We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone PDO/PDS Suture · ½ Circle Triangular Reverse Cutting Needle HS26 (26 mm) · USP 0 Gauge (Metric 3.5) · Violet Thread 70 cm · Ref. AM418HS2610 · Box of 12 units

Original price was: 44,90 €.Current price is: 36,95 €.

Absorbable monofilament Polydioxanone (PDO/PDS) suture with ½ circle reverse cutting triangular point needle (reverse cutting) of 26 mm (HS26), USP 0 (metric 3.5) gauge and 70 cm violet grooved thread. Predictable absorption by hydrolysis in 180–210 days, with strength retention of 75% at 2 weeks, 60–70% at 4 and 45% at 8. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Ref. AM418HS2610, presentation in a box of 12 units under B2B conditions for hospitals and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM418HS2610

Description

1. Introduction

The absorbable monofilament Polydioxanone (PDO/PDS) suture is the reference technical solution when prolonged tissue support is required with fully predictable reabsorption and minimal tissue reaction. This presentation combines a 70 cm violet grooved thread in USP 0 (metric 3.5) gauge with a ½ circle triangular reverse cutting point needle of 26 mm (HS26), designed to penetrate firm tissues with the least possible trauma.

Synthetic absorbable medical device, sterile and single-use, with an excellent quality-performance ratio for B2B procurement of operating theatres, general surgery services, ophthalmology units, paediatric cardiovascular surgery and hospital purchasing centres. Commercial presentation in a box of 12 units, reference AM418HS2610.

2. Technical explanation

Polydioxanone is a synthetic absorbable polyester (polymer of poly(p-dioxanone)) that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees highly reproducible absorption kinetics. Being a monofilament, the thread has no wicking effect or capillary edges: it reduces bacterial adherence, minimises the sawing effect on tissue and facilitates sliding, with a firm feel and excellent knot security.

The ½ circle needle (half circumference curvature) with triangular body and reverse cutting point (reverse cutting) penetrates tissue with an edge that avoids tearing in fibrous walls, and its triangular body provides maximum stability in the needle holder. The USP 0 (metric 3.5) gauge is versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues, fascia closure and ligatures. The grooved violet colour improves thread visibility on the surgical field.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Material Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone)
Thread structure Grooved monofilament
Gauge USP 0 (metric 3.5)
Thread length 70 cm
Thread colour Fluted violet (high visibility)
Needle shape ½ circle (half circumference)
Tip type Triangular reverse cutting (reverse cutting), triangular body and point
Needle size HS26 – 26 mm
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units · Ref. AM418HS2610

3.2. Tensile strength retention profile

Period Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained tension. It is supplied sterile, ready for use, in individual packaging.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). Based on the verified configuration of this data sheet (½ circle triangular reverse cutting needle of 26 mm, USP 0 gauge, 70 cm violet thread), the following commercial reference from another manufacturer has been cross-checked in primary sources:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone), CP-2 needle Z970H Comparable by category (not interchangeable 1:1) Same PDO monofilament violet material without coating, same USP 0 gauge, same ½ circle curvature and reverse cutting point family (CP-2) of 26 mm, 70 cm thread. Confirmed on the GUDID/FDA regulatory basis (ETHICON, LLC) and in authorised distributors.

As homologous market families to be verified code by code before substitution: Ethicon’s PDS Plus line (same PDO base with antibacterial triclosan coating), B. Braun’s MonoPlus line (violet polydioxanone monofilament) and SMI’s Surgicryl PDO line, which must be checked in their official technical data sheet (USP 0 gauge, 26 mm ½ circle needle, reverse cutting triangular point, 70 cm thread and colour). There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

The USP 0 (metric 3.5) gauge is indicated for tissues with moderate tension: fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels. The ½ circle reverse cutting needle (HS) is designed for fibrous and non-compliant tissues; if the tissue is very lax or delicate (vessels, parenchyma), consider the cylindrical variant with conical point (HR) or trocar point (HRT) from the same family.

Within the Cahnos catalogue, the following related PDO/PDS variants are available: AMP418HS2610 (same HS26 configuration, USP 0, violet, 70 cm in Prime quality), AM418HS2620 (½ circle triangular HS26, USP 2/0 gauge, violet, 70 cm), AM418HS2601 (½ circle triangular HS26, USP 1 gauge, violet, 70 cm), AM418HRT2630 (½ circle cylindrical trocar point HRT26, USP 3/0, violet, 70 cm) and AM413HS4810 (½ circle triangular HS48, USP 0 gauge, violet, 90 cm). Always verify the USP gauge, size and needle geometry against your surgical protocol before substituting one reference for another. For special B2B conditions by volume, public tenders or batch traceability, contact our technical-commercial department.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone)

Gauge

USP 0 (metric 3.5)

Needle size

HS26 – 26 mm

Needle type

Half circle, triangular reverse cutting point (reverse cutting)

Thread colour

Violet grooved

Sterilisation

Ethylene oxide (single-use)

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues, ophthalmology

Medida de aguja

HS 26

Usp

0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Suture · ½ Circle Triangular Reverse Cutting Needle HS26 (26 mm) · USP 0 Gauge (Metric 3.5) · Violet Thread 70 cm · Ref. AM418HS2610 · Box of 12 units”

Your email address will not be published. Required fields are marked *