Description
1. Introduction
The absorbable monofilament Polydioxanone (PDO/PDS) suture is the reference technical solution when prolonged tissue support is required with fully predictable reabsorption and minimal tissue reaction. This presentation combines a 70 cm violet grooved thread in USP 0 (metric 3.5) gauge with a ½ circle triangular reverse cutting point needle of 26 mm (HS26), designed to penetrate firm tissues with the least possible trauma.
Synthetic absorbable medical device, sterile and single-use, with an excellent quality-performance ratio for B2B procurement of operating theatres, general surgery services, ophthalmology units, paediatric cardiovascular surgery and hospital purchasing centres. Commercial presentation in a box of 12 units, reference AM418HS2610.
2. Technical explanation
Polydioxanone is a synthetic absorbable polyester (polymer of poly(p-dioxanone)) that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees highly reproducible absorption kinetics. Being a monofilament, the thread has no wicking effect or capillary edges: it reduces bacterial adherence, minimises the sawing effect on tissue and facilitates sliding, with a firm feel and excellent knot security.
The ½ circle needle (half circumference curvature) with triangular body and reverse cutting point (reverse cutting) penetrates tissue with an edge that avoids tearing in fibrous walls, and its triangular body provides maximum stability in the needle holder. The USP 0 (metric 3.5) gauge is versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues, fascia closure and ligatures. The grooved violet colour improves thread visibility on the surgical field.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone) |
| Thread structure | Grooved monofilament |
| Gauge | USP 0 (metric 3.5) |
| Thread length | 70 cm |
| Thread colour | Fluted violet (high visibility) |
| Needle shape | ½ circle (half circumference) |
| Tip type | Triangular reverse cutting (reverse cutting), triangular body and point |
| Needle size | HS26 – 26 mm |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 units · Ref. AM418HS2610 |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained tension. It is supplied sterile, ready for use, in individual packaging.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). Based on the verified configuration of this data sheet (½ circle triangular reverse cutting needle of 26 mm, USP 0 gauge, 70 cm violet thread), the following commercial reference from another manufacturer has been cross-checked in primary sources:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone), CP-2 needle | Z970H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament violet material without coating, same USP 0 gauge, same ½ circle curvature and reverse cutting point family (CP-2) of 26 mm, 70 cm thread. Confirmed on the GUDID/FDA regulatory basis (ETHICON, LLC) and in authorised distributors. |
As homologous market families to be verified code by code before substitution: Ethicon’s PDS Plus line (same PDO base with antibacterial triclosan coating), B. Braun’s MonoPlus line (violet polydioxanone monofilament) and SMI’s Surgicryl PDO line, which must be checked in their official technical data sheet (USP 0 gauge, 26 mm ½ circle needle, reverse cutting triangular point, 70 cm thread and colour). There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
The USP 0 (metric 3.5) gauge is indicated for tissues with moderate tension: fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels. The ½ circle reverse cutting needle (HS) is designed for fibrous and non-compliant tissues; if the tissue is very lax or delicate (vessels, parenchyma), consider the cylindrical variant with conical point (HR) or trocar point (HRT) from the same family.
Within the Cahnos catalogue, the following related PDO/PDS variants are available: AMP418HS2610 (same HS26 configuration, USP 0, violet, 70 cm in Prime quality), AM418HS2620 (½ circle triangular HS26, USP 2/0 gauge, violet, 70 cm), AM418HS2601 (½ circle triangular HS26, USP 1 gauge, violet, 70 cm), AM418HRT2630 (½ circle cylindrical trocar point HRT26, USP 3/0, violet, 70 cm) and AM413HS4810 (½ circle triangular HS48, USP 0 gauge, violet, 90 cm). Always verify the USP gauge, size and needle geometry against your surgical protocol before substituting one reference for another. For special B2B conditions by volume, public tenders or batch traceability, contact our technical-commercial department.





Reviews