Description
1. Introduction
When the sterilisation department needs to package medium and large instruments, trays or bulky packages, the paper bag with gusset of 250 x 480 x 60 mm from Pergut Medical Sterimed (Ref. 17) is the professional reference solution. It combines a microbial barrier of medical-grade paper, a 60 mm gusset that provides internal capacity and a high-fold adhesive closure that does not require a sealing machine. A robust, verifiable option ready for daily use in hospitals, clinics, laboratories and practices.
2. Technical Explanation
This bag is manufactured from medical-grade paper with controlled porosity and water-repellent treatment: the porosity allows the sterilising agent to enter and exit during the cycle, while the paper structure retains microbial contamination and resists moisture, protecting the contents. The 60 mm gusset opens up the internal volume of the packaging, allowing bulky instruments to be accommodated without stressing the closure areas.
The self-adhesive high-fold closure system seals the bag by simple pressure, without the need for a heat sealer. It incorporates a type 1 water vapour chemical indicator (ISO 11140-1) printed on the paper, which changes colour when the cycle is complete and allows visual verification of the process. The packaging is compatible with sterilisation by steam, gas (ethylene oxide) and gamma rays, and complies with UNE EN 868-4 and ISO 11607-1. It is a single-use packaging: it must not be re-sterilised.
3. Technical Specifications
Technical data sheet for reference 17
| Characteristic | Detail |
|---|---|
| Official reference | 17 (verified in the size programme of the official Pergut Medical catalogue) |
| Dimensions (width x length x gusset) | 250 x 480 x 60 mm |
| Material | Medical-grade paper with controlled porosity, water-repellent |
| Sterilisation methods | Steam, gas (ethylene oxide) and gamma rays |
| Chemical indicator | Steam, type 1 according to ISO 11140-1 |
| Closure system | Self-adhesive folded closure (pressure seal, no heat sealer) |
| Gusset | 60 mm, suitable for medium and bulky devices |
| Presentation | Box of 500 units |
| Scope of use | Sterilisation departments, operating theatres, clinics and laboratories |
Standard size programme of paper bags with steam indicator (official Pergut Medical catalogue)
| Reference | Dimensions (mm) | Units/box |
|---|---|---|
| 7B | 90 x 250 x 50 | 1000 |
| 8C | 110 x 190 x 30 | 1000 |
| 10R | 125 x 250 x 50 | 1000 |
| 11D | 140 x 250 x 75 | 1000 |
| 12F | 140 x 330 x 50 | 1000 |
| 15H | 180 x 380 x 95 | 500 |
| 22E | 190 x 250 x 65 | 1000 |
| 23P | 190 x 330 x 65 | 500 |
| 16M34 | 250 x 380 x 100 | 500 |
| 17 (this product) | 250 x 480 x 60 | 500 |
| 19 | 250 x 480 x 100 | 500 |
| 30M | 300 x 530 x 75 | 250 |
| 51T | 380 x 510 x 125 | 250 |
| 61M36 | 380 x 610 x 125 | 250 |
Standards and compliance
| Property | Value |
|---|---|
| Steam chemical indicator | Type 1, conforming to ISO 11140-1 |
| Packaging conformity | UNE EN 868-4 and ISO 11607-1 |
| Microbial barrier | Controlled porosity of medical-grade paper |
| Classification | Medical device Class I (MDR 2017/745), sterilisation packaging |
| Recommended storage | Cool, dry place (10–30 °C, 30–60 % relative humidity), in its original packaging |
| Use | Single-use container; do not re-sterilise |
4. Equivalences and Cross-References
Reference Cahnos 17 corresponds to the 250 x 480 x 60 mm format included in the standard size programme of the official Pergut Medical catalogue (paper bags with steam indicator), in a box of 500 units. Code verification status: confirmed against the manufacturer’s official programme.
Within Pergut Medical’s own family, the closest references in geometry are:
| Reference | Dimensions (mm) | Units/box | Difference compared to ref. 17 |
|---|---|---|---|
| 16M34 | 250 x 380 x 100 | 500 | Same width, shorter and with a 100 mm gusset |
| 17 (this product) | 250 x 480 x 60 | 500 | Analysed format |
| 19 | 250 x 480 x 100 | 500 | Same width and length dimensions, with a 100 mm gusset |
| 30M | 300 x 530 x 75 | 250 | Wider, longer and with a 75 mm gusset |
| 51T | 380 x 510 x 125 | 250 | Wider and with a 125 mm gusset |
| 61M36 | 380 x 610 x 125 | 250 | Wider, longer and with a 125 mm gusset |
These are not 1:1 crossovers between sizes: the gusset (60 mm versus 100 or 125 mm) and the exact dimensions vary, so they should be treated as variants of the same range and not as identical products.
At category level (comparable, not interchangeable 1:1), there are medical-grade paper bags with gusset from other manufacturers in the hospital sterilisation sector (for example, paper ranges with gusset and steam indicator such as Steriking, AMCOR or SPS Medical / Sterilisation and Packaging Specialists). Before proposing them in a tender, it is advisable to verify against the corresponding manufacturer’s technical data sheet and IFU, as they may differ in exact dimensions, paper grammage and closure configuration. There is no manufacturer-validated equivalence table for the 1:1 crossover of this reference with other brands; consult the technical department before using in a tender.
5. Selection tips and variants of interest
- Format selection: the packaging must comfortably exceed the device size, leaving a minimum margin of 10 mm on each side relative to the sealing areas. The 250 x 480 x 60 mm bag is ideal for instrument sets, scissors, long forceps, guides and medium-to-large devices; the 60 mm gusset provides additional volume for bulky material.
- Variants of the same family: if you need more internal capacity with the same dimensions, consider reference 19 (250 x 480 x 100 mm); for shorter instruments, reference 16M34 (250 x 380 x 100 mm); for long pieces, references 30M (300 x 530 x 75 mm), 51T (380 x 510 x 125 mm) or 61M36 (380 x 610 x 125 mm).
- Without a sealing machine: the high-fold adhesive closure allows sealing by simple pressure; if you have a heat sealer, you may consider as a functional alternative the paper-film mixed bags from the BOP TI/DI range.
- Cycle verification: the paper is suitable for steam, gas and gamma rays; always check the colour change of the chemical indicator at the end of the cycle before validating the process.
- Good practices: record batch, date and contents on the label, store the bag in a cool, dry place until use and respect the single-use principle (do not re-sterilise).