Description
1. Commercial Introduction
At Cahnos we make available to operating theatres, general surgery departments, gynaecology units, urology and purchasing centres this absorbable monofilament suture of poliglecaprone 25 (PGCL / caprolactone), factory reference 318HR2610 (SKU AM318HR2610). This presentation combines a ½ circle needle with cylindrical body and Taperpoint conical point of 26 mm (HR26 profile), USP 0 gauge and 70 cm violet thread.
It is a medium-absorption thread (90–120 days), with exceptional handling and high knot security, designed for the professional who needs reliable wound support during the first weeks with a very competitive quality-performance ratio for hospital procurement. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.
2. Technical explanation
Poliglecaprone 25 (PGCL) is a synthetic absorbable copolymer of glycolide and ε-caprolactone that degrades by hydrolysis, i.e. by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 90 to 120 days and independent of the patient’s enzymatic activity. Being a monofilament, the strand has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, while maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.
The ½ circle needle with cylindrical body and Taperpoint conical point passes through soft tissue by separating the fibres without cutting effect, which makes it especially atraumatic in delicate structures, subcutaneous tissue and approximation of soft tissues. The violet colour of the thread guarantees optimal visibility on the surgical field even with difficult lighting or bleeding. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AM318HR2610
| Parameter | Specification |
|---|---|
| SKU Cahnos | AM318HR2610 |
| Factory reference | 318HR2610 (PREMISUT POLIGLECAPRONE 25 CAPROLACTONE PGCL) |
| Material | Polyglecaprone 25 (PGCL), copolymer of glycolide and ε-caprolactone |
| Thread structure | Synthetic absorbable monofilament |
| Gauge | USP 0 (metric 3.5); conforming to USP Pharmacopoeia / European Pharmacopoeia |
| Thread colour | Violet (high visibility in the field) |
| Needle shape | ½ circle (half circumference) |
| Needle body and point | Cylindrical body, Taperpoint conical tip, atraumatic |
| Needle size | HR26 – 26 mm |
| Thread length | 70 cm (1 thread · 1 needle per unit) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90–120 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Soft tissue approximation and general ligatures |
| Quality | Normal |
| Presentation | Box of 12 sterile units · minimum order 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 1 week | 60% of initial tensile strength |
| 2 weeks | 30% of initial tensile strength |
| Complete absorption | 90–120 days, by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
4. Equivalences and Cross-References
Poliglecaprone 25 monofilament is one of the most well-established synthetic absorbable suture materials of medium absorption on the market, with the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech) being the clinical reference in the category. For the USP 0 configuration, ½ circle conical-point needle of 26 mm and 70 cm violet strand, the following correspondence has been verified against the manufacturer’s official catalogue, regulatory database (GUDID/FDA) and authorised distribution sources, with the caveat that the commercial assembly of each house presents differences in needle finish or presentation, so they are not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® – poliglecaprone 25 monofilament, violet, USP 0, 70 cm, SH needle of 26 mm, ½ circle, taper point | Y318H | Comparable by category (not interchangeable 1:1) | Confirmed in GUDID and official Ethicon catalogue: material (poliglecaprone 25), USP 0 gauge, violet colour, monofilament structure, ½ circle geometry, 26 mm needle size and conical point family all match. The needle code (SH vs HR26) and the presentation (box of 36 units vs 12) differ. Validate in the technical data sheet/IFU before substituting in a tender. |
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® Plus Antibacterial – poliglecaprone 25 with triclosan, violet, USP 0, 70 cm, SH needle of 26 mm | MCP318H | Comparable by category (not interchangeable 1:1) | Same USP 0 · SH 26 mm · violet configuration, with added antibacterial triclosan. The antibacterial load represents a relevant functional difference compared with this uncoated reference. Validate in the technical data sheet/IFU before substituting. |
| B. Braun (Aesculap) | Monosyn – absorbable monofilament of glyconate, violet, half circle conical needle | C20 series (glyconate) | Comparable by category (not interchangeable 1:1) | Same general clinical indication (medium absorption, monofilament, conical point), but different composition (glyconate vs poliglecaprone 25) and its own needle nomenclature. Check gauge, needle size and strength retention in the official data sheet before any substitution. |
There is no manufacturer-validated equivalence table that cross-references this specific configuration (PGCL monofilament, 26 mm HR26 conical-point needle, USP 0 gauge, 70 cm violet thread, ref. 318HR2610) with references from other houses in exact assembly; consult the technical department before using in a tender or direct substitution. The factory reference PREMISUT for this article does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in tender documents. Before validating any candidate from another brand, check one by one: exact material (poliglecaprone 25 vs PGA, PDO or glyconate), USP gauge, needle geometry and size, curvature, number and length of strands, colour, strength retention and the current CE/MDR classification. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) with a 26 mm needle is suitable for approximating medium-thickness tissues, muscular wall, peritoneum, subcutaneous tissue and vascular ligatures where resistance is required during the first 2–3 weeks of healing; the cylindrical body with Taperpoint conical point is indicated for soft tissues and vascular structures, minimising tissue damage. If greater penetration in firm or slightly fibrous tissues is needed, consider the trocar-point (Tapercut) versions of the same family (HRT series), and if a needle with a larger radius is preferred, the HR30 or HR36 versions in the catalogue.
| Reference (SKU) | Variant of interest |
|---|---|
| AMP318HR2610 | Same HR26 configuration, USP 0, violet, 70 cm in Prime quality (premium range) |
| AMP318HRP2610 | PGCL Prime, HRP 26 mm needle, Ultra Plus taper point, USP 0, violet, 70 cm (higher performance point) |
| AM318HRT3610 | PGCL, HRT 36 mm needle, trocar point (Tapercut), USP 0, violet, 70 cm (for firmer tissues) |
| AM318HR2630-2 | PGCL, double HR26 taper-point needle, USP 3/0, violet, 70 cm (continuous suture) |
| AM318HR2640 | PGCL, HR26 needle, taper point, USP 4/0, violet, 70 cm (more superficial plane) |
| AM312HR3610 / AM313HR3610 | PGCL, HR36 conical-point needle, USP 0, violet, 75 cm / 90 cm (longer thread) |
If the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA (60–90 days) or polyglactin 910 (56–72 days). As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure, and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or validation of equivalences with other commercial houses, contact the technical-commercial team at Cahnos.





Reviews