Description
1. Commercial Introduction
The sterile superficial cover for ultrasound scanner catheter in latex-free polyisoprene (Ref. 88633PIP) is the single-use barrier consumable that your diagnostic imaging, gynaecology, obstetrics or general medicine service needs to maintain the hygiene and functionality of its equipment, also in centres that care for patients or professionals with allergy or sensitivity to latex. Made of synthetic polyisoprene —the synthetic latex—, it reproduces the elasticity, feel and strength of natural latex without the proteins responsible for allergic reactions.
Its fixation adhesive strip ensures that the cover stays in place throughout the examination, while the flat format and individual sterile packaging facilitate a quick, hygienic and trouble-free application in practices, hospitals and diagnostic centres.
2. Technical explanation of the procedure
During superficial ultrasound imaging, the ultrasound transducer slides directly over the patient’s skin using coupling gel. Interposing a disposable and sterile barrier between the catheter and the patient avoids direct contact, reduces the risk of cross-contamination between patients and protects the transducer head against gel residues and mechanical damage, prolonging the service life of the diagnostic equipment.
Polyisoprene provides elasticity comparable to that of natural latex with great adaptability to the transducer geometry. The result is a firm fit, without folds or bubbles, which does not interfere with acoustic transmission or the quality of the diagnostic image. The fixation adhesive strip anchors the cover to the catheter handle, preventing it from rolling up or shifting during the procedure. Being a sterile single-use product, it is especially indicated for procedures requiring aseptic conditions, immunocompromised patients or those allergic to latex. It must not be reused or re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Reference (SKU) | 88633PIP |
| Product type | Disposable protective cover for superficial ultrasound probe |
| Material | Synthetic medical-grade polyisoprene, free from natural latex |
| Latex content | Latex-free (hypoallergenic), suitable for allergy sufferers |
| Measurements | 8 x 30 cm (width x length) |
| Fixation | 1 adhesive fixation strip |
| Sterility | Sterile, individual packaging ready for use |
| Format | Flat, easy to apply and dispense |
| Compatibility | Superficial ultrasound catheters (linear, convex and sectorial) from leading brands |
| Applications | Superficial ultrasound imaging, diagnostic imaging, gynaecology and obstetrics |
| Use | Single-use, disposable. Do not reuse or re-sterilise |
| Presentation | Box of 10 units |
3.2. Advantages of the material
| Property | Benefit |
| High elasticity | Exact fit to the transducer head without folds |
| Strength and durability | Lower risk of breakage during examination |
| Effective barrier | Protection against cross-contamination |
| Acoustic conductivity | Does not interfere with the quality of the ultrasound image |
| Excellent feel | Greater patient comfort and ease of handling |
| Adhesive fixation | The cover remains stable on the handle throughout the examination |
4. Equivalences and Cross-References
This cover belongs to the Cahnos Ultra Cover™ PIP family of latex-free polyisoprene protectors, in which the size, sterility and inclusion of a cable protector vary according to the application. The closest variant is reference 88652PIP, which offers the same cover size of 8 x 30 cm in sterile version and also incorporates a polyethylene cable protector of 10 x 150 cm. For transducers with a smaller contact surface, the range of sterile covers with adhesive strip is completed with the 88667PIP (6 x 30 cm, sterile). Cahnos also offers non-sterile versions of the same family: 88653PIP (6 x 30 cm) and 88663PIP (2.6 x 30 cm), in a box of 100 units, and the superficial version of 4 x 30 cm (88694PIP).
| Reference | Measurements | Sterility | Presentation |
| 88633PIP (this) | 8 x 30 cm, with adhesive strip | Sterile | Box of 10 units |
| 88652PIP | 8 x 30 cm + cable 10 x 150 cm | Sterile | Box of 10 units |
| 88667PIP | 6 x 30 cm, with adhesive strip | Sterile | Box of 10 units |
| 88694PIP | 4 x 30 cm | Sterile | Box of 10 units |
| 88653PIP | 6 x 30 cm | Non-sterile | Box of 100 units |
| 88663PIP | 2.6 x 30 cm | Non-sterile | Box of 100 units |
At market level, this cover acts as a functional equivalent of the latex-free superficial protectors distributed by manufacturers such as Dahlhausen (refs. 42.200.26.301, 26 x 300 mm, and 42.200.30.201, 30 x 200 mm), of the sterile polyurethane ranges of the PULL UP™ type (refs. 1-519-2524 and 1-519-2548) and of Parker’s Eclipse pre-gelled covers with Aquasonic 100 gel (ref. E38-03), interchangeable for the purpose of transducer protection barrier in superficial ultrasound imaging.
5. Selection tips and variants of interest
To choose the right cover, you must verify two parameters: the working width and length of your superficial transducer, and the level of asepsis required by the procedure. The 8 x 30 cm size of this reference is ideal for linear and convex catheters with a large contact surface; if your equipment has a smaller footprint, consider the variants of 6 x 30 cm (88667PIP or 88653PIP), 4 x 30 cm (88694PIP) or 2.6 x 30 cm (88663PIP).
If you also need to protect the transducer cable, reference 88652PIP with a 10 x 150 cm cable protector is the family option with integral protection. For patients with latex allergy or sensitivity, latex-free polyisoprene is a safe and well-tolerated option. As it is a single-use product, we recommend calculating the centre’s monthly consumption to ensure continuous supply and to benefit from special B2B conditions for hospitals, clinics and purchasing centres. Consult our technical-commercial department at Cahnos to confirm exact compatibility with your fleet of ultrasound scanners and to define the most appropriate reference for each examination protocol.





Reviews
There are no reviews yet.