Description
Sterile latex-free protection for ultrasound catheters
The preoperative ultrasound catheter cover Surgi Poli Cover™ (ref. PC3688) is the disposable protection solution designed for preoperative and intraoperative ultrasound procedures where the safety of the patient and the healthcare professional is a priority. Made with a polyisoprene tip, a synthetic polymer completely free of natural latex, it eliminates the risk of allergic reactions in sensitised patients and in staff handling the catheter, while maintaining excellent tactile sensitivity and clear acoustic transmission during the examination. Each box includes 20 complete kits, ideal for operating theatres, interventional radiology and diagnostic imaging units.
Technical explanation and clinical application
This cover features a straight polyisoprene tip measuring 13 x 244 cm and a protection section of 3 cm, allowing it to cover the transducer and the entire cable up to 2.4 metres, extending the sterile field in surgical environments. The body of the protection is made of soft-touch polyethylene and the straight tip adapts to the geometry of linear and convex transducers with a straight end. Presented sterile and telescopically rolled, it unfolds over the catheter without touching its inner surface, maintaining asepsis until the moment of use. Each kit contains: 1 protective cover, 1 sterile gel sachet, 2 fixing elastic bands and 2 adhesive strips. Its use is indicated in preoperative ultrasound, image-guided procedures in the operating theatre, interventional radiology and diagnostic examinations that require a single-use sterile barrier, avoiding cross-contamination between patients. Disposable product: do not reuse or re-sterilise.
Technical specifications
| Reference | PC3688 |
| Material | Latex-free polyisoprene tip + soft-touch polyethylene body |
| Measurements | 13 x 244 cm |
| Protection section | 3 cm |
| Tip shape | Straight |
| Sterility | Sterile, single-use |
| Folding | Telescopic rolling |
| Kit contents | 1 cover, 1 sterile gel sachet, 2 elastic bands and 2 adhesive strips |
| Presentation | Box of 20 units |
| Application | Preoperative and intraoperative, linear and convex transducers |
Comparison of the Surgi Poli Cover™ range
| Reference | Dimensions | Section | Features | Units/box |
| PC4515 | 15 x 244 cm | 6 cm | Polyisoprene tip, large T-shape model, latex-free | 20 |
| PC3687 | 15 x 244 cm | 3 cm | Polyisoprene tip, small T-shape model, latex-free | 20 |
| PC3688 | 13 x 244 cm | 3 cm | Cover with straight polyisoprene tip, latex-free | 20 |
It is recommended to apply ultrasound coupling gel between the catheter and the cover to ensure optimal image transmission.
Equivalences and cross-references
The Surgi Poli Cover™ family is the latex-free variant of the Surgi Cover™/Surgi-Tip™ system from CIVCO Medical Solutions, whose original references for the 15.2 x 244 cm (6″ x 96″) format are 610833 (NeoGuard™ 3 cm tip with clips) and 610834 (20 x 244 cm format). In the Cahnos catalogue, the sister references of this same range are PC3687 (small T-shape model, 15 x 244 cm, 3 cm) and PC4515 (large T-shape model, 15 x 244 cm, 6 cm). As alternatives from other latex-free ranges for intraoperative catheters, 610797 (Surgi-Boot™, 15.2 x 244 cm) and 610941 (laparoscopic cover with fitted tip and clips) can be considered.
Selection tips and variants of interest
To choose the appropriate reference, assess the transducer geometry: the PC3688 (straight tip, 13 x 244 cm) is designed for linear or convex catheters with a straight end and a footprint of up to 3 cm section; the PC3687 (small T, 3 cm) adapts to catheters with a reduced footprint and T-shaped tip, and the PC4515 (large T, 6 cm) is the one indicated for larger-surface intraoperative transducers. If you work with patients or staff with latex allergy or sensitivity, this polyisoprene range is the recommended alternative to natural latex covers. For high-volume orders, the presentation in a box of 20 units optimises the cost per kit and ensures replenishment in the operating theatre, examination rooms and interventional radiology units. If you have any doubts about the most suitable reference for your catheter model, please consult our technical-commercial team.