Description
1. Commercial Introduction
The veterinary SpO2 catheter (ref. 80712) is the manufacturer’s official replacement for the veterinary pulse oximeter Ref. 80710. Designed to ensure continuity of oxygen saturation monitoring in the clinic, this catheter allows you to replace the element that has the most direct contact with the animal patient and, therefore, suffers the greatest wear from daily use.
As an original manufacturer’s replacement, it maintains full connection and performance compatibility with the base unit, extending the life of the pulse oximeter without the need to purchase a new device. It is the practical and economical solution for veterinary clinics, animal hospitals and professionals dedicated to the diagnosis and monitoring of the animal patient.
2. Technical explanation of the equipment and procedure
Pulse oximetry is a non-invasive technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry. The SpO2 catheter emits light at two wavelengths (red and infrared) through the animal’s vascular bed, usually in areas of thin skin or mucous membranes such as the tongue, pinna, lips or perineal area depending on the species, and a photodetector on the opposite side quantifies the light absorbed by the tissues.
The pulsatile component of the signal, generated by the animal’s arterial beat, allows the percentage of saturated haemoglobin and heart rate to be calculated, data essential in anaesthetic control, emergency management, perioperative monitoring and follow-up of patients with respiratory or cardiovascular conditions. The 80712 catheter acts as the sensor element that attaches to the head of the pulse oximeter Ref. 80710 and transmits the signal to the device for processing and display.
As a replacement component, its correct placement on the chosen measurement point of the animal is key to obtaining stable readings: a firm contact must be ensured, without excessive pressure, in an area with good perfusion and free of hair or dirt that interferes with the optical signal.
3. Technical Specifications
Product data according to the manufacturer’s catalogue:
| Parameter | Detail |
|---|---|
| Product | Veterinary SpO2 catheter – replacement for pulse oximeter 80710 |
| Manufacturer reference | 80712 |
| Manufacturer | GIMA |
| Compatible equipment | Veterinary pulse oximeter Ref. 80710 |
| Sales unit | 1 pc |
| Device type | No medical device |
| EAN | 8023279807127 |
Table of available references:
| Item | Reference |
|---|---|
| SKU Cahnos | GM80712 |
| Manufacturer reference | 80712 |
| Base unit to which the replacement corresponds | 80710 |
| Presentation | Unit (1 pc) |
4. Equivalences and Cross-References
The 80712 catheter is the manufacturer’s official replacement for the veterinary pulse oximeter 80710, so its compatibility with that device is guaranteed. There is no manufacturer-validated equivalence table cross-referencing this reference with catheters from other manufacturers or other models: as it is a specific spare part, any substitution should be verified in advance with the technical department, confirming connector type, cable length and compatibility with the head of the pulse oximeter 80710 before use.
In the Cahnos catalogue, this replacement is complemented by the veterinary pulse oximeter Ref. 80710, for which it is intended, as well as the rest of the range of monitoring and diagnostic accessories available on request and quote.
5. Selection tips and variants of interest
Always verify the model of your device before requesting the replacement: the 80712 catheter is specifically designed for the veterinary pulse oximeter Ref. 80710. Indicate the reference and model of the device in your order to confirm exact compatibility.
To maintain the reliability of readings, periodically check the condition of the cable, connector and sensor element: a damaged, worn or connector-affected catheter can cause unstable signals or measurement errors. Keep a spare catheter in stock to avoid interruptions in service.
Store the catheter in a clean, dry place protected from direct sunlight, and clean the sensor element according to the manufacturer’s instructions between patients to avoid cross-contamination. For multiple consultation rooms, supply contracts or volume needs, contact our technical-commercial team to formalise a quote.