Description
The reservoir valve (ref. 34279) is the connecting component that allows the oxygen reservoir bag to be attached to the manual ventilation circuit of the resuscitator. It is the part indicated by the manufacturer for use with the 2,500 ml oxygen reservoir bag (code 34275), especially in equipment such as the resuscitator Ref. 34200, which expressly requires this valve for operation with a reservoir.
Technical explanation of the accessory
In a manual resuscitator (bag-valve-mask system), the oxygen reservoir accumulates O₂ between one compression and the next so that each insufflation delivers to the patient a mixture enriched at high concentration. The reservoir valve acts as the flow control element: it directs oxygen from the reservoir bag to the ventilation bag during the re-expansion phase and prevents gas leaks, maintaining the available reserve and the tightness of the circuit. Its correct condition is essential to guarantee adequate FiO₂ in cardiopulmonary resuscitation manoeuvres and basic ventilatory support.
Technical specifications
| Product data | Detail |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 34279 |
| SKU Cahnos | GM34279 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II A |
| CND | R03020201 |
| EAN | 8023279342796 |
Available references
| Reference | Product | Sales unit |
|---|---|---|
| GM34279 (34279) | Oxygen reservoir valve for manual resuscitator | 1 pc |
Equivalences and cross-references
Reference 34279 (SKU Cahnos GM34279) is the reservoir valve indicated by the manufacturer for use with the 2,500 ml oxygen reservoir bag (ref. 34275 / GM34275), compatible with resuscitators Ref. 34244, 34245, 34277, 34200, 34230 and 34240, as well as with bags from the brands AMBU, Laerdal and TecnoGaz. For resuscitator Ref. 34200, this bag must be used together with valve 34279. No validated 1:1 equivalent with valves from other manufacturers has been found in reliable sources; compatibility is confirmed only with the codes indicated. Complete the set with other accessories from the same family: rear intake valve (34256), autoclavable non-rebreathing valve (34259) and single-use reservoirs with valve of 1,000 and 2,500 ml (34257 and 34258).
Selection tips and variants of interest
Always check the reference of your resuscitator: the GM34279 valve is necessary when you wish to attach the 2,500 ml reservoir bag (GM34275) to equipment such as Ref. 34200. Check the condition of the valve before each use —wear, deformation or loss of tightness— and replace it with the original spare part at any sign of deterioration so as not to compromise the oxygen supply during resuscitation. If your set uses single-use reservoirs, consider the models with integrated valve 34257 (1,000 ml) and 34258 (2,500 ml); for reusable equipment, combine this valve with the reservoir bag 34275. For large orders you can request a quote: contact the technical-commercial department of Cahnos for availability, volume conditions and delivery times.





Reviews
There are no reviews yet.