Bowie-Dick Helix-type Test for Steam Sterilisation – Device with 1.5 m x 2 mm lumen and self-adhesive indicator strip of 6 x 76 mm – Box of 20 units (Ref. BD125X/20)

83,33 €

Bowie-Dick Helix-type test to validate air removal and steam penetration in vacuum-assisted steam sterilisation equipment, both large and small. Includes metal capsule, 1.5 m x 2 mm lumen polyamide tube with silicone protective connector and self-adhesive indicator strip of 6 x 76 mm. Presentation in box of 20 units, single-use, ideal for routine process control in sterilisation centres. Conforms to ISO 11140-1 and ISO 11140-4. Ref. BD125X/20.

International shipping. Import duties and taxes are payable by the recipient.

Reference
BD125X/20

Description

1. Product Presentation

The Bowie-Dick Helix test pack (Ref. BD125X/20) is the process control solution that sterilisation centres need to quickly and reliably verify the correct removal of air and penetration of saturated steam in vacuum-assisted autoclaves, both large and small. Each box includes 20 single-use units, ready to be incorporated into the daily validation routine of the sterilisation service, hospitals and medical device processing companies.

Manufactured by Pergut Medical and distributed by Cahnos in Spain, this device combines a metal capsule, a polyamide tube of 1.5 m x 2 mm lumen with a protective silicone connector and a self-adhesive paper indicator strip of 6 x 76 mm, reproducing the most challenging hollow load condition according to the guidelines of the ISO 11140-4 standard.

2. Technical explanation of the procedure

The Bowie-Dick test is a steam penetration test used to monitor the air removal efficiency of steam sterilisers with dynamic air extraction (pre-vacuum and vacuum pump). If residual air pockets remain in the chamber, the steam does not reach the load surface under saturation conditions and the sterilisation process may not be effective, even if the recorded temperature and time parameters are correct.

The Helix design reproduces the worst-case hollow load scenario: the steam must travel through a polyamide lumen 1.5 m long with only 2 mm internal diameter before reaching the indicator strip. The metal capsule protects the reading area and the silicone connector ensures a seal and a secure connection to the equipment. The self-adhesive paper strip of 6 x 76 mm, printed with steam-sensitive ink, changes colour only when the air has been removed and the saturated steam has penetrated under correct conditions, allowing the load to be released safely.

This device is classified as a chemical indicator Type 2 (ISO 11140-1) and its use is recommended for the Bowie-Dick test according to the ISO 11140-4 standard.

3. Technical Specifications

Device technical data sheet

Characteristic Specification
Type B&D Helix test for steam
Reference BD125X/20
Device dimensions 1.5 m length x 2 mm lumen
Indicator strip Self-adhesive paper 6 x 76 mm
Composition Metal capsule, polyamide tube with protective silicone connector and self-adhesive paper strip
Presentation Box of 20 units
Processing Steam in large and small vacuum-assisted sterilisation equipment
Application Assessment of air removal and steam penetration
Classification Chemical indicator Type 2 / Type S2 (ISO 11140-1)
Storage No special conditions required; keep in original packaging until use
Use Single-use, disposable
Conformity ISO 11140-1 (Type S2) and ISO 11140-4
CE marking No (product conforms to the ISO 11140-1/-4 standards)

Typical Bowie-Dick cycle conditions

Parameter Value
Reference pre-vacuum cycle 134 °C for 3.5 minutes
Alternative cycle 132 °C for 4 minutes
Parameter evaluated Air removal and saturated steam penetration
Conforming result Uniform and complete colour change of the indicator strip
Non-conforming result Insufficient or irregular strip change: check vacuum system and process

4. Equivalences and Cross-References

This pack belongs to the family of Helix process challenge devices from the Spanish manufacturer Pergut Medical. The manufacturer’s technical reference whose dimensions and composition match this device is KH2X15-35B (B&D Helix test for steam), conforming to ISO 11140-1 Type S2 and ISO 11140-4. Within the same family, the following references of interest are found:

Reference Description Presentation
KH2X15-35B B&D Helix test for steam (technical equivalent of this product) On request
KH2X15-35 Helix Test PCD kit + simulation strips for steam 250 strips/box
BD125X/1 Bowie-Dick test package with pre-notice sheet 20 uds/caja
24102 Bowie-Dick test package for daily control (120 x 120 x 17 mm) 20 uds/caja
KH2X12-P1 Helix Test PCD Kit + strips for plasma 100 uds/caja
KH2X15F1P Helix Test PCD Kit + strips for formaldehyde 250 uds/caja

For hollow load validation purposes, this device is functionally interchangeable with other Helix-type tests conforming to ISO 11140-4, as it exactly meets the 1.5 m x 2 mm lumen geometry required by the market standard for this type of process control.

5. Selection tips and variants of interest

  • Hollow load control: if your autoclave processes long-lumen instruments (endoscopy, laparoscopy, cannulas, etc.), the Helix-type test is the right one. For daily monitoring of large autoclaves with a vacuum pump, the classic reference is the Bowie-Dick pack 24102.
  • Frequency of use: perform the B&D test at least once a day, with the chamber empty and following the equipment manufacturer’s protocol and the ISO 11140-1 standard.
  • Other processes: if you need to validate plasma (hydrogen peroxide vapour) or formaldehyde cycles, the same family offers versions KH2X12-P1 and KH2X15F1P.
  • Complementary consumables: for a complete set, combine this pack with B&D simulation strips and steam biological indicators, available in the Cahnos catalogue.
  • Storage and handling: keep the product in its original packaging until the moment of use; it is single-use and must not be re-sterilised. Always check the integrity of the packaging before each cycle.
  • Professional B2B purchasing: for sterilisation centres, hospitals and processing companies, contact our technical-commercial team for volume and continuous supply conditions.

Additional information

Product type

Bowie-Dick Helix test for steam

Reference

BD125X/20

Material

Metal capsule, polyamide tube with protective silicone connector and self-adhesive paper strip

Device dimensions

1.5 m length x 2 mm lumen

Indicator strip dimensions

6 x 76 mm

Indicator type

Self-adhesive strip chemical indicator (paper)

Process

Steam in vacuum-assisted sterilisation equipment

Application

Assessment of air removal and steam penetration

Presentation

Box of 20 units

Regulatory standard

ISO 11140-1 (Type S2) and ISO 11140-4

Storage

No special conditions required; keep in original packaging

Use

Single-use, disposable

Certifications

No (product conforms to ISO 11140-1/-4)