VET · Standard hypodermic needle 19G (1.1 x 38 mm) sterile – Triple bevel, cream colour (Ref. 23751) | Box of 100 units

3,80 €

Standard 19G hypodermic needle (1.1 x 38 mm), sterile and single-use, manufactured from AISI 304 stainless steel with a triple bevel grind that enables smooth penetration and minimises tissue trauma, achieving the most painless injection possible. Completely non-toxic and apyrogenic, each component receives a specific treatment aimed at patient comfort. Hub with reference colour cream for immediate gauge identification. Presentation in a box of 100 units, individually blister-packed, with multi-language box and instructions (GB, IT, ES, PT). Class IIa sterile medical device, ideal for hospitals, clinics, health centres and home care. For large orders, you can request a quote: consult our sales team.

Sales unit: caja de 100
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
VET-GM23751

You will also find it in

Description

1. Introduction

The standard 19G hypodermic needle (1.1 x 38 mm) is the trusted solution for hospitals, clinics, health centres and home care services that require reliable, comfortable and safe injection supplies. Its triple bevel sharpening minimises tissue trauma during penetration, while the specific treatment of each component of the set is designed to achieve the most painless injection possible for the patient. It is supplied in a box of 100 units, individually packaged in blister packs, with a box and instructions in several languages, including Spanish.

2. Technical explanation of the device

This hypodermic needle is manufactured with a cannula of stainless steel AISI 304, a completely non-toxic and apyrogenic material, suitable for contact with drugs and biological fluids. The triple bevel allows a smoother and more controlled penetration, reducing puncture force and tissue damage, which helps minimise the discomfort perceived by the patient during parenteral administration.

The 19G gauge corresponds to an outer diameter of 1.1 mm with a cannula length of 38 mm, and incorporates the reference colour cream on the hub, enabling immediate and unambiguous identification of the needle diameter during medication preparation. It is a sterile, single-use medical device, supplied in a box of 100 pieces with individual blister packaging that ensures sterility is maintained until the moment of use.

3. Technical Specifications

The technical features of the product are listed in the following table:

Characteristic Specification
Manufacturer GIMA
Manufacturer reference 23751 (SKU Cahnos: GM23751)
Gauge 19G (1.1 mm outer diameter)
Needle size 19G – 1.1 x 38 mm
Reference colour Cream
Cannula material Stainless steel AISI 304
Tip type Triple bevel (minimal trauma during penetration)
Sterility Sterile, single-use
Presentation Individual blister packaging
Sales unit Box of 100 units
Box and instructions GB, IT, ES, PT

Product data

Sales unit box of 100 pcs
Device type Medical device
Device class II A
CND A0101010102
EAN 8032764151942

4. Equivalences and Cross-References

Within the same family, the sterile standard hypodermic needles are available in gauges 18G to 25G (refs. GM23750 to GM23760), as a complete supply range when a safety mechanism is not required. On the market, 19G x 1 1/2″ (1.1 x 38-40 mm) hypodermic needles with cream colour code ISO 6009 from other manufacturers are classified as category-comparable (not 1:1 interchangeable without prior validation, since bevel design differs):

Manufacturer / Brand Family / Model Code / SKU Equivalence level
Terumo Agani™ 19G x 1″ (0.9… 1.1 x 25 mm) AN*1925R1 Comparable by category
Nipro Hypodermic needle 19G x 1 1/2″ (1.1 x 40 mm) HN-1938-ET Comparable by category
B. Braun Sterican 19G x 1 1/2″ (1.10 x 40 mm), colour cream Verify reference according to length Comparable by category

There is no manufacturer-validated equivalence table for this reference. Before any substitution, check the gauge, cannula length, material, bevel type and ISO conformity on the official technical data sheet.

5. Selection tips and variants of interest

The 19G gauge (1.1 mm) is a wide gauge option, ideal for high flows and administration of denser liquids or larger volumes, commonly used for withdrawing drugs from large-volume vials and in procedures requiring a generous flow rate with a well-tolerated puncture.

For other requirements, consider the full range of standard hypodermic needles (refs. GM23750 to GM23760), covering gauges from 18G to 25G: 18G and 19G are ideal for high flows and denser liquids, 21G is the versatile general-purpose option, and 23G and 25G are suitable for finer access and less discomfort. If your protocol requires protection against needlestick injuries, refer to the safety needle range (refs. GM23790, GM23791, GM23793 and GM23794).

Always check the integrity of the sterile blister before each use, do not reuse the needle, and after puncture dispose of it in an approved sharps container. For large orders, you can request a quote: ask our sales team for your offer.

Additional information

Manufacturer reference

23751

Gauge

19G (1.1 mm outer diameter)

Reference colour

Cream

Cannula material

Stainless steel AISI 304

Tip type

Triple bevel

Sterility

Sterile, single-use

Presentation

Box of 100 units, individually blister-packed

CND code

A0101010102

EAN

8032764151942

Languages for box and instructions

GB, IT, ES, PT

Presentacion

Box of 100

Tipo dispositivo

Medical device

Clase sanitaria

II a

Medida de aguja

1.1 × 38 mm