Description
1. Commercial Introduction
The Sonicaid thermal paper block reference 0553164 is the recording consumable that keeps the cardiotocographs (CTG) of the Sonicaid / Huntleigh family operational: MERIDIAN 800, FM 800 (Team), BD 4000 and BD 4002. Its Z-fold format of 142×150 mm with 300 sheets per block is designed for continuous recording of fetal heart rate (FHR) and uterine activity (IUP) during antepartum monitoring and labour, in delivery rooms, obstetric clinics and maternal-fetal medicine units.
The presentation in a box of 20 blocks allows planned and cost-effective replenishment, avoiding service interruptions. It reproduces the construction of the original technical reference 8400-8003 and is available with delivery in 24/72 h; request a formal quotation for institutional orders and tenders.
2. Technical Explanation
Sonicaid / Huntleigh cardiotocographs record on thermochemical paper: the image is generated by contact of the thermal head on the heat-sensitive layer of the paper, without the need for ink, toner or ribbon. For the recording to be clinically interpretable, the paper must be fed continuously and stably; the Z-fold (z-fold) format facilitates this feeding, prevents jams and allows subsequent archiving of the trace in the clinical record.
This block is thermal paper without pre-printed grid (plain, no grid), as required by the recorders of these series, in which the reference scale is generated by the monitor’s own software. Its grammage and thermal sensitivity are adjusted to the original head to guarantee sharp, stable and durable traces (trace expiry of up to 5 years under adequate archiving conditions), preserving the integrity of the clinical document.
3. Technical Specifications
| Characteristic | Technical detail |
|---|---|
| Reference Cahnos (SKU) | 0553164 |
| Technical reference / OEM | 8400-8003 (Sonicaid / Huntleigh) |
| Equipment brand | Sonicaid (Huntleigh; currently Arjo) |
| Compatible models | MERIDIAN 800, FM 800 (Team), BD 4000, BD 4002 |
| Sheet dimensions | 142 mm (width) × 150 mm (length); factory nominal 143 × 150 mm |
| Capacity | 300 sheets per block (approx. 45 linear metres) |
| Format | Z-fold thermal paper without grid |
| Paper type | High-sensitivity thermochemical (thermal) |
| Print technology | Direct thermal head (without ink, toner or ribbon) |
| Application | Fetal cardiotocography (CTG): FHR and IUP, antepartum monitoring and labour |
| Commercial presentation | Box of 20 blocks |
| Trace shelf life | 5 years after printing (see product instructions) |
| Storage | 5 °C – 40 °C, cool and dry place; avoid direct sunlight and excessive humidity |
4. Equivalences and Cross-References
The technical reference 8400-8003 is the numbering of the equipment manufacturer itself (Sonicaid / Huntleigh, now Arjo Inc.) for the CTG z-fold paper of 143×150 mm without grid, consistently confirmed in catalogues of recording paper manufacturers and authorised distributors. However, there is no official equivalence table published by Huntleigh / Arjo that authorises third-party consumables for this reference; the following references are offered as verified functional comparisons and must be confirmed with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| PCI (recording paper manufacturer, USA) | Medical Cardiology Recording Chart Paper 8400-8003 · 143 mm × 148 ft · z-fold · without grid | 8400-8003 (item PCI) | Comparable by category (not interchangeable 1:1) | Same z-fold format 143 mm × 148 ft (≈300 sheets of 150 mm) without grid, medical grade quality for Sonicaid; presentation in a box of 20. Confirmed in the manufacturer’s catalogue. |
| Precision Charts (USA) | Sonicaid Thermal Paper 143 mm × 148 ft · Z-Fold Array · without grid | 46-1-8003 | Comparable by category (not interchangeable 1:1) | Same dimensions and folding; block without grid for Sonicaid fetal monitors, 20 packs per box. Confirmed in an authorised distributor’s catalogue. |
| Clinical Health Products (CHPmed, USA) | ECG / EEG Recording Paper for Sonicaid 143 mm × 148 ft · z-fold | 8400-8003 (item CHPmed) | Comparable by category (not interchangeable 1:1) | Same format and declared equivalence reference to Sonicaid; distributed in the USA by McKesson (code 914894). Without grid. Confirmed in distribution catalogues. |
| Arjo Inc. (current owner of the Huntleigh / Sonicaid brand) | Fetal Diagnostic Monitor Recording Paper · Huntleigh Thermal Paper · z-fold without grid · box of 20 | ACC-8400-8003-CS | Comparable by category (not interchangeable 1:1) | Official reference of the Huntleigh family with the same base P/N 8400-8003 in a box presentation of 20; verify batch and factory marking before replacing. Confirmed in distribution catalogue. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The OEM reference associated with this block is 8400-8003 (Sonicaid / Huntleigh, now Arjo), corresponding to CTG thermal z-fold paper of 143×150×300 sheets without grid. In the Cahnos catalogue, the same physical format is marketed as 0553164, and the Huntleigh BD4000 / BD4002 family also appears under the internal reference 0992001; it is advisable to confirm the current numbering with the manufacturer or its technical service before formalising the order.
5. Selection tips and variants of interest
Verify the exact model of your equipment: this block is designed for Sonicaid / Huntleigh MERIDIAN 800, FM 800 (Team), BD 4000 and BD 4002 in 142×150 mm format. Do not confuse it with CTG papers from other fetal monitor families that use other dimensions or pre-printed grid (e.g. Philips / HP AVALON 150×100 mm with grid).
Paper without grid: this reference is plain thermal paper (no grid). Confirm that your monitor generates the scale by software; if your equipment requires a pre-printed grid or scale, the consumable is not interchangeable without prior verification.
Do not confuse block with roll: the Sonicaid family monitors of this series use Z-fold block; if your equipment prints on continuous roll, select the corresponding roll reference from our family of thermal papers.
Variants of the same family in Cahnos: CTG z-fold paper for Huntleigh BD4000 / BD4002 (internal ref. 0992001, 143×150×300 without grid); fetal block for Philips / HP AVALON FM-20 / FM-30 with red grid (ref. 0553174, equivalent M1910A) and with green grid (ref. 0553079, equivalent M1911A).
Storage: store the blocks in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the quality of the trace and the stability of the clinical archive. For institutional orders or tenders, contact our technical-commercial department to confirm compatibility and supply conditions.




Reviews
There are no reviews yet.