We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Long Cannulated Cleaning Brush 610 x 7 mm with Polyamide Bristles and Braided Stainless Steel Guide Wire (Ref. TR150483-3) · Box of 3 units

16,75 €

Long cannulated cleaning brush of 610 mm and 7 mm bristle diameter, with braided stainless steel guide wire and polyamide (nylon) bristles resistant to wear and sterilisation cycles. Designed for the interior washing and decontamination by steam (autoclave) of cannulas, tubes, suction cannulas and medium-calibre tubular instruments in sterilisation departments, operating theatres and clinics. Reusable Class I medical device with CE marking, presented in a box of 3 units. Reference TR150483-3 (equivalent to 12122 from Pergut Medical).

International shipping. Import duties and taxes are payable by the recipient.

Reference
123121220000

Description

The Long Cannulated Cleaning Brush 610 x 7 mm (Ref. TR150483-3) is the professional reference tool for the decontamination and maintenance of cannulated medical instruments in sterilisation departments, operating theatres, clinics and reprocessing services. Its combination of braided stainless steel guide wire and polyamide bristles ensures deep, safe and repeatable cleaning of the inside of devices, extending the service life of your instrument inventory and ensuring compliance with the most demanding hygiene protocols. Available in a box of 3 units for your operational convenience.

Technical explanation of the product and procedure

Cannulated devices, such as cannulas, tubes, suction cannulas and tubular instruments, accumulate organic debris and biofilms in their lumen that surface washing does not remove and that prevent the effective action of the sterilising agent. This brush allows mechanical brushing of the inside of the lumen, an essential prior step in the decontamination chain: pre-cleaning, washing and steam sterilisation in an autoclave.

The braided stainless steel guide wire provides flexibility, chemical resistance and durability, allowing the bristles to be guided through channels up to 610 mm in length. The polyamide (nylon) bristles offer firm but non-abrasive brushing, which respects the integrity of the instrument’s internal walls and withstands repeated sterilisation cycles. It is a reusable product, classified as a Class I medical device with CE marking.

Technical specifications

Characteristic Specification
Reference TR150483-3
SKU Cahnos 123121220000
Total length (wire) 610 mm
Working diameter (bristles) 7 mm
Bristle material Polyamide (nylon)
Wire material Braided stainless steel
Decontamination Washable and sterilisable by steam (autoclave)
Application Interior cleaning of medium-calibre cannulated devices
Reusable Yes
Classification Class I medical device with CE marking
Presentation Box of 3 units

The long series of nylon cannulated brushes is completed with the following sizes, all from the same construction family (braided stainless steel guide wire and polyamide bristles):

Reference Bristle diameter Wire length Units per box
TR150483-3 (this product) 7 mm 610 mm 3
TR150221-3 5 mm 610 mm 3
TR160617-3 10 mm 610 mm 3
TR360231-3 2.5 mm 610 mm 3

Equivalences and cross-references

This brush corresponds to reference 12122 of the series of brushes for manual cleaning of cannulated instruments from the manufacturer Pergut Medical (7 mm diameter and 610 mm guide wire), so ref. TR150483-3 is interchangeable with 12122 in orders and replenishments. It is part of a complete range of nylon cannulated brushes: long (TR150221-3 of 5 mm, TR150483-3 of 7 mm, TR160617-3 of 10 mm and TR360231-3 of 2.5 mm), medium and short (TR350232-3 of 3 mm, TR350109-3 of 2.3 mm, TR350354 of 5 mm and TR350429 of 6 mm), with rigid guide wire (refs. 4034, 4035 and 241045) and specific for valve cleaning (45918). On the market, this tool corresponds to channel cleaning brushes from manufacturers such as STERIS, the CISA Brasile brush line and the brushes for cannulated instruments from Igaltex, all based on the same principle of bristles mounted on a braided shaft for the removal of debris in lumens with direct access. For the validation of exact equivalences with the references your centre currently uses, our technical-commercial department will advise you without obligation.

Selection tips and variants of interest

To choose the right brush, select a bristle diameter slightly smaller than the internal diameter of the lumen to be cleaned, so that the bristles press gently against the walls without jamming, and a guide wire length that covers the total depth of the channel. The 7 mm model (TR150483-3) is ideal for cannulas and medium-calibre instruments with straight or deep access. If the lumen has a larger passage, opt for the 10 mm variant (TR160617-3); for narrower channels, the 5 mm (TR150221-3) or 2.5 mm (TR360231-3) models; for shallow channels, the mediana series of 300 mm (TR350232-3 and TR350109-3). For cleaning rigid components, the rigid guide wire range is suitable (refs. 4034, 4035 and 241045). All models in the family are washable and steam sterilisable, complying with the standard protocols of sterilisation departments. For replenishment orders, purchasing centres and special volume conditions, consult our technical-commercial department at Cahnos.

Additional information

Bristle material

Polyamide (nylon)

Wire material

Braided stainless steel

Bristle diameter

7 mm

Sterilisation

Washable and sterilisable by steam (autoclave)

Presentation

Box of 3 units

Reference

TR150483-3

Classification

Class I medical device with CE marking

Application

Interior cleaning of medium-calibre cannulated devices

Longitud

61 cm

Tipo uso

Reusable

Reviews

There are no reviews yet.

Be the first to review “Long Cannulated Cleaning Brush 610 x 7 mm with Polyamide Bristles and Braided Stainless Steel Guide Wire (Ref. TR150483-3) · Box of 3 units”

Your email address will not be published. Required fields are marked *