Description
1. Introduction
The absorbable monofilament Polydioxanone (PDO/PDS) suture from the Prime line is the reference choice in surgery when prolonged tissue support is required with fully predictable resorption and minimal tissue reaction. This presentation combines a 70 cm fluted violet thread with a 1/2 circle reverse cutting triangular point needle of 26 mm (HS26), designed to penetrate firm tissues with the least possible trauma.
Absorbable synthetic medical device, sterile and single-use, with excellent value for money for B2B supply to operating theatres, general surgery departments, ophthalmology units and hospital purchasing centres. Commercial presentation in a box of 12 units.
2. Technical explanation
Polydioxanone is an absorbable synthetic polyester that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics (180-210 days). Being a monofilament, the thread has no wicking effect or capillary edges: it reduces bacterial adherence, minimises the sawing effect on tissue and facilitates sliding, with a firm feel and excellent knot security.
The 1/2 circle needle (half circumference) with triangular reverse cutting body and point penetrates tissue with an edge that prevents tearing in fibrous walls, and its triangular body provides maximum stability in the needle holder. USP 1 (metric 4) gauge is ideal for planes with moderate-to-high tension. The set is indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Material | Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone) |
| Quality | Prime (premium range) |
| Gauge | USP 1 (metric 4) |
| Thread length | 70 cm |
| Thread colour | Violet grooved |
| Needle shape | ½ circle (half circumference) |
| Tip type | Triangular reverse cutting (triangular body and point, reverse cutting) |
| Needle size | HS26 – 26 mm |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 units · SKU AMP418HS2601 |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
Complete absorption by hydrolysis between 180 and 210 days. The prolonged strength retention profile makes it especially suitable for slow-healing tissues and structures under sustained tension (fascia, aponeurosis).
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for this reference; the following comparisons come from verification against the official catalogue and regulatory databases and are indicative, not interchangeable 1:1 without validation by the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson) | PDS II (Polydioxanone) – Triangular 1/2 circle needle, reverse cutting point, OS-4 needle, violet, 70 cm | W9286T | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same 1/2 circle curvature and triangular point family, 70 cm violet thread; the needle size differs (22 mm heavy versus 26 mm for this reference) and the gauge, which must be verified code by code. Verified in the Ethicon EMEA catalogue. |
| Ethicon (Johnson & Johnson) | PDS Plus (Polydioxanone with triclosan coating) – OS-4 needle, violet, 70 cm | PDP9286H | Comparable by category (not interchangeable 1:1) | Same PDO base and triangular 1/2 circle needle; it incorporates an antibacterial triclosan coating that this standard PDO Prime lacks. Verify gauge and needle size before substitution. |
As homologous market families to be verified in the technical data sheet before substitution: the MonoPlus line from B. Braun (polydioxanone monofilament) and the PDS II / PDS Plus ranges from Ethicon, which must be checked reference by reference (USP 1 gauge, 26 mm 1/2 circle needle, reverse cutting triangular point, 70 cm thread and colour).
5. Selection tips and variants of interest
USP 1 (metric 4) gauge is indicated for tissues with moderate-to-high tension: fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels. The 1/2 circle reverse cutting triangular needle (HS) is designed for fibrous and non-compliant tissues; if the tissue is very lax or delicate (vessels, parenchyma), consider the cylindrical variant with conical point (HR) or trocar point (HRT) from the same family. Our catalogue includes related PDO/PDS variants: AM418HS2601 (same HS26 USP 1 violet 70 cm configuration in standard quality), AM418HS2610 (1/2 circle triangular HS26, gauge 0, 70 cm), AM413HS4810 (1/2 circle triangular HS48, gauge 0, 90 cm) and AM418HRT2630 (1/2 circle cylindrical trocar point HRT26, 3/0, 70 cm). For hospital traceability orders and tenders, consult our technical department before formalising a brand substitution.