Description
1. Commercial Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture from the Premisut range, reference 1L12HR3001, is the trusted solution for hospitals, private clinics, ophthalmology operating theatres and procurement groups seeking a high-performance synthetic absorbable thread with an excellent quality-price ratio. It features a ½ circle needle with cylindrical body and taperpoint tip of 30 mm (HR 30), USP size 1 and violet braided thread of 75 cm. Each unit is supplied sterile and ready to use, ideal for tissue approximation, ligatures and ophthalmic surgery, where precision, handling and fully predictable absorption during the first weeks of healing are required.
2. Technical explanation of the material and procedure
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented as a braided multifilament with a grooved finish. This structure provides great flexibility, low memory, smooth passage and a contained coefficient of friction that favours firm and secure knot tying. Absorption occurs by hydrolysis, independent of the patient’s enzymatic activity, over a predictable period of 56 to 72 days, with a constant and controlled loss of strength during the critical healing phase while the tissue regains its own strength.
The ½ circle needle with cylindrical body and taperpoint tip passes through tissue by separating the fibres without cutting them, minimising trauma to delicate structures; for this reason it is especially recommended in ophthalmic surgery, soft tissue approximation and ligatures. The violet colour ensures optimal visibility of the thread in the surgical field throughout the procedure. Sterile single-use product, with no possibility of resterilisation.
3. Technical Specifications
| Reference (SKU) | 1L12HR3001 |
| Brand / Quality | Premisut – standard quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Suture type | Synthetic absorbable multifilament |
| Thread structure | Braided and coated multifilament, grooved finish |
| Gauge | USP 1 (metric 4) |
| Thread length | 75 cm |
| Thread colour | Violet (colourless version available on request) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 30 mm (HR 30) |
| Mounting | Needle threaded with suture |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Absorption and tensile strength retention profile:
| Period | Retention of initial tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56-72 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and knot security, with a predictable absorption rate.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture belongs to the family of synthetic braided absorbable sutures with medium absorption, clinically equivalent in composition, absorption profile and mechanical behaviour to the reference lines of the international market:
| Manufacturer / commercial house | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
Within the Cahnos catalogue, this reference shares the family with the PGLA line with ½ circle cylindrical needle: its direct equivalent in the same HR 30 mm USP 1 configuration corresponds to the Heavy version 1L12HR3001H, the Prime quality P1L12HR3001 and the Prime Heavy P1L12HR3001H. The equivalences indicated are for guidance only; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the size according to the anatomical area. USP size 1 provides high initial strength and is suitable for tissues under tension, aponeuroses and tension closures; sizes 0 and 2/0 are intended for more delicate planes. The taperpoint tip is ideal for soft tissues and delicate structures such as ocular ones; for fibrous tissues or the sclera, trocar-type penetration tips are recommended.
Variants of interest in the same PGLA family: 1L12HR3010 (USP size 0), 1L12HR3010H (Heavy USP 0), 1L12HR3020 (size 2/0), 1L12HR3030 (size 3/0), 1L12HR4001H (Heavy USP 1, HR 40 mm needle with larger radius), 1L18JR3001 (JR 30 mm hook needle), P1L12RHRP3001 (Ultra Plus trocar tip for fibrous tissues) and AM112HR3001 (PGA equivalent). All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to guarantee continuous supply for your centre.
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial brands, contact our technical-commercial team at Cahnos.