We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Veterinary SpO₂ Pulse Oximeter Catheter for Veterinary Electronic Sphygmomanometer — Ref. 80557 (Compatible with 80550, Requires Cable 80558)

27,55 €

Reusable veterinary SpO₂ pulse oximeter catheter designed as an optional accessory for the veterinary electronic sphygmomanometer (code 80550). It allows the cardiovascular assessment of the animal patient to be completed with non-invasive measurement of blood oxygen saturation and pulse rate, with a SpO₂ range of 0–100 % (resolution 1 %) and accuracy of ± 2 % in the range of 70–100 %. Pulse rate is measured between 30 and 250 lpm with an accuracy of ± 2 lpm or ± 2 % (whichever is greater). It requires the connection cable 80558 for use with the monitor. Manufacturer’s reference: 80557 (.). For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM80557

You will also find it in

Description

1. Introduction

The veterinary SpO₂ catheter (ref. 80557) is the complementary accessory of the veterinary electronic sphygmomanometer (code 80550), designed for the professional who wishes to expand the diagnostic capabilities of their equipment. With this optional catheter you will be able to obtain, in the same examination, the blood oxygen saturation (SpO₂) and the pulse rate of the animal patient, two essential parameters to assess their haemodynamic status quickly and non-invasively.

It is a reusable component that integrates with the veterinary electronic sphygmomanometer via the connection cable 80558. A simple, reliable and highly useful accessory in veterinary clinics and practices.

2. Technical explanation

Pulse oximetry is a non-invasive optical technique that estimates the functional oxygen saturation of arterial haemoglobin (SpO₂). The catheter emits light at two wavelengths through the tissue (usually the sensor application area) and a photodetector records the differential absorption according to the degree of blood oxygenation. The pulsatile component of the signal, generated by the arterial beat, allows the percentage of saturated haemoglobin and the pulse rate (PR) to be calculated simultaneously.

In the veterinary field, this measurement is of great value in monitoring patients during anaesthesia, in emergencies, in the follow-up of respiratory or cardiovascular pathologies and in perioperative control. When coupled to the veterinary electronic sphygmomanometer (code 80550), the device combines blood pressure measurement with oxygen saturation and pulse rate, offering the veterinarian a more complete cardiovascular assessment in a single device.

3. Technical Specifications

The functional specifications of the catheter are as follows:

Parameter Specification
SpO₂ range 0–100 % (resolution 1 %)
SpO₂ accuracy 70 %–100 %: ± 2 %
Pulse rate range (PR) 30 lpm–250 lpm (resolution 1 lpm)
Pulse rate accuracy (PR) ± 2 lpm or ± 2 % (whichever is greater)

Product data

Manufacturer GIMA
Manufacturer reference 80557
Compatibility Veterinary electronic sphygmomanometer (code 80550); requires connection cable 80558
Sales unit 1 pc
Device type No medical device
EAN 6945040109884

4. Equivalences and Cross-References

This catheter is an accessory specific to the veterinary measurement system and there is no official equivalence table published by the manufacturer that cross-references it interchangeably with sensors from other brands. The related references within the same family are:

Reference Description Related items
80550 Veterinary electronic sphygmomanometer Base unit with which the catheter is used
80557 Veterinary SpO₂ catheter (this product) Optional accessory for device 80550
80558 Connection cable for the SpO₂ catheter Cable required for the catheter to work with the device

Before placing the order, confirm with our technical-commercial department the exact compatibility with your sphygmomanometer unit and the need for cable 80558 if you do not have it.

5. Selection tips and variants of interest

Check your device’s configuration: if you already have the veterinary electronic sphygmomanometer (80550) but it does not include the pulse oximeter catheter, this is the reference you should request. Remember that the catheter requires the connection cable 80558 to operate.

Intended use: the catheter is intended for measuring oxygen saturation and pulse rate in animal patients together with device 80550. As it is a reusable accessory, clean the sensor surface between patients following the hygiene recommendations for veterinary diagnostic material.

Application in practice: it is especially useful in the monitoring of anaesthetised patients, in emergencies and in the follow-up of respiratory and cardiovascular processes, complementing the blood pressure measurement of the sphygmomanometer.

To complete the equipment of your veterinary diagnostic area, consult Cahnos for the veterinary electronic sphygmomanometer (80550) and the rest of the available range of accessories. For large orders you can request a quote.

Additional information

Device type

No medical device

Manufacturer

GIMA S.p.A.

Manufacturer reference

80557

Compatibility

Veterinary electronic sphygmomanometer (code 80550); requires connection cable 80558

SpO2 range

0–100 % (resolution 1 %)

Spo2 accuracy

± 2 % in range 70–100 %

Pulse rate range

30–250 lpm (resolution 1 lpm)

Pulse rate accuracy

± 2 lpm or ± 2 % (whichever is greater)

Use

Reusable veterinary pulse oximetry accessory

EAN

6945040109884

Presentacion

Unit

Tipo dispositivo

Medical device, Non-medical

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 CertificatesDispositivo non medico PDF

Reviews

There are no reviews yet.

Be the first to review “Veterinary SpO₂ Pulse Oximeter Catheter for Veterinary Electronic Sphygmomanometer — Ref. 80557 (Compatible with 80550, Requires Cable 80558)”

Your email address will not be published. Required fields are marked *