We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · USP 2/0 Violet 70 cm · Needle ½ Circle Triangular Reverse Cutting HS26 mm · Box 12 units

Original price was: 48,39 €.Current price is: 43,50 €.

Absorbable monofilament suture of medical-grade polydioxanone (PDO/PDS), Prime quality, with predictable absorption by hydrolysis in 180–210 days and excellent strength retention (75 % at 2 weeks). Presentation with a ½ circle reverse cutting needle with triangular point, 26 mm (HS26), USP size 2/0 (metric 3), violet thread, 70 cm. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Sterile by ethylene oxide, single-use. Box of 12 units with special B2B conditions for hospitals and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HS2620

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line is the technical reference choice when prolonged tissue support is needed with fully predictable resorption and minimal tissue reaction. This presentation combines a violet 70 cm thread in USP 2/0 gauge with a ½ circle needle, triangular reverse cutting point of 26 mm (HS26), designed to penetrate firm tissues with the least possible trauma.

Available in a box of 12 units, it is a cost-effective and reliable solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality consistency with CE certification.

2. Technical explanation of the product and procedure

Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillary edges, which reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilaments.

The ½ circle needle with triangular reverse cutting point penetrates tissue with an edge that avoids tearing in fibrous walls, and its triangular body provides maximum stability in the needle holder. The USP 2/0 gauge (metric 3) is versatile: suitable for subcutaneous tissue, superficial muscle planes and approximation of soft tissues. The set is indicated for tissue approximation, ligatures, general surgery, fascia closure, paediatric cardiovascular tissues and ophthalmology.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Monofilament
Gauge / size USP 2/0 (metric 3, approximate diameter 0.30 – 0.339 mm)
Thread colour Violet (high visibility)
Needle shape ½ circle (half circumference)
Tip type Reverse cutting triangular (reverse cutting)
Needle size HS 26 mm
Thread length 70 cm
Absorption mechanism Hydrolysis (180 – 210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units
Reference (SKU) AMP418HS2620

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60 – 70 %
8 weeks 45 %
Complete absorption 180 – 210 days by hydrolysis

This force retention profile is maintained during the critical healing phase of slow-healing tissues, which recommends its use in fascia closures, aponeuroses and structures under sustained tension. It is supplied sterile, ready for use, in individual packaging.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures. Based on the verified configuration of this data sheet (½ circle needle of 26 mm, USP 2/0 gauge, violet 70 cm thread), the following commercial references from other manufacturers have been cross-checked in primary sources:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® (polydioxanone) violet monofilament Z317H (confirmed: USP 2/0, 70 cm, violet, SH 26 mm ½ circle needle) Comparable by category (not interchangeable 1:1) Same PDO monofilament material, same USP 2/0 gauge, same thread length (70 cm) and same violet colour. Difference: SH needle with conical point (taper point) versus the triangular reverse cutting point (HS26) of this reference. Confirmed in official catalogues and authorised distributors.
B. Braun / Aesculap MonoPlus® (polydioxanone) uncoated monofilament, violet C0024086 (confirmed in official catalogue B. Braun: USP 2/0 / EP 3, 70 cm, violet, HR26S ½ circle needle) Comparable by category (not interchangeable 1:1) Same PDO monofilament material, same USP 2/0 gauge (EP 3), same thread length (70 cm) and same violet colour. Difference: HR26S needle with conical point versus the triangular reverse cutting point (HS26) of this reference. Confirmed in official catalogue B. Braun.

As homologous market families to be verified code by code before substitution: the PDS Plus® line from Ethicon (same PDO base with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun in reverse cutting needle configurations (HS26S) available from authorised distributors, the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked in their official technical data sheet (gauge, length, colour and needle geometry). There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. The needle shape is also decisive: the ½ circle triangular reverse cutting (HS) is designed for fibrous and somewhat firm tissues, while the conical point (SH/HR) is reserved for delicate tissues such as vessels.

Within the Cahnos catalogue, this reference (HS26, USP 2/0, 70 cm, Prime) has the following variants of the same PDO family:

  • AM418HS2620: same configuration (½ circle triangular HS26 mm, USP 2/0, violet, 70 cm) in normal quality.
  • AM418HS2610: ½ circle triangular HS26 mm, USP 0, violet, 70 cm (same needle and length, larger gauge for more tension).
  • AMP412HS3620: ½ circle triangular HS36 mm, USP 2/0, violet, 75 cm (longer needle for deeper fields).
  • AMP412DS2620.2: ⅜ circle triangular DS26 mm, USP 2/0, violet, 2 x 75 cm (double thread and smaller curvature).
  • AM41-2.7020: PDO/PDS without needle, USP 2/0, violet, 2 threads of 70 cm (for ligatures with own needle or thread passers).

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or public tenders, request confirmation of batch traceability and supply conditions from our technical-commercial department.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament

USP size

2/0 (metric 3)

Tip type

Triangular reverse cutting (reverse cutting)

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Use

Single-use, not re-sterilisable

Medida de aguja

HS 26

Usp

2/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · USP 2/0 Violet 70 cm · Needle ½ Circle Triangular Reverse Cutting HS26 mm · Box 12 units”

Your email address will not be published. Required fields are marked *