We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Digital Peak Expiratory Flow Meter PF100 for Asthma – Measures PEF and FEV1, Memory for 240 Records and USB Connection

120,00 €

Digital peak expiratory flow meter PF100: high-precision portable device for asthma control. It measures peak expiratory flow (PEF) from 50 to 900 l/min and forced expiratory volume in 1 second (FEV1) from 0.01 to 9.99 litres, with memory for 240 measurements with date and time and included analysis software. It connects via USB to the computer to manage the patient’s respiratory profile and carry out clinical follow-up of the treatment.

International shipping. Import duties and taxes are payable by the recipient.

Reference
PF100

Description

1. Commercial Introduction

The digital peak expiratory flow meter PF100 is the professional and home solution for effective control of asthma and other respiratory conditions. Its portable design, 240-record memory and USB connection make it the perfect ally for both the patient who needs daily self-monitoring and the healthcare professional who requires reliable and documented data. It includes clinical analysis software to interpret the patient’s progress and facilitate communication with the specialist.

2. Technical explanation of the equipment

The PF100 is an electronic asthma monitor that measures two key parameters of lung function: the peak expiratory flow (PEF), which is the maximum speed at which air leaves the lungs after a full inspiration, and the forced expiratory volume in the first second (FEV1), the volume of air exhaled during the first second of a forced expiration. Both indicators allow detection of airway obstructions and objective monitoring of the disease.

Measurement is performed by blowing forcefully through the mouthpiece; a rotating vane sensor records the flow and the device displays the PEF result for about 3 seconds, followed by the FEV1 value. The device incorporates a traffic light system (green, yellow and red) with a reference value of 500 l/min for intuitive self-assessment: green above 400 l/min, yellow between 300 and 400 l/min and red below 300 l/min. It stores up to 240 measurements with date and time, and when the memory is full, the oldest records are automatically overwritten. Data can be transferred to the computer via the USB port and analysed with the included software, which allows the traffic light limits to be configured individually. The mouthpiece and measuring tube are removable and washable to ensure hygiene between users.

3. Technical Specifications

Brand / model Microlife PF 100
Measured parameters PEF (peak expiratory flow) and FEV1 (forced expiratory volume in 1 s)
PEF measurement range 50 – 900 l/min
FEV1 measurement range 0.01 – 9.99 litres
Measurement method Rotating vane (rotating turbine)
PEF accuracy ±20 l/min or 10% of reading, whichever is greater
FEV1 accuracy ±0.1 l or ±5% of reading, whichever is greater
Resolution PEF 1 l/min; FEV1 0.01 l
Memory 240 measurements with date and time (EEPROM)
Connectivity USB port for data transfer to PC
Software Microlife Asthma Analyzer, included (traffic light configuration, reports and monitoring)
Self-assessment Traffic light system: green >400 l/min, yellow 300–400 l/min, red <300 l/min (reference value 500 l/min)
Power supply 2 batteries, 1.5 V, size AAA
Battery life Approx. 1,000 measurements
Dimensions 77 (width) x 144 (length) x 48 (height) mm
Weight 150 g (with batteries)
Protection class IP22
Operating conditions 10 – 40 °C, 10 – 85% maximum relative humidity
Storage conditions -5 to +50 °C, 10 – 90% maximum relative humidity
Regulatory standard CE, EN 60601-1, EN 60601-1-2, EN ISO 23747, IEC 60601-1-11, updated ATS 1994 standard
Expected service life 5 years or 10,000 measurements
Intended use Paediatric and adult patients, home monitoring and clinical support
Package contents PF100 device, mouthpiece, measuring tube, USB cable, software, asthma control card, wall bracket and carrying case

4. Equivalences and Cross-References

The PF100 belongs to the family of digital peak expiratory flow meters from Microlife. Its direct equivalents within the same range are the PF 200 model and its Bluetooth variant PF 200 BT, which share the same measurement parameters (PEF and FEV1) and the same analysis software. The Asthma Analyzer software is compatible with all three models and is available on the manufacturer’s website.

In the Cahnos catalogue, it can be complemented with the manual peak flow meter (ref. 0992059, adult and paediatric sizes), ideal as an economical self-monitoring alternative, and with the portable digital spirometers from the Datsopir range (refs. 02072 Micro A and 02073 Micro C), recommended when a complete spirometry with more than 1,000 stored tests is required. For respiratory patient assessment, it can also be combined with mouthpieces, disposable filters or nitric oxide monitors (ref. ANONBA10V1) available at Cahnos.

5. Selection tips and variants of interest

Choose the PF100 when you need a PEF/FEV1 measurement device with memory and data export for scheduled monitoring of the asthmatic patient, both in the clinic and at home. For basic and economical peak flow monitoring, the manual meter (ref. 0992059) is a valid alternative. If your centre requires complete diagnostic spirometry with curves and quality control, opt for the Datsopir Micro A (ref. 02072) or Micro C (ref. 02073) spirometers.

It is recommended to perform three or more measurements per session and record the highest value, preferably in the morning and in the evening before medication; the traffic light limits should be set together with the specialist. To maintain hygiene between patients, replace the mouthpiece and disinfect the measuring tube following the manufacturer’s instructions. The measurement is for self-monitoring and does not replace diagnosis or medication adjustment, which must always be medically supervised.

Additional information

Model

PF 100

Measured parameters

PEF (50–900 l/min) and FEV1 (0.01–9.99 l)

Measurement method

Rotating vane (rotating turbine)

PEF accuracy

±20 l/min or 10% of reading, whichever is greater

FEV1 accuracy

±0.1 l or ±5% of reading, whichever is greater

Resolution

PEF 1 l/min; FEV1 0.01 l

Memory

240 measurements with date and time (EEPROM)

Connectivity

USB port for PC

Software

Asthma Analyzer included

Traffic light system

Green >400 l/min, yellow 300–400 l/min, red

Power supply

2 batteries, 1.5 V, size AAA

Battery life

Approx. 1,000 measurements

Dimensions

77 x 144 x 48 mm

Weight

150 g (with batteries)

Protection class

IP22

Operating conditions

10–40 °C, 10–85% RH

Storage conditions

-5 to +50 °C, 10–90% RH

Regulatory standard

CE, EN 60601-1, EN 60601-1-2, EN ISO 23747, IEC 60601-1-11, ATS 1994

Intended use

Paediatric and adult; home and clinical monitoring

Contents

Device, mouthpiece, measuring tube, USB cable, software, control card, wall bracket and case

Shelf life

5 years or 10,000 measurements

Reviews

There are no reviews yet.

Be the first to review “Digital Peak Expiratory Flow Meter PF100 for Asthma – Measures PEF and FEV1, Memory for 240 Records and USB Connection”

Your email address will not be published. Required fields are marked *