Description
1. Commercial Introduction
The S3000-3L calibration syringe is the reference volumetric standard that every spirometry service needs to ensure its spirometer measures correctly. Designed for pulmonology professionals, primary care, occupational medicine, mutual insurance companies and pulmonary function laboratories, it provides a certified accuracy of ±0.5 % and a simple, fast and fully manual verification method, with no need for electronic maintenance or consumables. Available from immediate stock, sold per unit under reference Cahnos 08290.
2. Technical explanation of the equipment and procedure
The S3000-3L calibration and verification syringe is a device based on a cylindrical chamber and a plunger that is operated manually by pushing and retracting the piston. The outlet port connects to the spirometer’s flow transducer and, when actuated, it displaces a known volume of air (3 L) through the sensor, allowing the accuracy of respiratory volume measurement equipment to be checked under normal operating conditions.
The ATS/ERS 2005 (Standardisation of Spirometry) standardisation guidelines recommend daily verification of the spirometer with a 3-litre calibration syringe, and the ISO 26782:2009 standard requires it as a method of accuracy checking. Although some devices come pre-calibrated from the factory or do not require calibration, having a known standard is essential to know whether the device measures correctly and complies with quality control programmes. Quality protocols recommend inspection and recalibration of the syringe at least once a year.
3. Technical Specifications
The S3000-3L syringe consists of an aluminium cylinder with hard anodising, an aluminium, steel or thermoplastic polyamide plunger, an ABS plastic plunger handle and side plates in POM, PET or PBT plastic, according to the manufacturer’s technical documentation.
| Parameter | Specification |
|---|---|
| Model | S3000-3L (Sibelmed) |
| Accuracy | ±0.5 % (certified) |
| Total volume | 3 L (3000 ml) |
| Minimum graduation | 3000 ml |
| Plunger travel | 37.5 cm (14.75″) |
| Cylinder bore | 10.16 cm (4″) |
| Weight | 1.9 – 2.4 kg |
| Nozzle diameter | 28 mm (30 mm adapters according to technical data sheet) |
| Dimensions | 50 × 11.8 × 11.8 cm (current model) |
| Compatibility | Spirometers with standard flow transducer; Datospir / Sibelmed family; check adapter 28–30 mm |
| Applicable regulations | Regulation (EU) 2017/745; EN ISO 9001:2015 |
| Reference standard | ATS/ERS 2005; ISO 26782:2009 |
| Presentation | Individual unit |
| Reference / SKU | 08290 |
Consult the labelling and the declaration of conformity of the batch for the regulatory requirements required in your tender.
4. Equivalences and Cross-References
3-litre calibration syringes constitute a standardised market category: all of them displace a nominal volume of 3 L for the verification of spirometers according to ATS/ERS and ISO 26782:2009. However, 1:1 interchangeability depends on the declared accuracy, the coupling diameter to the transducer and the adapters supplied, so each candidate must be verified against the manufacturer’s data before replacing reference 08290. The following codes from other manufacturers have been located and verified:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| MIR | 3L calibration syringe for reusable and disposable turbines (Spirolab, Spirodoc, Spirobank II, Minispir, Spirotel) | 919000 | Comparable by category (not interchangeable 1:1) | Volume 3 L; accuracy ±0.25 % (higher than the ±0.5 % of the S3000-3L); includes adapters for tubes from 1″ to 1 1/16″ OD. Code verified on the official MIR website and authorised distributors. |
| Vitalograph | 3-Litre Precision Calibration Syringe (flow and volume systems, compatible with any manufacturer) | 36020 | Comparable by category (not interchangeable 1:1) | Volume 3 L; certified accuracy better than 0.5 %; each unit with a unique serial number and history; recommended for all spirometers according to ISO 26782:2009. Code verified on the official Vitalograph website. |
| Vyaire | Calibration Syringe, manual, 3 L (aluminium/acrylic) | 720254 | Comparable by category (not interchangeable 1:1) | Manual 3 L syringe calibrated at the factory; range of Vyaire/CareFusion/nSpire spirometers. Code verified with authorised distributors (CIA Medical, Grayline Medical); pending verification on a regulatory basis. |
| nSpire Health | KoKo Calibration Syringe, 3 L (KoKo Sx, Legend, PFT, Trek) | 510000 | Comparable by category (not interchangeable 1:1) | 3 L syringe for daily verification of nSpire KoKo spirometers; also commercially replaced by A-M Systems with ±0.25 % accuracy and CE marking. Code verified with authorised distributors (HCE, A-M Systems). |
There is no equivalence table validated by the manufacturer that cross-references this reference with codes from other brands on a 1:1 interchangeable basis; consult the technical department before using in a tender. Reference 08290 corresponds to the S3000-3L calibration syringe from the Sibelmed range, distributed by authorised suppliers in the sector; always verify the coupling diameter, declared accuracy and available adapters before replacing the model.
5. Selection tips and variants of interest
- Verify the coupling diameter: the nozzle of the S3000-3L is 28 mm (with 30 mm adapters according to the technical data sheet). Confirm the adapter for your flow transducer before purchase to ensure a hermetic, leak-free seal during the manoeuvre.
- Verification frequency: carry out the daily check with the 3 L syringe according to the ATS/ERS 2005 recommendations and ISO 26782:2009, and schedule inspection and recalibration of the syringe itself at least once a year within your quality control programme.
- Use with the Datospir range: it is the recommended complement for Datospir Aira spirometers (disposable transducer, turbine or Fleisch) and for the rest of the Datospir / Sibelmed family available in our catalogue (refs. 09063, 09064, 09065).
- Complete the circuit with consumables: for a hygienic and reliable manoeuvre, combine the verification with compatible cardboard mouthpieces (refs. 01555, 01554 or 01552) and spirometry bacterial/viral filters (refs. 08268/08269).
- Assess the accuracy according to your protocol: if your quality service requires stricter tolerances than ±0.5 %, consult our technical department about the 3 L alternatives with certified accuracy of ±0.25 % available on the market, and previously verify adapters and compatibility.





Reviews