Description
1. Introduction
The class F1 stainless steel standard weight is the ideal metrological reference for the calibration and verification of precision balances and scales in laboratories, industry, pharmacy and quality control centres. Its high accuracy allows you to detect discrepancies in weighing equipment before they compromise the quality of results.
At Cahnos we supply it as an individual weight with case in the nominal value you need, from 1 g to 20 kg, with the option of an ENAC calibration certificate to ensure official traceability of your weighing process.
2. Technical explanation
Class F1 weights are manufactured from high-quality stainless steel, with a polished surface, low magnetic susceptibility and excellent corrosion resistance. These characteristics minimise moisture absorption and surface contamination that would alter their conventional mass value, ensuring excellent mass stability over time.
Each weight is adjusted within the maximum permissible errors set by the international recommendation OIML R111 for class F1, so that the actual mass value remains within very strict tolerances across its entire nominal range. Class F1 occupies the third step of precision on the OIML scale (behind E1 and E2) and is the recommended choice for precision balances with a readability of 0.1 g to 0.01 g, as well as for laboratories that must meet quality requirements such as ISO 9001, ISO 17025, GLP or GMP.
3. Technical Specifications
| Field | Detail |
|---|---|
| Description | Individual class F1 weight, in stainless steel. |
| Family | Standard weights — Class F1 |
| Typical use | Precision balances |
| Usual material | Stainless steel (low magnetic susceptibility) |
| Finish | Polished surface |
| Case | Yes |
| Reference standards | OIML R111 |
| Optional documentation | ENAC calibration certificate |
| Class | Description | Available nominal values |
|---|---|---|
| F1 | High precision | 1 mg – 10 kg (references available up to 20 kg) |
Maximum permissible tolerances class F1 (OIML R111)
| Nominal value | Maximum permissible error (±) |
|---|---|
| 1 g | ± 0.5 mg |
| 2 g | ± 0.6 mg |
| 5 g | ± 0.8 mg |
| 10 g | ± 1.0 mg |
| 20 g | ± 1.2 mg |
| 50 g | ± 1.6 mg |
| 100 g | ± 2.0 mg |
| 200 g | ± 2.5 mg |
| 500 g | ± 4.0 mg |
| 1 kg | ± 5.0 mg |
| 2 kg | ± 10 mg |
| 5 kg | ± 25 mg |
| 10 kg | ± 50 mg |
| 20 kg | ± 100 mg |
References and ordering information
| Capacity | Case | Description |
|---|---|---|
| 1 g | Yes | Individual weight |
| 2 g | Yes | Individual weight |
| 5 g | Yes | Individual weight |
| 10 g | Yes | Individual weight |
| 20 g | Yes | Individual weight |
| 50 g | Yes | Individual weight |
| 100 g | Yes | Individual weight |
| 200 g | Yes | Individual weight |
| 500 g | Yes | Individual weight |
| 1 kg | Yes | Individual weight |
| 2 kg | Yes | Individual weight |
| 5 kg | Yes | Individual weight |
| 10 kg | Yes | Individual weight |
| 20 kg | Yes | Individual weight |
Applications and typical uses
- High-precision standard weights, designed to ensure metrological traceability and reliable results in calibration and verification processes.
- Compliance with OIML R111 for classes M2, M1, F1 and E2.
- Calibration of precision balances and scales.
- Quality control in industry.
- Laboratories and metrology centres.
- Educational and research centres.
4. Equivalences and Cross-References
The OIML R111 class scale orders standard weights from highest to lowest precision: E1, E2, F1, F2, M1, M1-2, M2, M2-3 and M3. Class F1 offers tolerances approximately five times more permissive than class E2 and five times stricter than M1, which makes it the most commercially balanced option for general-purpose precision balances. It is directly comparable to the class F1 standard weight series of the main European and international manufacturers of weighing instruments (Kern, Sartorius, Ohaus, Adam Equipment, Radwag, PCE, Troemner and similar), as well as to the specifications of the ASTM E617 standard when the customer works with that standard.
Within the Cahnos catalogue you can cross-reference this item with the rest of the family according to your needs: the class E2 weight in stainless steel (PESA-E2INOX) for more demanding analytical balances, the F1 version in chrome-plated brass (PESA-F1LATON) as a more economical alternative, the class M1 in chrome-plated brass (PESA-M1LATON), the M1 weights in polished steel in a case and cast iron (PESA-M1HIERRO) for verification of industrial scales, and the class M2 in chrome-plated brass (PESA-M2LATON) for frequent industrial control.
5. Selection tips and variants of interest
- Select the nominal value according to the usual calibration points of your balance: it is recommended to verify at least with weights close to 10%, 50% and 100% of the equipment’s capacity.
- A precision balance with a readability of 0.1 g or 0.01 g is correctly calibrated with class F1 weights; for analytical balances of 0.1 mg or less, consider class E2 or E1.
- If your process requires audits or official traceability to national standards, request the weight with an ENAC calibration certificate: each piece is issued with its conventional mass value, expanded uncertainty (k=2) and corrections.
- Always handle the weight with gloves, forceps or a technical cloth, avoid manual contact and keep it in its case when not in use to preserve its precision class.
- For complete control, combine several individual weights of this same reference or complete your purchase with the precision balance suitable for your workload.





Reviews