Description
1. Commercial Introduction
Protect your patients, your team of professionals and your spirometer with the 28 mm bacterial and viral filter (ref. 08268), the reference disposable consumable for spirometry testing on Sibelmed equipment. Compatible with the Datospir Touch, Datospir Micro A-B-C, Datospir 120 A-B-C-D and Datospir 6020 F-T models, this filter is installed in line between the patient and the equipment, acting as a hygienic barrier against bacteria and viruses and preventing cross-contamination between patients and professionals.
Its integrated oval ergonomic mouthpiece eliminates the need to add additional accessories, reducing the cost per test. It is supplied in a box of 100 units, the most cost-effective format for pulmonology clinics, primary care, mutual insurance companies, occupational health services and pulmonary function laboratories with a high turnover of tests. Medical device class IIa under Directive 93/42/EEC, with immediate availability for direct shipment.
2. Technical explanation of the procedure
During spirometry, the patient performs forced breathing manoeuvres through the spirometer circuit, which records parameters such as forced vital capacity (FVC), forced expiratory volume in the first second (FEV1) or peak expiratory flow (PEF). The European scientific societies (ERS) and SEPAR recommend that all pulmonary function tests be performed with a disposable bacterial and viral filter to prevent the spread of aerosols and reduce the risk of infection between patient and technician.
This type of filter combines an electrostatic and mechanical filtration method on a high-efficiency polypropylene membrane that retains particles, bacteria and viruses, maintaining low flow resistance and reduced dead space, so that it does not distort flow and volume measurements under BTPS conditions. As a single-use consumable, it simply needs to be replaced for each patient to maintain an impeccable hygiene protocol, with no need for reprocessing or disinfection of the circuit.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Diameter | 28 mm |
| Filter type | Bacterial and viral, disposable, single-use |
| Mouthpiece | Integrated, oval ergonomic design; no additional mouthpiece required |
| Bacterial filtration efficiency | 99.99999 % (at 30 l/min) / 99.9943 % (at 750 l/min) |
| Viral filtration efficiency | 99.9981 % (at 30 l/min) / 99.7680 % (at 750 l/min) |
| Flow resistance | < 1.45 hPa/l/s (1.5 cm H2O/l/s) at 14 l/s |
| Dead space | < 75 ml |
| Filtration method | Electrostatic and mechanical |
| Membrane material | High-efficiency polypropylene |
| Weight | 52 g |
| Regulatory classification | Medical device class IIa (Directive 93/42/EEC) |
| Compatible brand | Sibelmed |
| Compatible models | Datospir Touch, Datospir Micro A-B-C, Datospir 120 A-B-C-D and Datospir 6020 F-T |
| Presentation | Box of 100 units |
| Reference / SKU | 08268 |
Indicative compatibility by model:
| Spirometer model | Field of application |
|---|---|
| Datospir Touch | Desktop equipment with 28 mm connection |
| Datospir Micro A-B-C | Portable spirometers from the Micro family |
| Datospir 120 A-B-C-D | Desktop spirometers, series 120 |
| Datospir 6020 F-T | Equipment from the 6020 series |
Note: compatibility depends on the equipment connection size (28 mm for this filter). Always check the connection diameter of your spirometer before placing the order.
Reference data from the compatible manufacturer (official Sibelmed filter for the 28 mm size, consumables catalogue FG SIB1201_ES):
| Parameter | Reference value |
|---|---|
| Bacterial filtration efficiency | 99.99999 % (at 30 l/min) / 99.9943 % (at 750 l/min) |
| Viral filtration efficiency | 99.9981 % (at 30 l/min) / 99.7680 % (at 750 l/min) |
| Flow resistance | < 1.45 hPa/l/s (1.5 cm H2O/l/s) at 14 l/s |
| Dead space | < 75 ml |
| Filtration method | Electrostatic and mechanical |
| Membrane material | High-efficiency polypropylene |
| Weight | 52 g |
| Mouthpiece | Integrated, oval ergonomic design; no additional mouthpiece required |
4. Equivalences and Cross-References
The 28 mm diameter with integrated mouthpiece is the standard size for spirometers in the Datospir-Sibelmed family. The following commercial references have been cross-checked against official manufacturer or authorised distributor documentation:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Sibelmed | Disposable 28 mm bacterial/viral filter (box of 100) | 09698 | Comparable by category (not interchangeable 1:1) | Official manufacturer reference for the 28 mm size in Datospir-Sibelmed and Evernoa nitric oxide monitor; specifications matching the family of this product (bacterial and viral efficiencies of 99.99 %, class IIa, integrated oval mouthpiece). Code verified in the official Sibelmed consumables catalogue (FG SIB1201_ES). |
| DH Medical (authorised distributor) | Disposable 28 mm Datospir bacterial/viral filter (box of 100) | 110509698 | Comparable by category (not interchangeable 1:1) | Same size (28 mm) and same declared efficiencies (bacterial 99.99999 % and viral 99.9981 %), class IIa according to 93/42/EEC; compatible with Datospir, Pinnacle, Vitalograph, MIR and Cosmed. Repackager/distributor code; check batch labelling. |
There is no equivalence table validated by the manufacturer that allows these references to be declared as 1:1 interchangeable; consult the technical department before use in tenders. Other brands in the sector (Intersurgical with its Pulmo-Protect™ range, Vyaire/CareFusion with MicroGard™) offer high-efficiency spirometry filters, but with connection sizes of 30 mm or 34.5 mm; always check the connection diameter of your equipment before replacing this 28 mm filter.
5. Selection tips and variants of interest
Check the connection size: this filter is 28 mm, the specific size for the Datospir-Sibelmed family. For portable spirometers from other brands (MIR, Cosmed, nSpire, Vitalograph, Micromedical and Clement Clarke) select the 30 mm filter (ref. 08269) and for Jaeger, SensorMedics, Viasys and CareFusion MasterScreen pulmonary function platforms the 34.5 mm one (ref. 08289).
Replace per patient: as it is a single-use consumable, change it for each spirometry and keep stock by the box of 100 units to avoid interrupting clinical activity.
Complete the test kit: combine the filter with cardboard mouthpieces compatible with Datospir-Sibelmed (refs. 01555, 28 ext. × 60 mm, or 01554, 30 ext. × 60 mm) and with the disposable nasal clip (ref. 02692) for a complete hygienic protocol.
Calibration: if you carry out periodic checks, remember to validate the equipment with the 3-litre calibration syringe (ref. 08290) to maintain the certified accuracy of ±0.5 %. For preventive maintenance, you also have the disposable Lilly transducer (ref. 03169) for Datospir Touch, 120, 110 and 600.
Equip your practice or laboratory with trusted consumables: we have immediate stock for direct shipment.





Reviews
There are no reviews yet.