Description
1. Introduction
The Spinocan® range from B. Braun is a well-established reference in anaesthesiology and operating theatre services for access to the subarachnoid space using a Quincke cutting-bevel needle. Designed for spinal (intrathecal) anaesthesia and diagnostic lumbar puncture, it combines a sharp bevel that reduces penetration force and allows the characteristic dural ‘click’ to be felt, with a transparent hub with prism that instantly confirms cerebrospinal fluid (CSF) reflux before injection. Available in gauges from 22G to 29G, it is supplied in a box of 25 units in individual sterile packaging, covering the needs of hospitals, clinics and diagnostic centres.
2. Technical explanation of the procedure
Subarachnoid or spinal anaesthesia involves the administration of a local anaesthetic into the cerebrospinal fluid of the subarachnoid space, achieving a rapid, deep and reliable sensory and motor block, indicated for abdominal, urological, trauma, obstetric and lower limb surgery. The Quincke bevel tip, with its cutting geometry, creates a clean and controlled incision in the dura mater, facilitating entry through the ligamentous planes and precise orientation of the bevel opening throughout the puncture. The colour-coded obturator stylet maintains lumen patency and prevents tissue entry, while the hub with glass prism shines silver before reflux and becomes transparent as CSF passes through, confirming correct cannulation before injection. It is a sterile, single-use product, ensuring maximum protection against cross-infection.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Needle type | Spinal bevel needle (Quincke tip) |
| Available sizes | 22G to 29G |
| Outer diameter (e.g. 27G) | 0.40–0.42 mm |
| Common lengths | 35 / 50 / 88 / 103 / 120 mm depending on gauge |
| Tip type | Quincke bevel (sharp cutting) |
| Material | Medical-grade stainless steel cannula; stainless steel stylet |
| Hub | Transparent with prism that reflects CSF outflow |
| Mandrel | Colour-coded |
| Connection | Standard connector (Luer); NRFit® version available in the range |
| Application | Spinal anaesthesia and diagnostic lumbar puncture |
| Sterility | Sterile, single-use, individually packaged |
| Presentation | Box of 25 units |
Official Spinocan® references (B. Braun pattern, authorised distribution):
| Reference | Gauge | Size | Identification colour |
|---|---|---|---|
| 4501390 | 18G | 88 mm (3 1/2″) | Pink |
| 4501195 | 19G | 88 mm (3 1/2″) | Ivory |
| 4505000 | 20G | 25 mm (1″) | Yellow |
| 4503902 | 27G | 88 mm (3 1/2″) | — |
The Spinocan® family covers the full range from 22G to 29G; the remaining codes in the intermediate range are pending confirmation with the supplier depending on order requirements.
4. Equivalences and Cross-References
B. Braun does not publish an official cross-reference table for the Spinocan® range; equivalences between brands must be verified field by field before use in tenders. By tip family (Quincke cutting bevel, 27G gauge), the following references from another manufacturer are comparable by category (not interchangeable 1:1):
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Dahlhausen | Quincke bevel spinal needle, 27G × 3.5″ / 89 mm | 76.111.27.035 | Comparable by category (not interchangeable 1:1) | Same cutting Quincke tip family and 27G gauge; very similar length (89 mm vs 88 mm); connector and hub according to manufacturer |
| Dahlhausen | Quincke bevel spinal needle, 27G × 4.72″ / 120 mm | 76.111.27.120 | Comparable by category (not interchangeable 1:1) | Same Quincke tip family and 27G gauge; longer length (120 mm vs 88 mm), suitable for longer insertion path |
Technical warnings: the Quincke cutting tip is not equivalent to the atraumatic pencil-point tip (Pencan®, Whitacre, Sprotte): the incidence of post-dural puncture headache is different and they must not be substituted for each other without clinical evaluation. The BD Quincke 27G needle of 0.4 × 90 mm is comparable by category, but its specific code is pending confirmation with the manufacturer before citing it. Always verify before substitution: gauge, length, tip type, presence of introducer, connector (Luer vs. NRFit®, ISO 80369-6) and sterility of the actual product. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The 27G × 88 mm gauge (ref. 4503902) is the most requested standard variant for lumbar approaches in adults of medium build, prioritising minimal dural trauma within the fine range. If you require higher injection flow and rigidity, consider intermediate gauges (25G, 24G, 23G or 22G); if you work with special populations, consult the short and long lengths in the range. To minimise the risk of post-dural puncture headache in outpatients or those with early discharge, the service may consider the atraumatic pencil-point tip family (Pencan®), available in the Cahnos catalogue with and without introducer. Verify the integrity of the sterile packaging before each use and dispose of the needle after a single puncture in an approved container for sharps. For volume orders, supply contracts or tenders, contact the technical-commercial team at Cahnos.












Reviews
There are no reviews yet.