Description
1. Commercial Introduction
The sterile latex superficial cover for ultrasound probe Ultra Cover™ (Ref. 86667) is the single-use barrier consumable that your radiology, operating theatre, gynaecology or general medicine department needs to maintain hygiene, safety and transducer integrity in every examination. Made of high-quality latex, it provides great strength and elasticity, adapting exactly to the probe geometry without folds or air bubbles.
With dimensions of 6 × 30 cm and including 1 adhesive fixation strip for firm and stable hold throughout the procedure, it is supplied in flat format in boxes of 10 units, ideal for maintaining stock in the operating theatre, diagnostic imaging departments and high-volume ultrasound clinics.
2. Technical Explanation
In superficial ultrasound imaging, the ultrasound transducer slides over the patient’s skin using coupling gel. Placing a disposable cover between the probe and the medium prevents direct contact and significantly reduces the risk of cross-contamination between patients, while protecting the transducer head and extending the service life of the diagnostic equipment.
The high-quality latex of this cover provides superior elasticity and strength, achieving a firm, wrinkle-free fit that does not interfere with acoustic transmission or diagnostic image quality. Its sterile condition makes it especially suitable for procedures with asepsis requirements, such as guided biopsies, drainages, fine-needle aspiration or examinations in a surgical setting. The adhesive fixation strip ensures the cover stays in place throughout the procedure. It is a single-use product: do not reuse or re-sterilise.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 86667 |
| Product type | Disposable protective cover for superficial ultrasound probe |
| Material | High-quality natural latex, great resistance and elasticity |
| Measurements | 6 × 30 cm (width × length) |
| Sterility | Sterile |
| Fixation system | 1 adhesive fixation strip for secure hold |
| Format | Flat, easy to dispense and apply directly |
| Compatibility | Superficial ultrasound probes (linear and convex) from the leading brands on the market |
| Use | Single-use, disposable; do not reuse or re-sterilise |
| Commercial presentation | Box of 10 units (price per box) |
| Use environment | Operating theatre, guided invasive procedures and clinical ultrasound imaging |
| Family | Ultra Cover™ Sterile Latex Superficial |
Advantages of the material:
| Property | Benefit |
|---|---|
| High elasticity | Exact fit to the transducer head without folds |
| Strength and durability | Lower risk of breakage during examination |
| Effective barrier | Protection against cross-contamination |
| Acoustic conductivity | Does not interfere with the quality of the ultrasound image |
| Adhesive fixation | Stability of the cover throughout the procedure |
| Rapid placement | Time optimisation in operating theatre and consultation |
4. Equivalences and Cross-References
This cover belongs to the Ultra Cover™ sterile latex superficial family from Cahnos. Variants in the same sterile range with 1 adhesive fixation strip include references 86694 (4 × 30 cm), 86675 (5 × 30 cm) and 86633 (8 × 30 cm), all in boxes of 10 units.
For routine screening examinations without sterility requirements, the non-sterile version is available in the same family, such as references 86684 (4 × 30 cm) or 86653 (6 × 30 cm) in boxes of 100 units, and 650249 (3 × 30 cm). If your facility treats patients or professionals with latex allergy or sensitivity, the equivalent latex-free alternative is the Ultra Cover™ PIP family in synthetic polyisoprene: 88667PIP (6 × 30 cm sterile with adhesive strip, box of 10 units) and 88694PIP (4 × 30 cm sterile with adhesive strip, box of 10 units).
At market level, this cover acts as a functional equivalent of the superficial protectors distributed by manufacturers such as Dahlhausen (refs. 42.200.26.301, 26 × 300 mm, and 42.200.30.201, 30 × 200 mm), as well as the PULL UP™ type ranges (refs. 1-519-2524 and 1-519-2548) and the Eclipse covers from Parker (ref. E38-03), interchangeable for transducer protection barrier purposes in superficial ultrasound.
5. Selection tips and variants of interest
To choose the right cover, you must verify two parameters: the width and working length of your superficial transducer. The 6 × 30 cm size of this reference is ideal for linear and convex probes with a large contact surface, common in abdominal, musculoskeletal, soft tissue ultrasound and in guided examinations in the operating theatre. If your probe head has a smaller footprint, consider the variants 86675 (5 × 30 cm) or 86694 (4 × 30 cm); if larger, the 86633 (8 × 30 cm).
- Patients or professionals with latex allergy: always choose latex-free polyisoprene, polyurethane or polyethylene, such as the PIP references from the Ultra Cover™ range (88667PIP or 88694PIP).
- Procedures with strict asepsis (guided biopsies, drainages or surgery): keep the sterile versions of the range, such as this 86667.
- High volume of routine examinations: the non-sterile versions in boxes of 100 units (86684 or 86653) reduce the cost per unit and stock replenishments.
- Storage: keep the product in a dry, cool place protected from sunlight.
If you have any questions about the most suitable reference for your probe model, consult our technical-commercial team at Cahnos to confirm exact compatibility and evaluate special B2B conditions for hospitals, clinics and purchasing groups.





Reviews
There are no reviews yet.