue: it is the indicated choice for skin, fascia and tissues of a certain consistency. The violet grooved colour of the thread improves its visibility over the surgical field.

3. Technical Specifications

Parameter Specification
Thread material Polydioxanone (PDO/PDS), synthetic polymer of poly(p-dioxanone)
Structure Grooved monofilament
Suture type Long-term synthetic absorbable
Gauge / size USP 5/0
Thread length 75 cm (1 thread per unit)
Thread colour Fluted violet
Needle shape ½ circle (half circumference)
Tip type Triangular reverse cutting (reverse cutting), body and point
Needle size 16 mm (HS 16 Prime profile)
Swaged 1 needle per suture
Range / quality Prime (premium range)
Absorption By hydrolysis in 180-210 days
Tissue reaction Minimal
Sterilisation Ethylene oxide (EO), single-use, not re-sterilisable
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Commercial presentation Box of 12 units (individual sterile sachets)
Article reference P412HS1650
SKU Cahnos AMP412HS1650

Tensile strength retention profile:

Time Tensile strength retention
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %
Complete absorption 180-210 days by hydrolysis

The strength retention profile is maintained during the critical phase of healing of slow-healing tissues, which recommends its use in closures of fascia, aponeurosis and structures subjected to sustained tension.

4. Equivalences and Cross-References

Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures. Against the verified configuration of this datasheet (½ circle needle with reverse cutting triangular body and point of 16 mm, USP 5/0 gauge, violet thread of 75 cm) the homologous families of PDS® II and PDS Plus® (polydioxanone monofilament, violet, uncoated and with triclosan respectively) and MonoPlus® from B. Braun/Aesculap, as well as the Surgicryl PDO line from SMI have been compared.

In the PDS II range from Ethicon the available ½ circle triangular needles are 22 mm (OS-4) and 40/48 mm (CP/CPX), so there is no exact match of size (16 mm) and point for gauge 5/0; in B. Braun/Aesculap the same configuration requires code-by-code verification in their official catalogue. There is no equivalence table validated by the manufacturer; consult with the technical department before use in tenders. The guaranteed 1:1 interchangeability remains within the Prime range itself.

5. Selection tips and variants of interest

Tissue to suture: USP 5/0 gauge is a fine thread with high relative strength, indicated for approximation of soft tissues, subcutaneous planes, paediatric, cardiovascular and ophthalmological surgery. The HS16 reverse cutting needle is optimised to penetrate skin and firm tissues with controlled cutting; for lax or vascular tissues, consider the conical point profiles from the same PDO range.

Variants of the same family available at Cahnos:

Reference Description
AM412HS1650 PDO ½ circle triangular HS16 mm, USP 5/0, violet, 75 cm (standard range)
AMP411HS1650 PDO Prime ½ circle triangular HS16 mm, USP 5/0, violet, 45 cm
AM411HS1650 PDO ½ circle triangular HS16 mm, USP 5/0, violet, 45 cm (standard range)
AMP411XDS1650 PDO Prime ⅜ circle precision reverse cutting triangular XDS 16 mm, USP 5/0, violet, 45 cm

Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference and batch number for traceability in the operating theatre. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)

Structure

Grooved monofilament

Gauge

USP 5/0

Tip type

Triangular reverse cutting (reverse cutting), body and point

Needle size

16 mm (HS16)

Swaged

1 needle per suture

Absorption mechanism

Hydrolysis, 180-210 days

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Manufacturer reference

P412HS1650

Indications

General surgery, paediatric cardiovascular tissues, ophthalmology, ligatures

Medida de aguja

HS 16

Usp

5/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Suture PDO/PDS Prime 1/2 Circle Triangular Reverse Cutting Needle HS16 mm USP 5/0 Violet 75 cm – Box 12 units”

Your email address will not be published. Required fields are marked *