Description
1. Introduction
We present the replacement SpO2 probe for adults from the manufacturer (ref. 33695), the official replacement for the oximetry sensor supplied with the SPIROLAB 33520 spirometer. It is a reusable finger clip that restores the measurement of oxygen saturation and pulse rate on your equipment without the need to purchase a new spirometer.
It is the ideal solution for pulmonology departments, sports medicine, primary care and respiratory functional diagnostic units that work with oximetry integrated into spirometry testing and need to replace the original probe of the equipment. As a manufacturer’s spare part, it guarantees connector compatibility and signal reliability in every measurement.
2. Technical explanation
Pulse oximetry (SpO2) is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin and pulse rate by spectrophotometry. This finger clip integrates the emitter and photodetector in a single clip-type body that attaches to the patient’s finger: the emitter projects red and infrared light through the vascular bed and the detector quantifies the differential absorption according to the degree of blood oxygenation, transmitting the signal to the spirometer, which processes it and displays the values in real time.
In the SPIROLAB 33520 spirometer, the adult SpO2 probe is the standard sensor of the integrated oximetry option, which allows SpO2 to be recorded during spirometric manoeuvres and in saturation tests. The reusable replacement sensor allows occasional or continuous monitoring with quick, stable and ergonomic placement on adult patients.
3. Technical Specifications
This probe is supplied as a replacement part (spare part) of the original sensor of the spirometer with oximetry SPIROLAB 33520 (manufacturer ref. 33695). Always verify the reference of your equipment before requesting the replacement.
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Spare part |
| EAN | 8023279336955 |
Technical features
| Manufacturer reference | 33695 |
|---|---|
| Catheter type | Reusable SpO2 finger clip (finger probe) |
| Patient population | Adult |
| Compatibility | Spirometer SPIROLAB 33520 with oximetry option (standard adult sensor) |
| Measured parameters | Oxygen saturation (SpO2) and pulse rate |
| Use | Replacement (spare) |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| GM33695 | Replacement adult SpO2 probe for SPIROLAB 33520 spirometer (ref. 33695) | 1 pc |
4. Equivalences and Cross-References
Reference 33695 is a manufacturer-specific catalogue code for this replacement SpO2 probe. The manufacturer uses proprietary connectors by equipment family, so we do not have a manufacturer-validated equivalence table that cross-references this probe with codes from other brands on a 1:1 interchangeable basis. Before replacing any pulse oximeter or spirometer with oximetry probe, always verify the compatibility of the connector and communication protocol with the exact brand and model of your equipment.
Within the same range, the reusable adult SpO2 finger clips intended for other equipment (e.g., refs. 35153 and 35329 for monitors and pulse oximeters in the family) are similar in category and application point, but not interchangeable with each other without verifying the connector and equipment model. For paediatric patients, the SPIROLAB 33520 spirometer has an optional reusable paediatric probe.
5. Selection tips and variants of interest
- Verify your equipment: this probe is the replacement for the oximetry sensor of the SPIROLAB 33520 spirometer. Always provide the full reference of your equipment to confirm compatibility before placing the order.
- Choose the correct population: for adult patients this is the indicated probe (standard sensor). If your centre also treats paediatric patients, consult the optional reusable paediatric probe for the same spirometer.
- Maintenance: as a reusable probe, clean the clip between patients with a soft cloth or compatible disinfectant solution, without submerging it, and keep the cable free of sharp bends to extend its service life.
- Stock management: as an official spare part, we recommend keeping one replacement unit per equipment to avoid interruptions in oximetry testing.
- B2B conditions: For large orders you can request a quote. Consult our technical-commercial department at Cahnos for terms, lead times and availability.