Description
1. Product Presentation
The ECG thermal paper pad for the Siemens SICARD 460 electrocardiograph is the recording consumable that guarantees sharp, stable and archivable traces on SICARD 460 series equipment. Its Z-fold format of 148 × 100 mm with 400 sheets per pad and orange grid is designed for continuous recording capture in cardiology clinics, emergency departments, occupational medicine and diagnostic units. Marketed under the reference Cahnos 0553113, it reproduces the construction of the original factory consumable 9658535 E100E, so it can be used as a direct replacement for the original paper. Supplied in a box of 20 units with immediate dispatch (24-72 h), it is the replenishment solution that ensures the continuity of care for your service.
2. Technical explanation of the equipment and procedure
The Siemens SICARD 460 electrocardiograph records the electrical activity of the heart using a direct thermal printing system: the image is generated by contact of the hot print head on the heat-sensitive layer of the paper, without the need for ink, toner or ribbon. The quality of the trace therefore depends on the thermal sensitivity of the paper, its grammage and the correct orientation of the pad: the Z-fold format feeds the sheets continuously, which facilitates loading the equipment and subsequent archiving of the recording.
The pre-printed orange grid allows the clinician to accurately measure amplitudes (mV), intervals (PR, QT, RR) and recording speeds (mm/s) directly on the paper, while the print head prints the patient’s signal and identification data on each trace. The use of verified quality paper prevents jams, ghost prints and premature fading of the image in the clinical record.
3. Technical Specifications
| Compatible equipment model | Siemens SICARD 460 (electrocardiograph with thermal recorder) |
| Manufacturer OEM reference | 9658535 / E100E · documented in distribution with EAN 4250123601066 |
| Factory reference (master catalogue) | 29.148.00 (LESSA / AB Medica Group) · alternative OEM 96.58.550 |
| SKU / Commercial reference Cahnos | 0553113 · line code 7967 (internal, not a manufacturer code) |
| Block dimensions | 148 mm × 100 mm |
| Capacity | 400 sheets per block |
| Grid colour | Orange |
| Format | Z-fold thermal paper (block) |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 units (blocks) |
| Application | Electrocardiographic (ECG) and medical recording on equipment with a thermal printhead compatible with its grammage |
| Classification | Class I medical device (recording paper with measuring function) · CE · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC |
| Trace preservation | Approx. 5 years after printing, under normal archival conditions |
| Recommended storage | Cool, dry place, 5 °C – 40 °C, protected from direct sunlight |
4. Equivalences and Cross-References
The OEM reference 9658535 for the Siemens SICARD 460 paper is consistently documented by European manufacturers and distributors of medical recording paper (Diagramm Halbach, Rennecke-Medic, megro, medicshop, Schubert24), with EAN 4250123601066 and Z-fold format of 148 × 100 mm × 400 sheets. The following equivalences should be understood as functional comparisons confirmed in manufacturer and authorised distribution catalogues, not as an official equivalence table published by the equipment manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Siemens Healthineers (original code) | SICARD 460 ECG paper · 148 × 100 mm × 400 sheets · Z-fold | 9658535 (EAN 4250123601066) | Exact reference equivalence (original manufacturer code) | OEM code consistently documented across multiple authorised distributors; the original carton includes 5 booklets of 400 sheets each. Verify presentation and batch against the box of 20 units for this reference. |
| Diagramm Halbach GmbH & Co. KG (Germany) | ECG paper Siemens Sicard 460 · 148 × 100 mm · 400 sheets | HTN 711700 (art. 140034) | Comparable by category (not interchangeable 1:1) | Same dimensions (148 × 100 mm) and 400 sheets, Z-fold. Grid colour of the batch to be verified: several distributions document this reference with a red grid as opposed to the orange of this pad. Confirm grammage and thermal sensitivity against the equipment data sheet. |
| LESSA / AB Medica Group (Spain) | Siemens SICARD-460 folded paper (OEM 96.58.550) · 148 × 100 × 400 | 29.148.00 (catalogue 2914800) | Comparable by category (not interchangeable 1:1) | Same dimension 148 × 100 mm with 400 sheets and same folded format; the LESSA catalogue with factory reference lists this reference with an orange grid (matching). Archive legibility guaranteed for 12 years according to the paper manufacturer; verify batch and grammage. |
There is no equivalence table validated by the equipment manufacturer for this reference; consult the technical department before use in tenders. The code 7967 accompanying the reference is an internal distribution line code and must not be used as a manufacturer code: the code identifying the consumable is the OEM 9658535 (E100E), confirmed in authorised distribution sources.
5. Selection tips and variants of interest
- Select this pad when your service uses a Siemens SICARD 460 electrocardiograph: always check the sheet width (148 mm), length (100 mm), number of sheets (400), grid colour (orange) and Z-fold format before replacing the consumable; an inappropriate grid or grammage can affect the legibility of the recording and the wear of the thermal print head.
- Within the Siemens family in the Cahnos catalogue, other variants of the same line are available: the pad for CARDIOSTAT 3, 144 × 150 mm, with 400 sheets and orange grid (ref. 0553209), the pad for CARDIOSTAT 31/31S, 104 × 100 mm, with 300 sheets and red grid (ref. 0553078), the roll for SICARD 440, 148 mm × 25 m, with red grid (ref. 0553122), or the MegaCart pad, 210 × 300 mm (ref. 0553081-SM).
- Store the paper in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve trace stability and prevent fogging of the thermosensitive layer. Recording shelf life: approximately 5 years under suitable archiving conditions.
- For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formal quotation.